Public bug reported:

sane-backends (1.0.27-1~experimental3ubuntu2.2) brought a fix for a black 
vertical band on scans
done with e.g. Canon LiDE 100 and 200 scanners on Ubuntu 18.04 as noted here:

   sane-backends (1.0.27-1~experimental3ubuntu2.2) bionic;
urgency=medium

     * debian/patches/git-fix-discolored-bar-issue.patch:
       - Upstream commit to fix issue with discolored bar on Genesys GL847
         scanners (LP: #1731459).

    -- Gunnar Hjalmarsson <gunna...@ubuntu.com>  Thu, 08 Aug 2019
20:27:00 +0200

However, on my Canon LiDE 120 it worked fine before that fix in 18.04, but now 
the image shows
a discolored band at precisely the same location where on an LiDE 100/200 the 
black band
used to be.

See attached test scan for an example and compare with the uploads from
https://bugs.launchpad.net/ubuntu/+source/sane-backends/+bug/1731459 .

Affected are also daily builds of 20.04 from 2020-02-15.

** Affects: sane-backends (Ubuntu)
     Importance: Undecided
         Status: New

** Attachment added: "test scan showing the vertical band"
   
https://bugs.launchpad.net/bugs/1863424/+attachment/5328427/+files/lide120.png

-- 
You received this bug notification because you are a member of Desktop
Packages, which is subscribed to sane-backends in Ubuntu.
https://bugs.launchpad.net/bugs/1863424

Title:
  Regression on Canon LiDE 120 by fix for #1731459

Status in sane-backends package in Ubuntu:
  New

Bug description:
  sane-backends (1.0.27-1~experimental3ubuntu2.2) brought a fix for a black 
vertical band on scans
  done with e.g. Canon LiDE 100 and 200 scanners on Ubuntu 18.04 as noted here:

     sane-backends (1.0.27-1~experimental3ubuntu2.2) bionic;
  urgency=medium

       * debian/patches/git-fix-discolored-bar-issue.patch:
         - Upstream commit to fix issue with discolored bar on Genesys GL847
           scanners (LP: #1731459).

      -- Gunnar Hjalmarsson <gunna...@ubuntu.com>  Thu, 08 Aug 2019
  20:27:00 +0200

  However, on my Canon LiDE 120 it worked fine before that fix in 18.04, but 
now the image shows
  a discolored band at precisely the same location where on an LiDE 100/200 the 
black band
  used to be.

  See attached test scan for an example and compare with the uploads from
  https://bugs.launchpad.net/ubuntu/+source/sane-backends/+bug/1731459 .

  Affected are also daily builds of 20.04 from 2020-02-15.

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/sane-backends/+bug/1863424/+subscriptions

-- 
Mailing list: https://launchpad.net/~desktop-packages
Post to     : desktop-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~desktop-packages
More help   : https://help.launchpad.net/ListHelp

Reply via email to