Greetings;
I have an unusual RS-232 communication issue with a K2, and I'm curious if
anyone might have a suggestion.
The K2 sends the "FA" (VFO Freq. A) message as expected when the Port Test
is executed from the menu system. However, the K2 does not respond to RS-232
commands from the PC.
I traced the signal through the K2 serial cable, K2IO RS-232 to TTL board,
and all the way to Controller Board U6 pin 26 (RxD). The signal is getting
there, and looks great on the O-scope; Exactly as a 4800 baud signal should
look. This tells me that the PIC 18C452 is getting a good command
(electrically speaking), but is simply not responding to the command. 
Obviously, I've verified that Port is set to "ON". Are there any other
settings, firmware issues, or anything else that I might not be aware of? 

It seems very strange that the K2 will send the test message with no
problems when the Port Test function is used, but that it won't respond to
commands that are getting to the PIC RX Data pin with no issues.

Any help would be greatly appreciated. 

Thanks,
Jason

--
View this message in context: 
http://elecraft.365791.n2.nabble.com/K2-RS-232-TX-but-no-RX-tp6206473p6206473.html
Sent from the Elecraft mailing list archive at Nabble.com.
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html