Re: [ceph-users] Monitors and read/write latency

2015-01-07 Thread Robert LeBlanc
Monitors are in charge of the CRUSH map. When ever there is a change
to the CRUSH map, an OSD goes down, a new OSD is added, PGs are
increased, etc, the monitor(s) builds a new CRUSH map and distributes
it to all clients and OSDs. Once the client has the CRUSH map, it does
not need to contact the monitor for placement or retrieval of an
object because any object's locate can be computed by the
client.[1][2]

Having your monitors on a 1 Gb link may be just fine based on the
number of OSDs you have and what things look like when you are doing
backfills. It is suggested that the monitors have very fast disks as
it makes sure things are committed to disk before sending new maps to
clients/OSDs.

[1] http://ceph.com/docs/master/rados/operations/crush-map/
[2] http://ceph.com/docs/master/architecture/#scalability-and-high-availability

On Tue, Jan 6, 2015 at 1:37 PM, Logan Barfield  wrote:
> Do monitors have any impact on read/write latencies?  Everything I've read
> says no, but since a client needs to talk to a monitor before reading or
> writing to OSDs it would seem like that would introduce some overhead.
>
> I ask for two reasons:
> 1) We are currently using SSD based OSD nodes for our RBD pools.  These
> nodes are connected to our hypervisors over 10Gbit links for VM block
> devices.  The rest of the cluster is on 1Gbit links, so the RBD nodes
> contact the monitors across 1Gbit instead of 1Gbit.  I'm not sure if this
> would degrade performance at all.
>
> 2) In a multi-datacenter cluster a client may end up contacting a monitor
> located in a remote location (e.g., over a high latency WAN link).  I would
> think the client would have to wait for a response from the monitor before
> beginning read/write operations on the local OSDs.
>
> I'm not sure exactly what the monitor interactions are.  Do clients only
> pull the cluster map from the monitors (then ping it occasionally for
> updates), or do clients talk to the monitors any time they write a new
> object to determine what placement group / OSDs to write to or read from?
>
>
> Thank You,
>
> Logan Barfield
> Tranquil Hosting
>
> ___
> ceph-users mailing list
> ceph-users@lists.ceph.com
> http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com
>
___
ceph-users mailing list
ceph-users@lists.ceph.com
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com


[ceph-users] Monitors and read/write latency

2015-01-07 Thread Logan Barfield
Do monitors have any impact on read/write latencies?  Everything I've read
says no, but since a client needs to talk to a monitor before reading or
writing to OSDs it would seem like that would introduce some overhead.

I ask for two reasons:
1) We are currently using SSD based OSD nodes for our RBD pools.  These
nodes are connected to our hypervisors over 10Gbit links for VM block
devices.  The rest of the cluster is on 1Gbit links, so the RBD nodes
contact the monitors across 1Gbit instead of 1Gbit.  I'm not sure if this
would degrade performance at all.

2) In a multi-datacenter cluster a client may end up contacting a monitor
located in a remote location (e.g., over a high latency WAN link).  I would
think the client would have to wait for a response from the monitor before
beginning read/write operations on the local OSDs.

I'm not sure exactly what the monitor interactions are.  Do clients only
pull the cluster map from the monitors (then ping it occasionally for
updates), or do clients talk to the monitors any time they write a new
object to determine what placement group / OSDs to write to or read from?


Thank You,

Logan Barfield