Hi Manasa,
Here are few comments.
1. In API for vmidipmap pass the values as below.
vmidipmap[0].vmid= , vmidipmap[0].vmip=
2. when you pass the virtualmachineids and vmidipmap then vm primary ip and
secondary
assigned to lb rule.
3.Add test cases to check the existing behaviour is not disturbed by this
feature.
4.In verification please add steps to verify the functionality using traffic.
5.Add test case to check impact on internal load balancing, auto scale load
balancer etc.
Thanks,
Jayapal
On 08-Apr-2014, at 2:33 PM, "Manasa Veloori (3P)"
mailto:manasa.velo...@citrix.com>>
wrote:
Hi ,
I have written test cases for the feature “Configuring LB rules for VM NIC
secondary IPs”
Please review it and provide the comments.
https://cwiki.apache.org/confluence/display/CLOUDSTACK/TestPlan+:Configuring+load+balancing+rules+for+VM+nic+secondary+ips
Thanks,
Manasa