Package: libsane
Version: 1.0.19-11
Followup-For: Bug #474706

-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA512


Hello Bert,

I've recently acquired an HP ScanJet5300c scanner myself, and ran into
pretty much exactly the same problem. However, after some fiddling
around with /etc/sane.d/avision.conf, I found that uncommenting the
following two lines stops the segfault for me:

option disable-gamma-table
option disable-calibration

For reference, I've attached my avision.conf file which allows me to use
xsane to scan, though there is a long delay whilst it starts up (see
bug #485852). When I was playing around, I seem to remember trying this
once and it failed, but this has now worked several times after various
scanner connects/disconnects and reboots of the PC it's connected to.
It'd be interesting to learn if this works around the problem for you,
too.


- -- System Information:
Debian Release: lenny/sid
  APT prefers unstable
  APT policy: (500, 'unstable'), (500, 'testing')
Architecture: amd64 (x86_64)

Kernel: Linux 2.6.25.4 (SMP w/2 CPU cores)
Locale: LANG=en_GB, LC_CTYPE=en_GB (charmap=ISO-8859-1)
Shell: /bin/sh linked to /bin/bash

Versions of packages libsane depends on:
ii  adduser                      3.108       add and remove users and groups
ii  libavahi-client3             0.6.22-3    Avahi client library
ii  libavahi-common3             0.6.22-3    Avahi common library
ii  libc6                        2.7-12      GNU C Library: Shared libraries
ii  libexif12                    0.6.16-2.1  library to parse EXIF files
ii  libgphoto2-2                 2.4.0-9     gphoto2 digital camera library
ii  libgphoto2-port0             2.4.0-9     gphoto2 digital camera port librar
ii  libieee1284-3                0.2.11-4    cross-platform library for paralle
ii  libjpeg62                    6b-14       The Independent JPEG Group's JPEG 
ii  libsane-extras               1.0.19.7    API library for scanners -- extra 
ii  libtiff4                     3.8.2-8     Tag Image File Format (TIFF) libra
ii  libusb-0.1-4                 2:0.1.12-11 userspace USB programming library
ii  makedev                      2.3.1-88    creates device files in /dev
ii  udev                         0.114-2     /dev/ and hotplug management daemo

Versions of packages libsane recommends:
ii  avahi-daemon                  0.6.22-3   Avahi mDNS/DNS-SD daemon
ii  sane-utils                    1.0.19-11  API library for scanners -- utilit

- -- debconf-show failed

-----BEGIN PGP SIGNATURE-----
Version: GnuPG v1.4.9 (GNU/Linux)
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=SVd9
-----END PGP SIGNATURE-----
# This are the possible options. Normally any scanner
# should work just fine without them - and they are only
# needed for test and debugging. So if you experience problems
# and you solve them with enabling options here, please notify
# the SANE/Avision maintainer: Rene Rebe <[EMAIL PROTECTED]>

option disable-gamma-table
option disable-calibration
#option force-a4

#scsi AVISION
#scsi FCPA
#scsi MINOLTA
#scsi MITSBISH MCA-S600C
#scsi MITSBISH MCA-SS600
#scsi HP
#scsi hp

#scsi /dev/scanner
#usb libusb:002:003
#usb 0x03f0 0x0701

Reply via email to