[Freesurfer] mri_convert --out_orientation with inhomogeneous volumes

2007-12-16 Thread Ray Fix

Dear FS Listers,

mri_convert isn't giving me quite what I expected when I use it to  
reorient an inhomogeneous volume.  I apologize in advance if it is my  
misunderstanding or something that has been covered before.  These  
orientation issues make my head spin (as they do the subject data ;-).


Consider the following example:


% mri_info volume.mgz
:
dimensions: 256 x 256 x 128
voxel sizes: 1., 1., 1.3300
:
Orientation   : PIL
Primary Slice Direction: sagittal
:




I take this volume and reorient it with mri_convert to LIA orientation.


% mri_convert --out_orientation LIA volume.mgz volume_LIA.mgz



But what it gives me back is unexpected.


% mri_info volume_LIA.mgh
:
dimensions: 256 x 256 x 128
voxel sizes: 1., 1., 1.3300
:
Orientation   : LIA
Primary Slice Direction: coronal



I was first surprised first that mri_convert was resorting to  
trilinear interpolation.  It seems like this kind of transformation  
could be done with 100% fidelity using nearest neighbor.  But the  
bigger concern is I would have also expected the output dimensions to  
be 128x256x256 with the voxel sizes 1.33, 1.00, 1.00.  It seems like  
if you reorient a non cubic volume with mri_convert, it arbitrarily  
cuts some of the data out from the posterior and anterior.  tkmedit  
display seems to confirm this.


To put it another way,  I would expect:


mri_convert --out_orientation PIL volume_LIA.mgz volume_PIL.mgz



to generate at volume_PIL.mgz file that was voxel identical to the  
original volume.mgz.


Thanks for your time.

Ray


___
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer

Re: [Freesurfer] mri_convert --out_orientation with inhomogeneous volumes

2007-12-16 Thread Doug Greve


did you look at the help for mri_convert concerning the orientation?



On Sun, 16 Dec 2007, Ray Fix wrote:


Dear FS Listers,

mri_convert isn't giving me quite what I expected when I use it to reorient 
an inhomogeneous volume.  I apologize in advance if it is my misunderstanding 
or something that has been covered before.  These orientation issues make my 
head spin (as they do the subject data ;-).


Consider the following example:


% mri_info volume.mgz
:
dimensions: 256 x 256 x 128
voxel sizes: 1., 1., 1.3300
:
Orientation   : PIL
Primary Slice Direction: sagittal
:




I take this volume and reorient it with mri_convert to LIA orientation.


% mri_convert --out_orientation LIA volume.mgz volume_LIA.mgz



But what it gives me back is unexpected.


% mri_info volume_LIA.mgh
:
dimensions: 256 x 256 x 128
voxel sizes: 1., 1., 1.3300
:
Orientation   : LIA
Primary Slice Direction: coronal



I was first surprised first that mri_convert was resorting to trilinear 
interpolation.  It seems like this kind of transformation could be done with 
100% fidelity using nearest neighbor.  But the bigger concern is I would have 
also expected the output dimensions to be 128x256x256 with the voxel sizes 
1.33, 1.00, 1.00.  It seems like if you reorient a non cubic volume with 
mri_convert, it arbitrarily cuts some of the data out from the posterior and 
anterior.  tkmedit display seems to confirm this.


To put it another way,  I would expect:


mri_convert --out_orientation PIL volume_LIA.mgz volume_PIL.mgz



to generate at volume_PIL.mgz file that was voxel identical to the original 
volume.mgz.


Thanks for your time.

Ray





--
Douglas N. Greve, Ph.D.
MGH-NMR Center
[EMAIL PROTECTED]
Phone Number: 617-724-2358 
Fax: 617-726-7422


In order to help us help you, please follow the steps in:
surfer.nmr.mgh.harvard.edu/fswiki/BugReporting