VOIP over FR..how can get the tone from opposite PABX..?

2001-03-05 Thread Grad Alfons Kanon

I have scenario to install:

Headquarter (HQ) connect to Branch A (A) and B (B) using Frame Relay
HQ using E&M conect to PABX HQ and Branch A using E&M but Branch B using 
FXO.

We make dial plane like this:

x-111-yyy --> to HQ from the rest
x-222-yyy --> to A from the rest
x-333-yyy --> to B from the rest

x = number that user must dial to get the tone from Voip configured in PABX

yyy = local extension number.

The problem is, when we dial from HQ to Branch A/B, we can only reach the 
user at the opposite site if we dial x-222-yyy / x-333-yyy all at once. We 
can not press x-222 to get the tone from PABX A and then extension number.

How can we configure the router to enable user get the tone from opposite 
PABX after dial 111 or 222 or 333.?

CONFIG in HQ

dial-peer voice 1 pots
destination-pattern 111
port 1/0/0
!
dial-peer voice 222 voip
destination-pattern 222...
session target ipv4:192.168.100.1
!
dial-peer voice 333 voip
destination-pattern 333...
ip precedence 5
session target ipv4:192.168.100.5

voice-port 1/0/0
timing percentbreak 50
operation 4-wire
type 5
signal immediate


regards

Grad
_
Get Your Private, Free E-mail from MSN Hotmail at http://www.hotmail.com.

_
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]



Re: VOIP over FR..how can get the tone from opposite PABX..?

2001-03-05 Thread Igor Glavanic

I have just done the same thing few weeks ago.
Make sure that you have the cables from PBX to E&M interfaces made by the
Cisco specification. You can get the wiring details from the 1700 Series
Hardware installation guide or the web.

Cheers.



_
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]



Re: VOIP over FR..how can get the tone from opposite PABX..?

2001-03-06 Thread Grad Alfons Kanon

Thanks,

I have followed the cable specification from Cisco to E&M interface.
But for the grounding, I stick the E&M grounding to Cisco chasis.

SO, Is there anything left on the config..?

regards

Grad


>From: "Igor Glavanic" <[EMAIL PROTECTED]>
>Reply-To: "Igor Glavanic" <[EMAIL PROTECTED]>
>To: [EMAIL PROTECTED]
>Subject: Re: VOIP over FR..how can get the tone from opposite PABX..?
>Date: Tue, 6 Mar 2001 16:20:43 +1100
>
>I have just done the same thing few weeks ago.
>Make sure that you have the cables from PBX to E&M interfaces made by the
>Cisco specification. You can get the wiring details from the 1700 Series
>Hardware installation guide or the web.
>
>Cheers.
>
>
>
>_
>FAQ, list archives, and subscription info: 
>http://www.groupstudy.com/list/cisco.html
>Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

_
Get Your Private, Free E-mail from MSN Hotmail at http://www.hotmail.com.

_
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]



Re: VOIP over FR..how can get the tone from opposite PABX..?

2001-03-13 Thread [iso-8859-1] Nuurul Basar

[ The following text is in the "iso-8859-1" character set. ]
[ Your display is set for the "US-ASCII" character set.  ]
[ Some characters may be displayed incorrectly. ]

Hai

Have the same problem last time, the tone and rinnging
tone will be intermitten if you dont have the same
grounding for both Router and PABX.

Do have a same grounding point for both PABX and
router.  What i have done is make a temp cable from my
PABX to the cisco chassis and you got tone.  

p/s

good luck

basar
--- Grad Alfons Kanon <[EMAIL PROTECTED]> wrote: >
Thanks,
> 
> I have followed the cable specification from Cisco
> to E&M interface.
> But for the grounding, I stick the E&M grounding to
> Cisco chasis.
> 
> SO, Is there anything left on the config..?
> 
> regards
> 
> Grad
> 
> 
> >From: "Igor Glavanic" <[EMAIL PROTECTED]>
> >Reply-To: "Igor Glavanic" <[EMAIL PROTECTED]>
> >To: [EMAIL PROTECTED]
> >Subject: Re: VOIP over FR..how can get the tone
> from opposite PABX..?
> >Date: Tue, 6 Mar 2001 16:20:43 +1100
> >
> >I have just done the same thing few weeks ago.
> >Make sure that you have the cables from PBX to E&M
> interfaces made by the
> >Cisco specification. You can get the wiring details
> from the 1700 Series
> >Hardware installation guide or the web.
> >
> >Cheers.
> >
> >
> >
> >_
> >FAQ, list archives, and subscription info: 
> >http://www.groupstudy.com/list/cisco.html
> >Report misconduct and Nondisclosure violations to
> [EMAIL PROTECTED]
> 
>
_
> Get Your Private, Free E-mail from MSN Hotmail at
> http://www.hotmail.com.
> 
> _
> FAQ, list archives, and subscription info:
> http://www.groupstudy.com/list/cisco.html
> Report misconduct and Nondisclosure violations to
[EMAIL PROTECTED]


__
Do You Yahoo!?
Yahoo! Auctions - Buy the things you want at great prices.
http://auctions.yahoo.com/

_
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]