[Desktop-packages] [Bug 1896842] Re: simple-scan cannot scan a page using EPSON V39 scanner
Thank you for the update, yes, version 3.36.6 works, I confirm. -- You received this bug notification because you are a member of Desktop Packages, which is subscribed to simple-scan in Ubuntu. https://bugs.launchpad.net/bugs/1896842 Title: simple-scan cannot scan a page using EPSON V39 scanner Status in Simple Scan: Unknown Status in simple-scan package in Ubuntu: Fix Committed Bug description: ishabalov@black:~$ simple-scan --debug [+0.00s] DEBUG: simple-scan.vala:1720: Starting simple-scan 3.36.3, PID=38292 [+0.00s] DEBUG: unsetenv() is not thread-safe and should not be used after threads are created [+0.01s] DEBUG: _g_io_module_get_default: Found default implementation dconf (DConfSettingsBackend) for ‘gsettings-backend’ [+0.09s] DEBUG: app-window.vala:1906: Loading state from /home/ishabalov/.cache/simple-scan/state [+0.09s] DEBUG: app-window.vala:1885: Restoring window to 1351x672 pixels [+0.17s] DEBUG: scanner.vala:1539: sane_init () -> SANE_STATUS_GOOD [+0.17s] DEBUG: scanner.vala:1545: SANE version 1.0.29 [+0.17s] DEBUG: scanner.vala:1606: Requesting redetection of scan devices [+0.17s] DEBUG: scanner.vala:828: Processing request [+0.56s] DEBUG: app-window.vala:1981: Saving state to /home/ishabalov/.cache/simple-scan/state [+8.42s] DEBUG: scanner.vala:341: sane_get_devices () -> SANE_STATUS_GOOD [+8.42s] DEBUG: scanner.vala:353: Device: name="imagescan:esci:gt-s650:usb:/sys/devices/pci:00/:00:13.2/usb2/2-5/2-5:1.0" vendor="EPSON" model="Epson_Perfection_V39" type="" [+8.72s] DEBUG: app-window.vala:1981: Saving state to /home/ishabalov/.cache/simple-scan/state [+9.90s] DEBUG: simple-scan.vala:1536: Requesting scan at 300 dpi from device 'imagescan:esci:gt-s650:usb:/sys/devices/pci:00/:00:13.2/usb2/2-5/2-5:1.0' [+9.90s] DEBUG: scanner.vala:1674: Scanner.scan ("imagescan:esci:gt-s650:usb:/sys/devices/pci:00/:00:13.2/usb2/2-5/2-5:1.0", dpi=300, scan_mode=ScanMode.COLOR, depth=8, type=single, paper_width=0, paper_height=0, brightness=26, contrast=46, delay=3000ms) [+9.90s] DEBUG: scanner.vala:828: Processing request [+10.17s] DEBUG: scanner.vala:889: sane_open ("imagescan:esci:gt-s650:usb:/sys/devices/pci:00/:00:13.2/usb2/2-5/2-5:1.0") -> SANE_STATUS_GOOD [+10.17s] DEBUG: scanner.vala:910: sane_get_option_descriptor (0) [+10.17s] DEBUG: scanner.vala:760: Option 0: type=int size=4 cap=soft-detect,advanced [+10.17s] DEBUG: scanner.vala:763: Description: [+10.17s] DEBUG: scanner.vala:910: sane_get_option_descriptor (1) [+10.17s] DEBUG: scanner.vala:760: Option 1: name='device-02-general' title='General' type=group size=0 cap=inactive [+10.17s] DEBUG: scanner.vala:763: Description: Basic options. [+10.17s] DEBUG: scanner.vala:910: sane_get_option_descriptor (2) [+10.17s] DEBUG: scanner.vala:760: Option 2: name='source' title='Document Source' type=string size=15 values=["Document Table"] cap=soft-detect [+10.17s] DEBUG: scanner.vala:763: Description: Document Source [+10.17s] DEBUG: scanner.vala:910: sane_get_option_descriptor (3) [+10.17s] DEBUG: scanner.vala:760: Option 3: name='enable-resampling' title='Enable Resampling' type=bool size=4 cap=soft-detect,inactive,advanced [+10.17s] DEBUG: scanner.vala:763: Description: This option provides the user with a wider range of supported resolutions. Resolutions not supported by the hardware will be achieved through image processing methods. [+10.17s] DEBUG: scanner.vala:910: sane_get_option_descriptor (4) [+10.17s] DEBUG: scanner.vala:760: Option 4: name='resolution' title='Resolution' type=int size=4 unit=dpi min=50, max=4800, quant=0 cap=soft-select,soft-detect [+10.17s] DEBUG: scanner.vala:763: Description: Resolution [+10.17s] DEBUG: scanner.vala:910: sane_get_option_descriptor (5) [+10.17s] DEBUG: scanner.vala:760: Option 5: name='scan-area' title='Scan Area' type=string size=19 values=["Executive/Portrait", "ISO/A4/Portrait", "ISO/A5/Portrait", "ISO/A5/Landscape", "ISO/A6/Portrait", "ISO/A6/Landscape", "JIS/B5/Portrait", "JIS/B6/Portrait", "JIS/B6/Landscape", "Letter/Portrait", "Manual", "Maximum"] cap=soft-select,soft-detect [+10.17s] DEBUG: scanner.vala:763: Description: Scan Area [+10.17s] DEBUG: scanner.vala:910: sane_get_option_descriptor (6) [+10.17s] DEBUG: scanner.vala:760: Option 6: name='mode' title='Image Type' type=string size=11 values=["Monochrome", "Grayscale", "Color"] cap=soft-select,soft-detect,emulated [+10.17s] DEBUG: scanner.vala:763: Description: Image Type [+10.17s] DEBUG: scanner.vala:910: sane_get_option_descriptor (7) [+10.17s] DEBUG: scanner.vala:760: Option 7: name='device-03-geometry' title='Geometry' type=group size=0 cap=inactive [+10.17s] DEBUG: scanner.vala:763: Description: Scan area and image size related options. [+10.17s] DEBUG: scanner.vala:910: sane_get_option_descriptor (8) [+10.17s] DEBUG: scanner.vala:760: Option 8: name='br-x'
[Desktop-packages] [Bug 1896842] Re: simple-scan cannot scan a page using EPSON V39 scanner
The issue was fixed in simple-scan 3.36.6 https://gitlab.gnome.org/GNOME/simple-scan/-/blob/gnome-3-36/NEWS ** Bug watch added: gitlab.gnome.org/GNOME/simple-scan/-/issues #90 https://gitlab.gnome.org/GNOME/simple-scan/-/issues/90 ** Also affects: simple-scan via https://gitlab.gnome.org/GNOME/simple-scan/-/issues/90 Importance: Unknown Status: Unknown ** Changed in: simple-scan (Ubuntu) Status: New => Fix Committed -- You received this bug notification because you are a member of Desktop Packages, which is subscribed to simple-scan in Ubuntu. https://bugs.launchpad.net/bugs/1896842 Title: simple-scan cannot scan a page using EPSON V39 scanner Status in Simple Scan: Unknown Status in simple-scan package in Ubuntu: Fix Committed Bug description: ishabalov@black:~$ simple-scan --debug [+0.00s] DEBUG: simple-scan.vala:1720: Starting simple-scan 3.36.3, PID=38292 [+0.00s] DEBUG: unsetenv() is not thread-safe and should not be used after threads are created [+0.01s] DEBUG: _g_io_module_get_default: Found default implementation dconf (DConfSettingsBackend) for ‘gsettings-backend’ [+0.09s] DEBUG: app-window.vala:1906: Loading state from /home/ishabalov/.cache/simple-scan/state [+0.09s] DEBUG: app-window.vala:1885: Restoring window to 1351x672 pixels [+0.17s] DEBUG: scanner.vala:1539: sane_init () -> SANE_STATUS_GOOD [+0.17s] DEBUG: scanner.vala:1545: SANE version 1.0.29 [+0.17s] DEBUG: scanner.vala:1606: Requesting redetection of scan devices [+0.17s] DEBUG: scanner.vala:828: Processing request [+0.56s] DEBUG: app-window.vala:1981: Saving state to /home/ishabalov/.cache/simple-scan/state [+8.42s] DEBUG: scanner.vala:341: sane_get_devices () -> SANE_STATUS_GOOD [+8.42s] DEBUG: scanner.vala:353: Device: name="imagescan:esci:gt-s650:usb:/sys/devices/pci:00/:00:13.2/usb2/2-5/2-5:1.0" vendor="EPSON" model="Epson_Perfection_V39" type="" [+8.72s] DEBUG: app-window.vala:1981: Saving state to /home/ishabalov/.cache/simple-scan/state [+9.90s] DEBUG: simple-scan.vala:1536: Requesting scan at 300 dpi from device 'imagescan:esci:gt-s650:usb:/sys/devices/pci:00/:00:13.2/usb2/2-5/2-5:1.0' [+9.90s] DEBUG: scanner.vala:1674: Scanner.scan ("imagescan:esci:gt-s650:usb:/sys/devices/pci:00/:00:13.2/usb2/2-5/2-5:1.0", dpi=300, scan_mode=ScanMode.COLOR, depth=8, type=single, paper_width=0, paper_height=0, brightness=26, contrast=46, delay=3000ms) [+9.90s] DEBUG: scanner.vala:828: Processing request [+10.17s] DEBUG: scanner.vala:889: sane_open ("imagescan:esci:gt-s650:usb:/sys/devices/pci:00/:00:13.2/usb2/2-5/2-5:1.0") -> SANE_STATUS_GOOD [+10.17s] DEBUG: scanner.vala:910: sane_get_option_descriptor (0) [+10.17s] DEBUG: scanner.vala:760: Option 0: type=int size=4 cap=soft-detect,advanced [+10.17s] DEBUG: scanner.vala:763: Description: [+10.17s] DEBUG: scanner.vala:910: sane_get_option_descriptor (1) [+10.17s] DEBUG: scanner.vala:760: Option 1: name='device-02-general' title='General' type=group size=0 cap=inactive [+10.17s] DEBUG: scanner.vala:763: Description: Basic options. [+10.17s] DEBUG: scanner.vala:910: sane_get_option_descriptor (2) [+10.17s] DEBUG: scanner.vala:760: Option 2: name='source' title='Document Source' type=string size=15 values=["Document Table"] cap=soft-detect [+10.17s] DEBUG: scanner.vala:763: Description: Document Source [+10.17s] DEBUG: scanner.vala:910: sane_get_option_descriptor (3) [+10.17s] DEBUG: scanner.vala:760: Option 3: name='enable-resampling' title='Enable Resampling' type=bool size=4 cap=soft-detect,inactive,advanced [+10.17s] DEBUG: scanner.vala:763: Description: This option provides the user with a wider range of supported resolutions. Resolutions not supported by the hardware will be achieved through image processing methods. [+10.17s] DEBUG: scanner.vala:910: sane_get_option_descriptor (4) [+10.17s] DEBUG: scanner.vala:760: Option 4: name='resolution' title='Resolution' type=int size=4 unit=dpi min=50, max=4800, quant=0 cap=soft-select,soft-detect [+10.17s] DEBUG: scanner.vala:763: Description: Resolution [+10.17s] DEBUG: scanner.vala:910: sane_get_option_descriptor (5) [+10.17s] DEBUG: scanner.vala:760: Option 5: name='scan-area' title='Scan Area' type=string size=19 values=["Executive/Portrait", "ISO/A4/Portrait", "ISO/A5/Portrait", "ISO/A5/Landscape", "ISO/A6/Portrait", "ISO/A6/Landscape", "JIS/B5/Portrait", "JIS/B6/Portrait", "JIS/B6/Landscape", "Letter/Portrait", "Manual", "Maximum"] cap=soft-select,soft-detect [+10.17s] DEBUG: scanner.vala:763: Description: Scan Area [+10.17s] DEBUG: scanner.vala:910: sane_get_option_descriptor (6) [+10.17s] DEBUG: scanner.vala:760: Option 6: name='mode' title='Image Type' type=string size=11 values=["Monochrome", "Grayscale", "Color"] cap=soft-select,soft-detect,emulated [+10.17s] DEBUG: scanner.vala:763: Description: Image Type [+10.17s] DEBUG: scanner.vala:910: