[Drakelist] Please standby
The standby mode on the R4A isn't really electrically standby is it? It seems to be only an audio muting. ___ Drakelist mailing list Drakelist@zerobeat.net http://mailman.zerobeat.net/mailman/listinfo/drakelist
Re: [Drakelist] Please standby
I always assumed it was as if it was muted. I believe you still have all the plate and screen voltages. Steve Wedge, W1ES/4 To be is to do - Socrates To do is to be - Plato Do be do be do. - Sinatra All my computers have my signature with various pearls of wisdom appended thereto. -- From: Neil M Califano cchange...@yahoo.com Sent: Saturday, October 29, 2011 5:29 PM To: Drakelist@zerobeat.net Subject: [Drakelist] Please standby The standby mode on the R4A isn't really electrically standby is it? It seems to be only an audio muting. ___ Drakelist mailing list Drakelist@zerobeat.net http://mailman.zerobeat.net/mailman/listinfo/drakelist ___ Drakelist mailing list Drakelist@zerobeat.net http://mailman.zerobeat.net/mailman/listinfo/drakelist
Re: [Drakelist] Please standby
The AVC bus is allowed to float to maximum, effectively cutting off all AVC controlled stages. The front panel FUNCTION switch must be on ON, NB or CAL for the external mute to take effect. -- 73, Garey - K4OAH St Charles, IL Drake 2-B, 2-C/2-NT, 4-A, 4-B, C-Line and TR-4/C Service Supplement CDs www.k4oah.com Neil M Califano wrote: The standby mode on the R4A isn't really electrically standby is it? It seems to be only an audio muting. ___ Drakelist mailing list Drakelist@zerobeat.net http://mailman.zerobeat.net/mailman/listinfo/drakelist