Re: [Elecraft] K3 Problem in Assembly, need advice

2013-05-18 Thread Twan at pa0kv.nl

Hi Brian,

this measure point is the output terminal of a 5V voltage regulator (U12 
MC7805ACT).
A value of 445 ohms is not alarming. A matter of tolerances in all parts 
connected to this point.

But I expect Elecraft will react too.

73s,   Twan - PA0KV


Message: 14
Date: Sat, 18 May 2013 10:32:20 -0400
From: "Brian F. Wruble"
To: Elecraft Reflector
Subject: [Elecraft] K3 Problem in Assembly, need advice
Message-ID:

Content-Type: text/plain; charset=ISO-8859-1

I am assembling K3 s/n 7394.  I have come to the step on page 45, DMM
resistance measurements.  The resistance between a terminal on U12 and
ground measures 445 ohms.  It is supposed to be >500 ohms.  I am using an
accurate Fluke DMM.

What am I looking for?

73 de Brian W3BW


__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html


[Elecraft] K3 Problem in Assembly, need advice

2013-05-18 Thread Brian F. Wruble
I am assembling K3 s/n 7394.  I have come to the step on page 45, DMM
resistance measurements.  The resistance between a terminal on U12 and
ground measures 445 ohms.  It is supposed to be >500 ohms.  I am using an
accurate Fluke DMM.

What am I looking for?

73 de Brian W3BW


*Brian F. Wruble, C.F.A.

*70 is the new 40.*
*
Mail: 1107 Key Plaza, PMB 447 Key West, FL 33040-4077
Summers: P.O.Box 57, 7400 Augustine Herman Highway, Georgetown, MD 21930
eFax  305.768.0278
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html