[ceph-users] Rocksdb ceph bluestore

2019-03-09 Thread Vasiliy Tolstov
Hi, i'm interesting in implementation how ceph store wal in raw block
device in rocksdb?
As i know rocksdb uses fs to put files, i find blobdb in rocksdb code in
utilities does ceph uses it?
Or how ceph uses rocksdb to put kv in raw block device?
___
ceph-users mailing list
ceph-users@lists.ceph.com
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com


Re: [ceph-users] Help with crushmap

2018-12-02 Thread Vasiliy Tolstov
вс, 2 дек. 2018 г., 20:38 Paul Emmerich paul.emmer...@croit.io:

> 10 copies for a replicated setup seems... excessive.
>

I'm try to create golang package for simple key-val store that used ceph
crushmap to distribute data.
For each namespace attach ceph crushmap rule.

>
___
ceph-users mailing list
ceph-users@lists.ceph.com
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com


[ceph-users] Help with crushmap

2018-12-02 Thread Vasiliy Tolstov
Hi, i need help with crushmap
I have
3 regions - r1 r2 r3
5 dc - dc1 dc2 dc3 dc4 dc5
dc1 dc2 dc3 in r1
dc4 in r2
dc5 in r3

Each dc have 3 nodes with 2 disks
I need to have 3 rules
rule1 to have 2 copies on two nodes in each dc - 10 copies total failure
domain dc
rule2 to have 2 copies on two nodes in each region - 6 copies total failure
domain region
rule3 to have 2 copies on two nodes in dc1 failure domain node

How looks crushmap in this case for replicated type?
Thanks.
___
ceph-users mailing list
ceph-users@lists.ceph.com
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com


Re: [ceph-users] list admin issues

2018-10-06 Thread Vasiliy Tolstov
Thanks! Do you have bounce message from google in such case (for
example for my account v.tols...@selfip.ru )
сб, 6 окт. 2018 г. в 17:43, Marc Roos :
>
> Of course it is possible, should be easy to track in log files, looks
> like all messages originate from the same host. Let me know what gmail
> says.
>
>
> Received: from spam1.roosit.eu (spam1.roosit.eu [212.26.193.45])
> by sx.f1-outsourcing.eu (Scalix SMTP Relay 11.4.6.13676)
> via ESMTP; Sat, 06 Oct 2018 15:16:24 +0200 (CEST)
> Received: from pdx1-mailman01.dreamhost.com
> (pdx1-mailman01.dreamhost.com [64.90.62.202])
>
> Received: from spam2.roosit.eu (spam2.roosit.eu [212.19.193.230])
> by sx.f1-outsourcing.eu (Scalix SMTP Relay 11.4.6.13676)
> via ESMTP; Fri, 14 Sep 2018 16:08:13 +0200 (CEST)
> Received: from pdx1-mailman01.dreamhost.com
> (pdx1-mailman01.dreamhost.com [64.90.62.202])
>
> Received: from spam2.roosit.eu (spam2.roosit.eu [212.19.193.230])
> by sx.f1-outsourcing.eu (Scalix SMTP Relay 11.4.6.13676)
> via ESMTP; Thu, 06 Sep 2018 16:23:27 +0200 (CEST)
> Received: from pdx1-mailman01.dreamhost.com
> (pdx1-mailman01.dreamhost.com [64.90.62.202])
> by spam2.roosit.eu (8.14.4/8.14.4) with ESMTP id w86ENNK5048828
> (version=TLSv1/SSLv3 cipher=DHE-RSA-AES256-GCM-SHA384 bits=
>
> Received: from spam2.roosit.eu (spam2.roosit.eu [212.19.193.230])
> by sx.f1-outsourcing.eu (Scalix SMTP Relay 11.4.6.13676)
> via ESMTP; Thu, 06 Sep 2018 14:00:11 +0200 (CEST)
> Received: from pdx1-mailman01.dreamhost.com
> (pdx1-mailman01.dreamhost.com [64.90.62.202])
> by spam2.roosit.eu (8.14.4/8.14.4) with ESMTP id w86C07il043315
>     (version=TLSv1/SSLv3 cipher=DHE-RSA-AES256-GCM-SHA384
>
> -Original Message-
> From: Vasiliy Tolstov [mailto:v.tols...@selfip.ru]
> Sent: zaterdag 6 oktober 2018 16:34
> To: Marc Roos
> Cc: ceph-users@lists.ceph.com; elias.abacio...@deltaprojects.com
> Subject: *SPAM* Re: [ceph-users] list admin issues
>
> сб, 6 окт. 2018 г. в 16:48, Marc Roos :
> >
>
> I have such problems too. And also i have address on gmail (my own
> domain). I'm asked from list admins to provide bounce message to contact
> google team. But after three days nobody answered.
> I don't think that is possible to ask google without message from mailer
> about bounce.
>
> --
> Vasiliy Tolstov,
> e-mail: v.tols...@selfip.ru
>
>


-- 
Vasiliy Tolstov,
e-mail: v.tols...@selfip.ru
___
ceph-users mailing list
ceph-users@lists.ceph.com
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com


Re: [ceph-users] list admin issues

2018-10-06 Thread Vasiliy Tolstov
сб, 6 окт. 2018 г. в 16:48, Marc Roos :
>

I have such problems too. And also i have address on gmail (my own
domain). I'm asked from list admins to provide bounce message to
contact google team. But after three days nobody answered.
I don't think that is possible to ask google without message from
mailer about bounce.

-- 
Vasiliy Tolstov,
e-mail: v.tols...@selfip.ru
___
ceph-users mailing list
ceph-users@lists.ceph.com
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com


Re: [ceph-users] Why rbd rn did not clean used pool?

2018-08-25 Thread Vasiliy Tolstov
Why avoid cache tier? Does this only for erasure or for replicated too?

вс, 26 Авг 2018, 7:42 Konstantin Shalygin :

> > Configuration:
> > rbd - erasure pool
> > rbdtier - tier pool for rbd
> >
> > ceph osd tier add-cache rbd rbdtier 549755813888
> > ceph osd tier cache-mode rbdtier writeback
> >
> > Create new rbd block device:
> > rbd create --size 16G  rbdtest
> > rbd feature disable rbdtest object-map fast-diff deep-flatten
> > rbd device map rbdtest
> >
> > And fill in rbd0 by data (dd, fio and like).
> >
> > Remove rbd block device:
> > rbd device unmap rbdtest
> > rbd rm rbdtest
> >
> > And now pool usage look like:
> >
> > POOLS:
> >  NAMEID USED%USED MAX AVAIL OBJECTS
> >  rbd 9   16 GiB 0   0 B4094
> >  rbdtier 14 104 KiB 0   1.7 TiB5110
>
>
> Avoid cache-tier configurations. Write rbd objects to EC pool directly
> since luminous clients.
>
>
>
> k
>
> ___
> ceph-users mailing list
> ceph-users@lists.ceph.com
> http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com
>
___
ceph-users mailing list
ceph-users@lists.ceph.com
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com


[ceph-users] ceph crushmap question

2018-07-30 Thread Vasiliy Tolstov
Hi. I'm newbie with ceph. I know that i can define custom types in crush map.
And type id 0 used always for devices. But if i specify
type 0 slot

Does i need to specify devices with this name or use predefined name device?
For example:
type 0 device
device 0 osd.0 class hdd
or
type o slot
slot 0 slot1-1 class hdd

My use case - i have udev rules on my servers that maps device with
serial number to specific server slot. So when disk dies i know which
slot needs to be replaced. (In my server led uid to identify disk does
not work). And i want to use my disk names (slot1, slot2 and so)
inside ceph crush map.

-- 
Vasiliy Tolstov,
e-mail: v.tols...@selfip.ru
___
ceph-users mailing list
ceph-users@lists.ceph.com
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com