hi
You can try taking out the modules and putting them back i have seen that
this do the job most of the timedo this and see if it works ...

Regards
Arun Sharma
""Infotech""  wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> Dear Group
>
> I am having one 6509 switch with 2 sup module cards (one in redudent
mode).
> All of a sudden from past couple of days i am observing that my SUP 1
modules
> status LED is not glowing. Same time my sup2 modules management LED is
> glowing
> RED.  But still my switch is working fine.
> When I give SH MOD command it shows status as ok for all the cards
including
> SUP MODULE 1. For sup mod 2 the status shows as standby. I am also having
> MSFC-2 and PFC cards in the same SUP modules. My both sup modules are
exactly
> identical.
>
> Does that mean that either of mine sup module is faulty. Any mod can fail
at
> any time ???.
>
> How can I verify that my modules are working fine. Does anybody faced
problem
> like this.
>
> many thanks in advance
>
> regds
>
>
> 
> Get free email and a permanent address at http://www.netaddress.com/?N=1
> FAQ, list archives, and subscription info:
http://www.groupstudy.com/list/cisco.html
> Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=6392&t=6384
--
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]



Re: [Re: CAT 6509 urg help required [7:6384]

2001-05-30 Thread Infotech

Thanks for replying. I have already tried this many times. But the status
remains the same. Let me tell you more in details:

on sup1 mod only status LED is not glowing where all 3 LED's are gree.
on sup2(redudent) mod status LED is Orange , system LED is green , 3rd LED is
not glowing and 4ht is RED.

what else can u suggest...

regds



"Arun"  wrote:
hi
You can try taking out the modules and putting them back i have seen that
this do the job most of the timedo this and see if it works ...

Regards
Arun Sharma
""Infotech""  wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> Dear Group
>
> I am having one 6509 switch with 2 sup module cards (one in redudent
mode).
> All of a sudden from past couple of days i am observing that my SUP 1
modules
> status LED is not glowing. Same time my sup2 modules management LED is
> glowing
> RED.  But still my switch is working fine.
> When I give SH MOD command it shows status as ok for all the cards
including
> SUP MODULE 1. For sup mod 2 the status shows as standby. I am also having
> MSFC-2 and PFC cards in the same SUP modules. My both sup modules are
exactly
> identical.
>
> Does that mean that either of mine sup module is faulty. Any mod can fail
at
> any time ???.
>
> How can I verify that my modules are working fine. Does anybody faced
problem
> like this.
>
> many thanks in advance
>
> regds
>
>
> 
> Get free email and a permanent address at http://www.netaddress.com/?N=1
> FAQ, list archives, and subscription info:
http://www.groupstudy.com/list/cisco.html
> Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]
FAQ, list archives, and subscription info:
http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]



Get free email and a permanent address at http://www.netaddress.com/?N=1




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=6397&t=6384
--
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]