Re: gEDA-user: Tragesym template problem.
Hi Daniel, On Samstag, 19. März 2011, Daniel Ross wrote: Hello, I am trying to fill out the Tragesym template for an ATmega128RFA1, but the script gives me an error when I pass it the CSV file (renamed to a .sch file): error: version attribut missing In the template, I had changed the example version number to 20110319 1, following the format of the template version number. I verified that the CSV file contains a version line. Has anyone out there found a solution to this problem? I am following the tutorial at http://geda.seul.org/wiki/geda:tragesym_tutorial;, using the OpenOffice template. Thanks, Dan. Can you show me the first few lines of the input file? ... and the command you've used. Regards Werner ___ geda-user mailing list geda-user@moria.seul.org http://www.seul.org/cgi-bin/mailman/listinfo/geda-user
Re: gEDA-user: Tragesym template problem.
Last time I saw this error it was because when I saved the file, all text fields were quoted. Ie - instead of version\t01 it read version\t01 or something along those lines. I fixed with vim... :1,$s/\//g Geoff ___ geda-user mailing list geda-user@moria.seul.org http://www.seul.org/cgi-bin/mailman/listinfo/geda-user
Re: gEDA-user: Tragesym template problem.
On Sat, Mar 19, 2011 at 4:55 PM, Stefan Salewski m...@ssalewski.de wrote: On Sat, 2011-03-19 at 15:57 -0700, Daniel Ross wrote: Hello, I am trying to fill out the Tragesym template for an ATmega128RFA1, but the script gives me an error when I pass it the CSV file (renamed to a .sch file): error: version attribut missing In the template, I had changed the example version number to 20110319 1, following the format of the template version number. I verified that the CSV file contains a version line. Has anyone out there found a solution to this problem? I am following the tutorial at http://geda.seul.org/wiki/geda:tragesym_tutorial;, using the OpenOffice template. Thanks, Dan. Hm -- have not used tragesym for more than a year. Tragesym is fine, but I do not like the documentation. Please note, input to tragesym is plain text. I really wonder why they advertise use of spreadsheet, I have always used a plain text editor. (OK, spreadsheet may be fine if you try to copy from pdf datasheet...) Do not call tragesym input .sch, that is for schematics. I used .txt extension, it is plain text. The version should be not current date, if I remember correctly, but something related with gschem version. I think that version is copied to symbols, if it is to high, gschem may refuse loading the symbol. My final guess: There may be something wrong with your input file for tragesym, maybe in front of version line. Watch in a plain text editor. You may find working tragesym input files for testing at www.gedasymbols.org. Or fill in tragesym's template.txt with a text editor, leaving version line unchanged. Of course, some people prefer djboxsym, available at www.gedasymbols.org. But tragesym is fine for me. ___ geda-user mailing list geda-user@moria.seul.org http://www.seul.org/cgi-bin/mailman/listinfo/geda-user DJBoxsym looks perfect, I didn't know it existed! Thank you! ___ geda-user mailing list geda-user@moria.seul.org http://www.seul.org/cgi-bin/mailman/listinfo/geda-user
gEDA-user: Tragesym template problem.
Hello, I am trying to fill out the Tragesym template for an ATmega128RFA1, but the script gives me an error when I pass it the CSV file (renamed to a .sch file): error: version attribut missing In the template, I had changed the example version number to 20110319 1, following the format of the template version number. I verified that the CSV file contains a version line. Has anyone out there found a solution to this problem? I am following the tutorial at http://geda.seul.org/wiki/geda:tragesym_tutorial;, using the OpenOffice template. Thanks, Dan. ___ geda-user mailing list geda-user@moria.seul.org http://www.seul.org/cgi-bin/mailman/listinfo/geda-user
Re: gEDA-user: Tragesym template problem.
On Sat, 2011-03-19 at 15:57 -0700, Daniel Ross wrote: Hello, I am trying to fill out the Tragesym template for an ATmega128RFA1, but the script gives me an error when I pass it the CSV file (renamed to a .sch file): error: version attribut missing In the template, I had changed the example version number to 20110319 1, following the format of the template version number. I verified that the CSV file contains a version line. Has anyone out there found a solution to this problem? I am following the tutorial at http://geda.seul.org/wiki/geda:tragesym_tutorial;, using the OpenOffice template. Thanks, Dan. Hm -- have not used tragesym for more than a year. Tragesym is fine, but I do not like the documentation. Please note, input to tragesym is plain text. I really wonder why they advertise use of spreadsheet, I have always used a plain text editor. (OK, spreadsheet may be fine if you try to copy from pdf datasheet...) Do not call tragesym input .sch, that is for schematics. I used .txt extension, it is plain text. The version should be not current date, if I remember correctly, but something related with gschem version. I think that version is copied to symbols, if it is to high, gschem may refuse loading the symbol. My final guess: There may be something wrong with your input file for tragesym, maybe in front of version line. Watch in a plain text editor. You may find working tragesym input files for testing at www.gedasymbols.org. Or fill in tragesym's template.txt with a text editor, leaving version line unchanged. Of course, some people prefer djboxsym, available at www.gedasymbols.org. But tragesym is fine for me. ___ geda-user mailing list geda-user@moria.seul.org http://www.seul.org/cgi-bin/mailman/listinfo/geda-user