RE: Compliance test configuration

2003-09-03 Thread ravinder.ajm...@hgst.com

Hello Rachid, 

Thank you very much for your reply.  In this case, the EUT is the disk drive,
which is connected to SCSI Adapter through the SCSI interface.  The 64-bit
interface is strictly between the PC and the SCSI Adapter, and does not affect
the transfer rate between Adapter and the disk drive.  The only benefit of
using 64-bit interface is to sustain the data rate when connected to a large
number of disk drives.  I would assume that as long as I am transferring data
between Adapter and the disk drive at the maximum transfer rate, the type of
interface between Adapter and PC (both of which are already agency approved)
should not matter.

Regards, Ravinder
Server PCB and Flex Development
Hitachi Global Storage Technologies

Email: ravinder.ajm...@hgst.com








Rachid Sehb rs...@rheintech.com 


09/03/2003 05:34 PM 

To:'ravinder.ajm...@hgst.com' ravinder.ajm...@hgst.com 
cc: 
From:Rachid Sehb rs...@rheintech.com 
Subject:RE: Compliance test configuration 






Hello Ajmani, 
  
In most cases the standard would like the worst case to be tested, so my
advice would be to test the 64 bits. 
  
  

 


Rachid Sehb   EMC engineer mailto:rs...@rheintech.com
mailto:rs...@rheintech.com 


Rhein Tech Laboratories, Inc.   http://www.rheintech.com/
http://www.rheintech.com 


Electro Magnetic Engineering and Testing,  Wireless Testing, Electrical Safety
Testing,  PCB and Hardware Design Engineering 


360 Herndon Parkway, Suite 1400, Herndon, VA 20170 


Tel: 703-689-0368 x127 ; Fax: 703-689-2056 


The information contained in this electronic mail message is privileged and
confidential, and is intended only for use of the addressee. If you are not
the intended recipient, you are hereby notified that any disclosure,
reproduction, distribution or other use of this communication is strictly
prohibited. If you have received this communication in error, please notify
the sender by reply transmission and delete the message without copying or
disclosing it. 



From: ravinder.ajm...@hgst.com [mailto:ravinder.ajm...@hgst.com]
Sent: Wednesday, September 03, 2003 3:08 PM
To: 'emc-p...@majordomo.ieee.org'
Subject: Compliance test configuration


Hi EMC Experts, 


I want to test a U320 SCSI disk drive for agency compliance.  All the U320
SCSI Host Bus Adapters require 64-bit PCI slot, although they will also work
in the 32-bit slot. 


My question is do I have to use a PC with 64-bit PCI bus for my testing (these
PCs are hard to come by), or can I use a PC with 32-bit PCI bus. 


I will appreciate your advice in helping me decide this.

Regards, Ravinder
Server PCB and Flex Development
Hitachi Global Storage Technologies

Email: ravinder.ajm...@hgst.com








Compliance test configuration

2003-09-03 Thread ravinder.ajm...@hgst.com

Hi EMC Experts, 

I want to test a U320 SCSI disk drive for agency compliance.  All the U320
SCSI Host Bus Adapters require 64-bit PCI slot, although they will also work
in the 32-bit slot. 


My question is do I have to use a PC with 64-bit PCI bus for my testing (these
PCs are hard to come by), or can I use a PC with 32-bit PCI bus. 


I will appreciate your advice in helping me decide this.

Regards, Ravinder
Server PCB and Flex Development
Hitachi Global Storage Technologies

Email: ravinder.ajm...@hgst.com