[PSES] General Product Safety Directive

2014-01-28 Thread Scott Xe
Hi

Is this directive applicable to all products?  If the product complies with
the standard listed in OJ, the product is considered in compliance with
GPSD?

If I cannot find any relevant harmonised product specific standard for
verification, how can the supplier demonstrate the product in compliance
with GPSD?

Best regards,

Scott

-

This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 


All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at 
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used 
formats), large files, etc.

Website:  http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas 
Mike Cantwell 

For policy questions, send mail to:
Jim Bacher:  
David Heald: 


Re: [PSES] SV: [PSES] UK plug

2014-01-28 Thread Paul Hesp
>From previous experience the way we did things was to measure the plug pin
dimensions in accordance with Figure 4a) of BS1363-1.

Also, where an Isolated Shutter Opening Device  (ISOD) is used the
appropriate tests were applied.

It is  also quite useful to have the gauge for plug pins as detailed in
Figure 5 of BS 1363-1. This is beneficial in allowing a quick check to see
if the general pin dimensions are correct.

Regards
Paul Hesp
Senior Safety Engineer



-Original Message-
From: John Woodgate [mailto:j...@jmwa.demon.co.uk] 
Sent: 28 January 2014 07:08
To: EMC-PSTC@LISTSERV.IEEE.ORG
Subject: Re: [PSES] SV: [PSES] UK plug

In message <002d01cf1bf4$a18127c0$e4837740$@dk>, dated Tue, 28 Jan 2014, Kim
Boll Jensen  writes:

>So my concern is to find the right parts of BS 1363 or a separate 
>standard that addresses the plug of a wall-plug type equipment.

There isn't one. The only thing you can do is to make sure that any
provision in BS 1363-1 that can be applied to your product is satisfied.
--
OOO - Own Opinions Only. With best wishes. See www.jmwa.demon.co.uk Nondum
ex silvis sumus John Woodgate, J M Woodgate and Associates, Rayleigh, Essex
UK

-

This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to


All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at
http://product-compliance.oc.ieee.org/ can be used for graphics (in
well-used formats), large files, etc.

Website:  http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to
unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas 
Mike Cantwell 

For policy questions, send mail to:
Jim Bacher:  
David Heald: 

-

This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 


All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at 
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used 
formats), large files, etc.

Website:  http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas 
Mike Cantwell 

For policy questions, send mail to:
Jim Bacher:  
David Heald: