Re: [OSL | CCIE_Voice] Vol2 Lab6 QOS Configuration
Hi Natan, If the question does not specify anything then what overhead type and how many bytes do we use. Thanks for replying. DA On 11/7/10, natan 2me wrote: > Hi. For the calculation of MLP I would always use 13 and for FRF.12 7 > bytes. I as well used go with 10 for MLP, this is kind of an AVG between > QOS and CM SRND.. But, we should go with QOS. Correct me people if I am > wrong. > > thanks, Natan > > On Sat, Nov 6, 2010 at 1:35 AM, David A wrote: > >> Hi All, >> >> In Vol2 Lab6 we are require to do LLQ between HQ and BR2. No CRTP and >> the link is 1024k >> >> From the solution - priority bandwidth = 224 for 8 calls. >> >> So FR overhead used is 10 bytes >> >> 10 + 40(IP/UDP) + 20 (g729 sample) = 70 * 8 = 560 * 50 pps = 28000 = 28k >> >> 8 calls = 8 * 28 = 224k >> >> From SRND - FR overhead is 4 bytes. >> >> Why is the solution using 10 byte L2 overhead. Can anyone help me >> undestand. >> >> Thanks, >> DA >> ___ >> For more information regarding industry leading CCIE Lab training, please >> visit www.ipexpert.com >> > ___ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com
Re: [OSL | CCIE_Voice] Vol2 Lab6 QOS Configuration
Hi. For the calculation of MLP I would always use 13 and for FRF.12 7 bytes. I as well used go with 10 for MLP, this is kind of an AVG between QOS and CM SRND.. But, we should go with QOS. Correct me people if I am wrong. thanks, Natan On Sat, Nov 6, 2010 at 1:35 AM, David A wrote: > Hi All, > > In Vol2 Lab6 we are require to do LLQ between HQ and BR2. No CRTP and > the link is 1024k > > From the solution - priority bandwidth = 224 for 8 calls. > > So FR overhead used is 10 bytes > > 10 + 40(IP/UDP) + 20 (g729 sample) = 70 * 8 = 560 * 50 pps = 28000 = 28k > > 8 calls = 8 * 28 = 224k > > From SRND - FR overhead is 4 bytes. > > Why is the solution using 10 byte L2 overhead. Can anyone help me > undestand. > > Thanks, > DA > ___ > For more information regarding industry leading CCIE Lab training, please > visit www.ipexpert.com > ___ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com
[OSL | CCIE_Voice] Vol2 Lab6 QOS Configuration
Hi All, In Vol2 Lab6 we are require to do LLQ between HQ and BR2. No CRTP and the link is 1024k >From the solution - priority bandwidth = 224 for 8 calls. So FR overhead used is 10 bytes 10 + 40(IP/UDP) + 20 (g729 sample) = 70 * 8 = 560 * 50 pps = 28000 = 28k 8 calls = 8 * 28 = 224k >From SRND - FR overhead is 4 bytes. Why is the solution using 10 byte L2 overhead. Can anyone help me undestand. Thanks, DA ___ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com