[gmx-users] Neutralizing the total charge of the system in vacuum

2007-11-24 Thread OZGE ENGIN
Hi all,

I am performing a simulation in vacuum. The peptide has  nonzero charge, so I 
attempted to neutralize the total charge via genion;however as it is known, it 
asks for a continuous group for replacing, but I have no solvent molecules for 
the replacement.

How can I neutralize the total charge while performing simulations in vacuum?

Thanks in advance

Oz.

___
gmx-users mailing listgmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the
www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php


Re: [gmx-users] Neutralizing the total charge of the system in vacuum

2007-11-24 Thread David van der Spoel

Ran Friedman, Biochemisches Inst. wrote:

Hello,

You can add a few ions manually or use genbox. However, it's probably 
better to use a vacuum force field and have your peptide uncharged for 
vacuum simulations. Any ions you add will have a very strong interaction 
with the peptide.


I assume you have a good reason to simulate in vacuo - the mailing list 
archives give many reasons why it's not advised.


It is not advised as a model for peptides in solution, but if you want 
to model something in vacuo then it is fine. In that case you may want 
to look for evidence of the charge of the peptide in vacuo from mass 
spec experiments.

Ran.

On Sat, 24 Nov 2007 19:47:43 +0200
 OZGE ENGIN [EMAIL PROTECTED] wrote:

Hi all,

I am performing a simulation in vacuum. The peptide has  nonzero 
charge, so I attempted to neutralize the total charge via 
genion;however as it is known, it asks for a continuous group for 
replacing, but I have no solvent molecules for the replacement.


How can I neutralize the total charge while performing simulations in 
vacuum?


Thanks in advance

Oz.

___
gmx-users mailing listgmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before 
posting!
Please don't post (un)subscribe requests to the list. Use the www 
interface or send it to [EMAIL PROTECTED]

Can't post? Read http://www.gromacs.org/mailing_lists/users.php


--
Ran Friedman
Postdoctoral Fellow
Computational Structural Biology Group (A. Caflisch)
Institute of Biochemistry
University of Zurich
Winterthurerstrasse 190
CH-8057 Zurich, Switzerland
Tel. +41-44-6354493
Skype: ran.friedman
--

___
gmx-users mailing listgmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the www 
interface or send it to [EMAIL PROTECTED]

Can't post? Read http://www.gromacs.org/mailing_lists/users.php



--
David.

David van der Spoel, PhD, Assoc. Prof., Molecular Biophysics group,
Dept. of Cell and Molecular Biology, Uppsala University.
Husargatan 3, Box 596,  75124 Uppsala, Sweden
phone:  46 18 471 4205  fax: 46 18 511 755
[EMAIL PROTECTED]   [EMAIL PROTECTED]   http://folding.bmc.uu.se

___
gmx-users mailing listgmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to [EMAIL PROTECTED]

Can't post? Read http://www.gromacs.org/mailing_lists/users.php


Re: [gmx-users] Neutralizing the total charge of the system in vacuum

2007-11-24 Thread Ran Friedman, Biochemisches Inst.

Hello,

You can add a few ions manually or use genbox. However, it's probably better 
to use a vacuum force field and have your peptide uncharged for vacuum 
simulations. Any ions you add will have a very strong interaction with the 
peptide.


I assume you have a good reason to simulate in vacuo - the mailing list 
archives give many reasons why it's not advised.


Ran.

On Sat, 24 Nov 2007 19:47:43 +0200
 OZGE ENGIN [EMAIL PROTECTED] wrote:

Hi all,

I am performing a simulation in vacuum. The peptide has  nonzero charge, 
so I attempted to neutralize the total charge via genion;however as it is 
known, it asks for a continuous group for replacing, but I have no solvent 
molecules for the replacement.


How can I neutralize the total charge while performing simulations in 
vacuum?


Thanks in advance

Oz.

___
gmx-users mailing listgmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to [EMAIL PROTECTED]

Can't post? Read http://www.gromacs.org/mailing_lists/users.php


--
Ran Friedman
Postdoctoral Fellow
Computational Structural Biology Group (A. Caflisch)
Institute of Biochemistry
University of Zurich
Winterthurerstrasse 190
CH-8057 Zurich, Switzerland
Tel. +41-44-6354493
Skype: ran.friedman
--

___
gmx-users mailing listgmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the
www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php