[cctalk] Re: Using Gesswein board with RQDX3

2022-12-22 Thread Paul Koning via cctalk



> On Dec 22, 2022, at 3:30 PM, Lee Gleason via cctalk  
> wrote:
> 
>  I'm using several of these, on PRO380s, and on RQDX3s on MicroVAXes
> and  a BA23 11/73. Lessee, did you create the container file for the
> disk? And make sure it's the same file name used in the command line that 
> starts
> up the service? Did you do the command that tells the service to start
> at system boot time? And, my favorite problem in setting these up - are
> the cables plugged in right on both ends of both cables? I had to span
> the vector space of linear combinations of plug orientations to get it
> to work, since my cables didn't have keyways, and how to plug 'em in was
> not obvious. When it works, it works great. Only problem is that I have
> to pause a bit after powering on the system, to let the automatic file
> backup finish before the 11/73 tries to access it. If you don't get
> anywhere, David Gesswein  is very helpful sorting out problems.

Worth pointing out is that RDxx device sizes on RQDX3 and on the Pro are not 
the same, because the Pro always uses 16 sectors per track even if the device 
has longer tracks.

Also: the device needs to be formatted.

paul




[cctalk] Re: Using Gesswein board with RQDX3

2022-12-22 Thread Lee Gleason via cctalk

 I'm using several of these, on PRO380s, and on RQDX3s on MicroVAXes
and  a BA23 11/73. Lessee, did you create the container file for the
disk? And make sure it's the same file name used in the command line that starts
up the service? Did you do the command that tells the service to start
at system boot time? And, my favorite problem in setting these up - are
the cables plugged in right on both ends of both cables? I had to span
the vector space of linear combinations of plug orientations to get it
to work, since my cables didn't have keyways, and how to plug 'em in was
not obvious. When it works, it works great. Only problem is that I have
to pause a bit after powering on the system, to let the automatic file
backup finish before the 11/73 tries to access it. If you don't get
anywhere, David Gesswein  is very helpful sorting out problems.
--
Lee K. Gleason N5ZMR
Control-G Consultants
lee.glea...@comcast.net



[cctalk] Re: Using Gesswein board with RQDX3

2022-12-21 Thread Mike Loewen via cctalk

On Wed, 21 Dec 2022, Nigel Johnson Ham via cctalk wrote:

I am trying to do the above. ZRQC comes up and says four drives of unknown 
type.


Has anybody done this?  I figure there must be a configuration that needs to 
be done, but found nothing in the documentation to do it.


   Have you tried contacting Dave Gesswein directly? He's usually very 
responsive to questions, and is a DEC guru.


https://www.pdp8online.com/


Mike Loewen mloe...@cpumagic.scol.pa.us
Old Technology  http://q7.neurotica.com/Oldtech/