Roy,
Be certain you have T-R set to HOLD. See page 89 of the manual. The
T-R setting determines the delay, and the 8R hold or normal settings
will influence the behavior of the 8R signal (that signal controls the
K2 "keyout" timing.
At what code speeds - yes at slow speeds, the relays will "chatter" no
matter what the settings, but at 20+ wpm, the relays should hold in
between characters.
The K2 uses silent electronic T/R switching, but the XVxxx transverters
use relays for T/R functions.
73,
Don w3FPR
On 4/2/2011 1:11 AM, Leroy Marion wrote:
>I just finished a XV50 transverter. Using it with a K2
>
> with the KI02 control.
>
>It seems to work OK when keyed for SSB. When I use
>
> CW, its relays click and chatter like mad. Do I have
>
> some thing set wrong?
>
>
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html