Transmit underflow error message [7:25110]
Hi All, I have a question ansd would like to know if anyone can help. Cisco states that The error below is nothing to be concerned about and that the system should recover just fine, but it is beginning to occur more frequently and I would like to know if there is anything that can be done. The Fa0/1 is connectd to an Alteon Ace Director 3 and that cat5 cable runs between the router and that device and then the router runs out to the internet. Any suggestions? .Nov 1 15:34:44.977 est: %AMDP2_FE-3-UNDERFLO: AMDP2/FE(0/1), Transmit underflow .Nov 2 13:31:34.024 est: %AMDP2_FE-3-UNDERFLO: AMDP2/FE(0/1), Transmit underflow .Nov 2 13:43:38.648 est: %AMDP2_FE-3-UNDERFLO: AMDP2/FE(0/1), Transmit underflow .Nov 2 13:52:28.366 est: %AMDP2_FE-3-UNDERFLO: AMDP2/FE(0/1), Transmit underflow .Nov 2 13:52:28.370 est: %AMDP2_FE-3-UNDERFLO: AMDP2/FE(0/1), Transmit underflow Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=25110&t=25110 -- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]
RE: Underflow Error
Error Message: %LANCE-3-UNDERFLO Unit [dec], underflow error Explanation: The Ethernet hardware is requesting data faster than the system can supply it. This should never happen unless a serious malfunction has occurred. Recommended Action: Contact Cisco Systems. ( this is from cisco's site and i do not work for cisco :) ) Regards Atif -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]]On Behalf Of Roan, Wayne Sent: Friday, August 18, 2000 9:45 PM To: '[EMAIL PROTECTED]' Subject: Underflow Error Group, Anyone know what the following errors are, and what causes them? 00:08:12: %LANCE-3-UNDERFLO: Unit 1, underflow error 00:10:56: %LANCE-3-UNDERFLO: Unit 0, underflow error 00:38:12: %LANCE-3-UNDERFLO: Unit 1, underflow error 00:44:34: %LANCE-3-UNDERFLO: Unit 0, underflow error 00:50:54: %LANCE-3-UNDERFLO: Unit 1, underflow error 00:53:06: %LANCE-3-UNDERFLO: Unit 0, underflow error 00:55:14: %LANCE-3-UNDERFLO: Unit 1, underflow error 01:21:15: %LANCE-3-UNDERFLO: Unit 0, underflow error 02:18:05: %LANCE-3-UNDERFLO: Unit 0, underflow error 02:21:55: %LANCE-3-UNDERFLO: Unit 1, underflow error 02:21:55: %LANCE-3-UNDERFLO: Unit 1, underflow error 02:26:36: %LANCE-3-UNDERFLO: Unit 1, underflow error Thanks, Wayne ___ UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html FAQ, list archives, and subscription info: http://www.groupstudy.com Report misconduct and Nondisclosure violations to [EMAIL PROTECTED] ___ UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html FAQ, list archives, and subscription info: http://www.groupstudy.com Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]
Underflow Error
Group, Anyone know what the following errors are, and what causes them? 00:08:12: %LANCE-3-UNDERFLO: Unit 1, underflow error 00:10:56: %LANCE-3-UNDERFLO: Unit 0, underflow error 00:38:12: %LANCE-3-UNDERFLO: Unit 1, underflow error 00:44:34: %LANCE-3-UNDERFLO: Unit 0, underflow error 00:50:54: %LANCE-3-UNDERFLO: Unit 1, underflow error 00:53:06: %LANCE-3-UNDERFLO: Unit 0, underflow error 00:55:14: %LANCE-3-UNDERFLO: Unit 1, underflow error 01:21:15: %LANCE-3-UNDERFLO: Unit 0, underflow error 02:18:05: %LANCE-3-UNDERFLO: Unit 0, underflow error 02:21:55: %LANCE-3-UNDERFLO: Unit 1, underflow error 02:21:55: %LANCE-3-UNDERFLO: Unit 1, underflow error 02:26:36: %LANCE-3-UNDERFLO: Unit 1, underflow error Thanks, Wayne ___ UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html FAQ, list archives, and subscription info: http://www.groupstudy.com Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]