Re: [Elecraft] VOX Sensitivity for K2

2018-08-21 Thread Don Wilhelm

Ted,

Which Heil Proset are you using?  There are basicly two types - those 
with an electret mic element and those with a dynamic mic element.  The 
Proset-K2 and the Proset-iC have electret mics while the others have the 
dynamic.  Look at the pivot button for the microphone arm to see which 
type you have.


Your setting is usually fine for the dynamic microphones, but with the 
electret mics usually only need SSBA set to 1.


73,
Don W3FPR

On 8/18/2018 11:20 PM, Dauer, Edward wrote:

Is there a procedure for reducing the VOX sensitivity in the K2?  I have found 
nothing in the Manual or in the Menu menu.  I am using a Heil Proset.  The VOX 
triggers when I let a pen drop on the desk . . .   I believe I am using the 
recommended SSB settings - SSB-A at 2 and SSB-C at 3-1.  Any advice?

__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com


[Elecraft] VOX Sensitivity for K2

2018-08-18 Thread Dauer, Edward
Is there a procedure for reducing the VOX sensitivity in the K2?  I have found 
nothing in the Manual or in the Menu menu.  I am using a Heil Proset.  The VOX 
triggers when I let a pen drop on the desk . . .   I believe I am using the 
recommended SSB settings - SSB-A at 2 and SSB-C at 3-1.  Any advice?

Tnx,

Ted, KN1CBR