Re: [Freesurfer] recon-all steps specified into volume and surface based stream?

2013-07-18 Thread Douglas N Greve
everything upto the tesselation is the volume-based stream. You can also 
look in recon-all-status.log for which commands are run when
doug
On 07/17/2013 04:58 PM, Martina Papmeyer wrote:
> Dear FreeSurfer experts,
>
> I was wondering if there is anywhere a table or hint, suggesting which
> particular steps of all the recon-all steps (i.e.
> https://surfer.nmr.mgh.harvard.edu/fswiki/ReconAllDevTable) are part
> of the volume-based or the surface-based stream or both? I also found
> this diagram
> https://surfer.nmr.mgh.harvard.edu/fswiki/ReconAllBlockDiagram but I'm
> unsure if the colours are supposed to give me any clues.
>
> I'm familiar with the broad processing stages of the two streams off
> course but would very much love to understand the details better :)
>
> Thank you very much for your help, Martina
>

-- 
Douglas N. Greve, Ph.D.
MGH-NMR Center
gr...@nmr.mgh.harvard.edu
Phone Number: 617-724-2358
Fax: 617-726-7422

Bugs: surfer.nmr.mgh.harvard.edu/fswiki/BugReporting
FileDrop: https://gate.nmr.mgh.harvard.edu/filedrop2
www.nmr.mgh.harvard.edu/facility/filedrop/index.html
Outgoing: ftp://surfer.nmr.mgh.harvard.edu/transfer/outgoing/flat/greve/

___
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer


The information in this e-mail is intended only for the person to whom it is
addressed. If you believe this e-mail was sent to you in error and the e-mail
contains patient information, please contact the Partners Compliance HelpLine at
http://www.partners.org/complianceline . If the e-mail was sent to you in error
but does not contain patient information, please contact the sender and properly
dispose of the e-mail.



[Freesurfer] recon-all steps specified into volume and surface based stream?

2013-07-17 Thread Martina Papmeyer
Dear FreeSurfer experts,

I was wondering if there is anywhere a table or hint, suggesting which  
particular steps of all the recon-all steps (i.e.  
https://surfer.nmr.mgh.harvard.edu/fswiki/ReconAllDevTable) are part  
of the volume-based or the surface-based stream or both? I also found  
this diagram  
https://surfer.nmr.mgh.harvard.edu/fswiki/ReconAllBlockDiagram but I'm  
unsure if the colours are supposed to give me any clues.

I'm familiar with the broad processing stages of the two streams off  
course but would very much love to understand the details better :)

Thank you very much for your help, Martina

-- 
The University of Edinburgh is a charitable body, registered in
Scotland, with registration number SC005336.


___
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer


The information in this e-mail is intended only for the person to whom it is
addressed. If you believe this e-mail was sent to you in error and the e-mail
contains patient information, please contact the Partners Compliance HelpLine at
http://www.partners.org/complianceline . If the e-mail was sent to you in error
but does not contain patient information, please contact the sender and properly
dispose of the e-mail.