[gmx-users] testing Tip5p water
Dear all, a similar problem was proposed in this list in 2002: http://www.gromacs.org/pipermail/gmx-users/2002-August/002339.html I cannot solve my problem, when testing tip5p in gromacs. T( c) density((g/cm^3) -E(kcal/mol) REF125.0 0.999 9.8676 REF225.0 0.984 9.682 my results 25.0 0.984 -7.907 (data published (REF1:JCP 112, p8910 (2000)), REF2: J. Chem. Phys. 117(19):8892-8897. (2002)) ) I want to what results in the big difference above. my main parameters: a.512 water molecules in NVT system from 1ns average collections after 1ns equilibrium. integrator = md dt = 0.001 nstlist = 10 ns_type = grid pbc = xyz rlist= 1 coulombtype = PME rcoulomb = 1.0 vdwtype = cut-off rvdw = 1.22 DispCorr = Ener ; fourierspacing = 0.12 pme_order= 6 Tcoupl = Berendsen tau_t= 0.5 ref_t= 298 Thanks a lot in advance! Yusong // PS: here is md0.log: CPU= 0, lastcg= 127, targetcg= 383, myshift=2 CPU= 1, lastcg= 255, targetcg= 511, myshift=2 CPU= 2, lastcg= 383, targetcg= 128, myshift=2 CPU= 3, lastcg= 511, targetcg= 256, myshift=2 nsb-shift = 2, nsb-bshift= 0 Listing Scalars nsb-nodeid: 0 nsb-nnodes: 4 nsb-cgtotal: 512 nsb-natoms: 2560 nsb-shift: 2 nsb-bshift: 0 Nodeid index homenr cgload workload 0 0 640 128 128 1 640 640 256 256 21280 640 384 384 31920 640 512 512 parameters of the run: integrator = md nsteps = 100 init_step= 0 ns_type = Grid nstlist = 10 ndelta = 2 bDomDecomp = FALSE decomp_dir = 0 nstcomm = 1 comm_mode= Linear nstcheckpoint= 1000 nstlog = 1500 nstxout = 250 nstvout = 250 nstfout = 250 nstenergy= 250 nstxtcout= 1000 init_t = 0 delta_t = 0.001 xtcprec = 1000 nkx = 24 nky = 24 nkz = 21 pme_order= 6 ewald_rtol = 1e-05 ewald_geometry = 0 epsilon_surface = 0 optimize_fft = TRUE ePBC = xyz bUncStart= FALSE bShakeSOR= FALSE etc = Berendsen epc = No epctype = Isotropic tau_p= 1 ref_p (3x3): ref_p[0]={ 0.0e+00, 0.0e+00, 0.0e+00} ref_p[1]={ 0.0e+00, 0.0e+00, 0.0e+00} ref_p[2]={ 0.0e+00, 0.0e+00, 0.0e+00} compress (3x3): compress[0]={ 0.0e+00, 0.0e+00, 0.0e+00} compress[1]={ 0.0e+00, 0.0e+00, 0.0e+00} compress[2]={ 0.0e+00, 0.0e+00, 0.0e+00} andersen_seed= 815131 rlist= 1 coulombtype = PME rcoulomb_switch = 0 rcoulomb = 1 vdwtype = Cut-off rvdw_switch = 0 rvdw = 1.22 epsilon_r= 1 epsilon_rf = 1 tabext = 1 gb_algorithm = Still nstgbradii = 1 rgbradii = 2 gb_saltconc = 0 implicit_solvent = No DispCorr = Ener fudgeQQ = 0.5 free_energy = no init_lambda = 0 sc_alpha = 0 sc_power = 0 sc_sigma = 0.3 delta_lambda = 0 disre_weighting = Conservative disre_mixed = FALSE dr_fc= 1000 dr_tau = 0 nstdisreout = 100 orires_fc= 0 orires_tau = 0 nstorireout = 100 dihre-fc = 1000 dihre-tau= 0 nstdihreout = 100 em_stepsize = 0.01 em_tol = 10 niter= 20 fc_stepsize = 0 nstcgsteep = 1000 nbfgscorr= 10 ConstAlg = Lincs shake_tol= 1e-04 lincs_order = 4 lincs_warnangle = 30 lincs_iter = 1
[gmx-users] how to make choices of COM in the system with freeze group?
Hi, all, I have a system with one carbon Nanotube and lots of water, in which Nanotube is frozen. How do I remove the center-of-mass: 1) only remove the COM of SOL 2) remove both COM of SOL and CNT, separately 3) only remove the COM of system as a whole. 4) do not use any COM How do I make the choices? I use gromacs program 3.3.3 Thank you very much!!! Yusong. ___ gmx-users mailing listgmx-users@gromacs.org http://www.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED] Can't post? Read http://www.gromacs.org/mailing_lists/users.php
RE: [gmx-users] Warning message with 3.3.3 but not with 3.3.1
Even in the system with position-restrain, when only removing com of SOL group, gmx 3.3.3 also give the same error information as Bo: Large VCM(group rest): 0.1, -0.2, -0.0, T-cm: Inf Yusong -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of David van der Spoel Sent: Thursday, April 17, 2008 3:21 AM To: Discussion list for GROMACS users Subject: Re: [gmx-users] Warning message with 3.3.3 but not with 3.3.1 Bo Zhou wrote: Hi gmx-users, I want to simulate a solid/water interface. I just freeze the solid surface, and let the water molecules free to move. Here is a part of my mdp as follows: comm-mode = linear nstcomm = 10 comm-grps = SOL tcoupl = Berendsen tc-grps = SOL Solid tau-t = 0.1 0.1 ref-t = 298 0 Same system and same sets were tested both in gmx 3.3.1 and gmx 3.3.3. Following message in the log file was printed in the log file with gmx 3.3.3, but not with gmx 3.3.1. Large VCM(group rest): 0.1, -0.2, -0.0, T-cm: inf Large VCM(group rest): 0.1, -0.3, -0.0, T-cm: inf Large VCM(group rest): -0.0, -0.3, -0.0, T-cm: inf I wonder whether it is reasonable to stopcm or not. Would it cause any non-physical artifacts? Thanks for suggestions. stopcm tries to change the velocity of the rest group (solid) as well. Unfortunately you can not turn this off for one group. I'm not sure while this is different from 3.3.1, but since you have a solid reference you probably don't need to stopcm. ___ gmx-users mailing listgmx-users@gromacs.org http://www.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED] Can't post? Read http://www.gromacs.org/mailing_lists/users.php -- David. David van der Spoel, PhD, Assoc. Prof., Molecular Biophysics group, Dept. of Cell and Molecular Biology, Uppsala University. Husargatan 3, Box 596, 75124 Uppsala, Sweden phone: 46 18 471 4205 fax: 46 18 511 755 [EMAIL PROTECTED] [EMAIL PROTECTED] http://folding.bmc.uu.se ___ gmx-users mailing listgmx-users@gromacs.org http://www.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED] Can't post? Read http://www.gromacs.org/mailing_lists/users.php ___ gmx-users mailing listgmx-users@gromacs.org http://www.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED] Can't post? Read http://www.gromacs.org/mailing_lists/users.php
RE: [gmx-users] Warning message with 3.3.3 but not with 3.3.1
David wrote: you can not only remove the com motion of one group. it is all (in one or more groups) or nothing. Thank you for replying. Do you mean, that it must be nothing when system has any freeze groups? Yusong. -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of David van der Spoel Sent: Thursday, April 17, 2008 4:01 AM To: Discussion list for GROMACS users Subject: Re: [gmx-users] Warning message with 3.3.3 but not with 3.3.1 tuyusong wrote: Even in the system with position-restrain, when only removing com of SOL group, gmx 3.3.3 also give the same error information as Bo: you can not only remove the com motion of one group. it is all (in one or more groups) or nothing. Large VCM(group rest): 0.1, -0.2, -0.0, T-cm: Inf Yusong -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of David van der Spoel Sent: Thursday, April 17, 2008 3:21 AM To: Discussion list for GROMACS users Subject: Re: [gmx-users] Warning message with 3.3.3 but not with 3.3.1 Bo Zhou wrote: Hi gmx-users, I want to simulate a solid/water interface. I just freeze the solid surface, and let the water molecules free to move. Here is a part of my mdp as follows: comm-mode = linear nstcomm = 10 comm-grps = SOL tcoupl = Berendsen tc-grps = SOL Solid tau-t = 0.1 0.1 ref-t = 298 0 Same system and same sets were tested both in gmx 3.3.1 and gmx 3.3.3. Following message in the log file was printed in the log file with gmx 3.3.3, but not with gmx 3.3.1. Large VCM(group rest): 0.1, -0.2, -0.0, T-cm: inf Large VCM(group rest): 0.1, -0.3, -0.0, T-cm: inf Large VCM(group rest): -0.0, -0.3, -0.0, T-cm: inf I wonder whether it is reasonable to stopcm or not. Would it cause any non-physical artifacts? Thanks for suggestions. stopcm tries to change the velocity of the rest group (solid) as well. Unfortunately you can not turn this off for one group. I'm not sure while this is different from 3.3.1, but since you have a solid reference you probably don't need to stopcm. ___ gmx-users mailing listgmx-users@gromacs.org http://www.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED] Can't post? Read http://www.gromacs.org/mailing_lists/users.php -- David. David van der Spoel, PhD, Assoc. Prof., Molecular Biophysics group, Dept. of Cell and Molecular Biology, Uppsala University. Husargatan 3, Box 596, 75124 Uppsala, Sweden phone: 46 18 471 4205 fax: 46 18 511 755 [EMAIL PROTECTED] [EMAIL PROTECTED] http://folding.bmc.uu.se ___ gmx-users mailing listgmx-users@gromacs.org http://www.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED] Can't post? Read http://www.gromacs.org/mailing_lists/users.php ___ gmx-users mailing listgmx-users@gromacs.org http://www.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED] Can't post? Read http://www.gromacs.org/mailing_lists/users.php
RE: [gmx-users] how to make choices of COM in the system with freeze group?
You can opt for 3). If your system only compose of nanotube and water, why freeze it? Thank Yang Ye, we are doing some tests on effects of T-coupling caused by removing COM in the system with freeze groups Regards, Yusong tuyusong wrote: Hi, all, I have a system with one carbon Nanotube and lots of water, in which Nanotube is frozen. How do I remove the center-of-mass: 1) only remove the COM of SOL 2) remove both COM of SOL and CNT, separately 3) only remove the COM of system as a whole. 4) do not use any COM How do I make the choices? I use gromacs program 3.3.3 Thank you very much!!! Yusong. ___ gmx-users mailing listgmx-users@gromacs.org http://www.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED] Can't post? Read http://www.gromacs.org/mailing_lists/users.php ___ gmx-users mailing listgmx-users@gromacs.org http://www.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED] Can't post? Read http://www.gromacs.org/mailing_lists/users.php ___ gmx-users mailing listgmx-users@gromacs.org http://www.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED] Can't post? Read http://www.gromacs.org/mailing_lists/users.php
RE: [gmx-users] Warning message with 3.3.3 but not with 3.3.1
Bo wrote: Thanks David. So to speak, as the center of mass of group SOL is not free to move, we do not need stopcm to it. Another question is, does it would be problematic in long time simulation without stopcm in such situation, I mean the systematic errors caused by center of mass motion. Thanks for clarification. For a system with freeze group, we should not use any removal of com motions, and this system should still work. I don't find this relevant descriptions in gmx-manual, and it may be added into it. Yusong tuyusong wrote: Even in the system with position-restrain, when only removing com of SOL group, gmx 3.3.3 also give the same error information as Bo: you can not only remove the com motion of one group. it is all (in one or more groups) or nothing. Large VCM(group rest): 0.1, -0.2, -0.0, T-cm: Inf Yusong -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of David van der Spoel Sent: Thursday, April 17, 2008 3:21 AM To: Discussion list for GROMACS users Subject: Re: [gmx-users] Warning message with 3.3.3 but not with 3.3.1 Bo Zhou wrote: Hi gmx-users, I want to simulate a solid/water interface. I just freeze the solid surface, and let the water molecules free to move. Here is a part of my mdp as follows: comm-mode = linear nstcomm = 10 comm-grps = SOL tcoupl = Berendsen tc-grps = SOL Solid tau-t = 0.1 0.1 ref-t = 298 0 Same system and same sets were tested both in gmx 3.3.1 and gmx 3.3.3. Following message in the log file was printed in the log file with gmx 3.3.3, but not with gmx 3.3.1. Large VCM(group rest): 0.1, -0.2, -0.0, T-cm: inf Large VCM(group rest): 0.1, -0.3, -0.0, T-cm: inf Large VCM(group rest): -0.0, -0.3, -0.0, T-cm: inf I wonder whether it is reasonable to stopcm or not. Would it cause any non-physical artifacts? Thanks for suggestions. stopcm tries to change the velocity of the rest group (solid) as well. Unfortunately you can not turn this off for one group. I'm not sure while this is different from 3.3.1, but since you have a solid reference you probably don't need to stopcm. ___ gmx-users mailing listgmx-users@gromacs.org http://www.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED] Can't post? Read http://www.gromacs.org/mailing_lists/users.php -- David. David van der Spoel, PhD, Assoc. Prof., Molecular Biophysics group, Dept. of Cell and Molecular Biology, Uppsala University. Husargatan 3, Box 596, 75124 Uppsala, Sweden phone: 46 18 471 4205 fax: 46 18 511 755 [EMAIL PROTECTED] [EMAIL PROTECTED] http://folding.bmc.uu.se -- ___ gmx-users mailing list gmx-users@gromacs.org http://www.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/search before posting! End of gmx-users Digest, Vol 48, Issue 48 *** ___ gmx-users mailing listgmx-users@gromacs.org http://www.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED] Can't post? Read http://www.gromacs.org/mailing_lists/users.php ___ gmx-users mailing listgmx-users@gromacs.org http://www.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED] Can't post? Read http://www.gromacs.org/mailing_lists/users.php
[gmx-users] how to make choices of COM in the system with freeze group
Hi, Users, I have a system with one carbon Nanotube and lots of water, in which Nanotube is frozen. How do I remove the center-of-mass: 1) only remove the COM of SOL 2) remove both COM of SOL and CNT, separately 2) only remove the COM of system as a whole. How do I make the choices? Thank you very much!!! Yusong. - ___ gmx-users mailing listgmx-users@gromacs.org http://www.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED] Can't post? Read http://www.gromacs.org/mailing_lists/users.php