Just a quick heads up to a couple of problems I had over the weekend on the
Solie scenarios. Anyway one the routers needed to be set up a having two sub
interfaces, one point-to-point, one multipoint. On the PTP I mapped the
wrong DLCI to it and even though I removed the statement and rebooted, it
would not remove it. I needed to remove the subinterface and reboot then
recreate the subinterface with the correct DLCI. Also I had a problem with
another DLCI not being seen by the spoke router. This router's serial
interface line protocol was also going up down. I suspected missing LMI and
that was the case. It turns out that in recabling for the new lab, I bent
one of the pins on the serial over. Anyway these two things cost some time
so if I can save anyone grief with similar problems great. Otherwise I
learned a few things which is the whole point of this.


Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=42902&t=42902
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to