Re: Fwd: [gmx-users] Npt equilibration of the membrane-mimicking CCl4 layer

2012-02-17 Thread James Starlight
By the way I also wounder to know how I could keep my system after
equilibration.


E.g I've equilibrated CCl4+water system and obtain stabile system on
desired timescale.

Than I've used genbox to merge my pre-oriented peptide with the
pre-equilibrated system.

genbox -cp peptide_newbox.gro -cs CCl4_water_box.gro -o peptide_in_box.gro



As the consequence I've obtained system with peptide inserted in CCl4 but
without water layer.

Is there any way to preserve water layer during Genbox peptide insertion?


James
-- 
gmx-users mailing listgmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Re: Fwd: [gmx-users] Npt equilibration of the membrane-mimicking CCl4 layer

2012-02-16 Thread James Starlight
Mark,

I'm using exact all parameters wich I found in different experimental work.

By the way reducing of integration step to 1fs provide me with better
equilibration of the Ccl4 system  ( I've being obtained stabile system
during 3 ns)

but I had a problems during ntp equilibration when I inserted test peptide
into that pre-equilibrated Ccl4 system and made two surrounded layer of
water. My system was quickly eqxanded on Z-dimension and slightly shrinked
on X.

I think that such problem could be due to some problems with the vdw radius
value for CCl4. E.g I didnt find this value in the vdwradii.dat file.


James

2012/2/16 Mark Abraham mark.abra...@anu.edu.au

  On 16/02/2012 1:45 AM, James Starlight wrote:

 Mark,

 I've used that dimensions in accordance to some literature where the same
 membrane-mimicking simulation were performed.

 I've tried to rise cutoffs


 Don't, that breaks your model physics and makes it even more likely you
 will encounter problems with the system dimensions becoming too small for
 the cut-off!


  and dicrease integration step but my system have been stil crashed during
 npt.

 I'm using
  pcoupl= Parrinello-Rahman

 wich I've found in the KALP tutorial because I have not found the same npt
 example file in the Biphastic tutorial :)


 So you're following some other work and not copying their equilibration
 protocol and/or model physics?


 Could you advise me another p_coup algorithm for my Ccl4 system?


 There's only two choices available. Manual 3.4.9 specifically warns
 against one of them for equilibration. What is there to say?

 You should be sure to construct a simple case and get the model physics
 validated. For the moment, forget about all the stuff where you were
 struggling to insert more CCl4 into a box with CCl4 (probably creating a
 far-from-equilibrium starting configuration). Don't try to learn to run on
 stilts while shaving. Learn to shave, then to walk on stilts, then to run,
 then start combining them.

 Mark



 James

 -- Forwarded message --
 From: Mark Abraham mark.abra...@anu.edu.au
 Date: 2012/2/15
 Subject: Re: [gmx-users] Npt equilibration of the membrane-mimicking CCl4
 layer
 To: Discussion list for GROMACS users gmx-users@gromacs.org


  On 15/02/2012 4:45 PM, James Starlight wrote:

 Mark,


 due to hight density the volume of my system have been slightly increased
 and during NPT phase I've obtained error

 Fatal error:
 One of the box vectors has become shorter than twice the cut-off length or
 box_yy-|box_zy| or box_zz has become smaller than the cut-off.

 I'm using 0.9 for electrostatic and 1.4 for vdw cutofs and the dimensions
 of my box was 6.5 3 3 on the initial step and 6.6 3 3.3 before crush :)

 I want prevent such expansion of my system by increasing of pressure and/
 or compressibility but I have not found exact sollution yet.


  Your system is dangerously small for those cut-offs if your initial
 density is not correct for your model physics. Your y and z dimensions only
 just contain a full cut-off sphere. You should also make sure you are
 following the advice about choice of P-coupling algorithm in manual 3.4.9,
 and consider using a very small integration time step. I remain unconvinced
 by this thread that you have generated a starting configuration that does
 not have atomic clashes.

 Mark




 James


 2012/2/14 Mark Abraham mark.abra...@anu.edu.au

  On 14/02/2012 11:01 PM, James Starlight wrote:

 This also was solved by the some extra minimisation steps.


 I've forced with another problem :D

 During npt equilibration my system have slightly expanded so my desired
 volume and density were perturbed.

 I've noticed the below options in npt wich could help me

 ref_p= 1 1
 compressibility = 4.5e-5

  i'm using this compressibility value   because I'm modelling the
 lipid-like environment so I think that I must increase pressure.  Could you
 remind me the dependence of pressure from density and volume for liquids ?
 :)


  Your forcefield, simulation cell contents and .mdp settings will
 determine the equilibrium density. Whether you need to do anything depends
 on whether you've made a statistically significant post-equilibration
 measurement of your average density. Haphazardly increasing the reference
 pressure for the coupling will reduce the volume, but now you are
 simulating at that pressure. See
 http://www.gromacs.org/Documentation/Terminology/Pressure for background
 info.

 Mark



 James



 2012/2/14 James Starlight jmsstarli...@gmail.com

 It seems that I've fixed that problem by reduce vdv radii for Cl during
 defining of my box

 Eventually I've obtained box with the desired density
  than I've delete vdvradii.dat for my wor dir

 by when I've launched equilibration I've oibtained

 Fatal error:
 Too many LINCS warnings (1598)
 If you know what you are doing you can adjust the lincs warning
 threshold in your mdp file

 I've never seen this before

 I'm using 1.o 

Re: Fwd: [gmx-users] Npt equilibration of the membrane-mimicking CCl4 layer

2012-02-16 Thread James Starlight
So my problem still is

1) During npt without peptide my Ccl4 system expan rapidly in X-dimension.
That produce error on 2nd ns of equilibration

One of the box vectors has become shorter than twice the cut-off length or
box_yy-|box_zy| or box_zz has become smaller than the cut-off.

2) During npt with peptide my system expan rapidly in Z direction ( along
that axe my peptide is oriented) So as concequence I've obtained the same
error.

Possible sollution wich I've found in litterature

1) To fix one dimension of my PB. How I could fix the X dimension of my box
during npt phace of pure Ccl4 and allow only change in 2 other dimensions ?

2) I have not found radius for Cl for Gromos56 ff.
Is this possible to decrease that value during npt phase to obtain system
with desired hight density? What value should I use?

James

2012/2/16 James Starlight jmsstarli...@gmail.com

 Mark,

 I'm using exact all parameters wich I found in different experimental work.

 By the way reducing of integration step to 1fs provide me with better
 equilibration of the Ccl4 system  ( I've being obtained stabile system
 during 3 ns)

 but I had a problems during ntp equilibration when I inserted test peptide
 into that pre-equilibrated Ccl4 system and made two surrounded layer of
 water. My system was quickly eqxanded on Z-dimension and slightly shrinked
 on X.

 I think that such problem could be due to some problems with the vdw
 radius value for CCl4. E.g I didnt find this value in the vdwradii.dat file.


 James


 2012/2/16 Mark Abraham mark.abra...@anu.edu.au

  On 16/02/2012 1:45 AM, James Starlight wrote:

 Mark,

 I've used that dimensions in accordance to some literature where the same
 membrane-mimicking simulation were performed.

 I've tried to rise cutoffs


 Don't, that breaks your model physics and makes it even more likely you
 will encounter problems with the system dimensions becoming too small for
 the cut-off!


  and dicrease integration step but my system have been stil crashed
 during npt.

 I'm using
  pcoupl= Parrinello-Rahman

 wich I've found in the KALP tutorial because I have not found the same
 npt example file in the Biphastic tutorial :)


 So you're following some other work and not copying their equilibration
 protocol and/or model physics?


 Could you advise me another p_coup algorithm for my Ccl4 system?


 There's only two choices available. Manual 3.4.9 specifically warns
 against one of them for equilibration. What is there to say?

 You should be sure to construct a simple case and get the model physics
 validated. For the moment, forget about all the stuff where you were
 struggling to insert more CCl4 into a box with CCl4 (probably creating a
 far-from-equilibrium starting configuration). Don't try to learn to run on
 stilts while shaving. Learn to shave, then to walk on stilts, then to run,
 then start combining them.

 Mark



 James

 -- Forwarded message --
 From: Mark Abraham mark.abra...@anu.edu.au
 Date: 2012/2/15
 Subject: Re: [gmx-users] Npt equilibration of the membrane-mimicking CCl4
 layer
 To: Discussion list for GROMACS users gmx-users@gromacs.org


  On 15/02/2012 4:45 PM, James Starlight wrote:

 Mark,


 due to hight density the volume of my system have been slightly increased
 and during NPT phase I've obtained error

 Fatal error:
 One of the box vectors has become shorter than twice the cut-off length
 or box_yy-|box_zy| or box_zz has become smaller than the cut-off.

 I'm using 0.9 for electrostatic and 1.4 for vdw cutofs and the dimensions
 of my box was 6.5 3 3 on the initial step and 6.6 3 3.3 before crush :)

 I want prevent such expansion of my system by increasing of pressure and/
 or compressibility but I have not found exact sollution yet.


  Your system is dangerously small for those cut-offs if your initial
 density is not correct for your model physics. Your y and z dimensions only
 just contain a full cut-off sphere. You should also make sure you are
 following the advice about choice of P-coupling algorithm in manual 3.4.9,
 and consider using a very small integration time step. I remain unconvinced
 by this thread that you have generated a starting configuration that does
 not have atomic clashes.

 Mark




 James


 2012/2/14 Mark Abraham mark.abra...@anu.edu.au

  On 14/02/2012 11:01 PM, James Starlight wrote:

 This also was solved by the some extra minimisation steps.


 I've forced with another problem :D

 During npt equilibration my system have slightly expanded so my desired
 volume and density were perturbed.

 I've noticed the below options in npt wich could help me

 ref_p= 1 1
 compressibility = 4.5e-5

  i'm using this compressibility value   because I'm modelling the
 lipid-like environment so I think that I must increase pressure.  Could you
 remind me the dependence of pressure from density and volume for liquids ?
 :)


  Your forcefield, simulation cell contents and .mdp settings will
 determine the 

Re: Fwd: [gmx-users] Npt equilibration of the membrane-mimicking CCl4 layer

2012-02-16 Thread Mark Abraham

On 17/02/2012 4:46 PM, James Starlight wrote:

So my problem still is

1) During npt without peptide my Ccl4 system expan rapidly in 
X-dimension. That produce error on 2nd ns of equilibration


One of the box vectors has become shorter than twice the cut-off 
length or box_yy-|box_zy| or box_zz has become smaller than the cut-off.


2) During npt with peptide my system expan rapidly in Z direction ( 
along that axe my peptide is oriented) So as concequence I've obtained 
the same error.


What does a cube of CCl4 do? If it is not stable at an acceptable 
density then your parameters don't work at all. Starting with simple 
things and adding complexity gradually is always a good policy, even 
when you're an expert. There's so many things that can be slightly wrong...




Possible sollution wich I've found in litterature

1) To fix one dimension of my PB. How I could fix the X dimension of 
my box during npt phace of pure Ccl4 and allow only change in 2 other 
dimensions ?


See pcoupltype in manual 7.3.15



2) I have not found radius for Cl for Gromos56 ff.
Is this possible to decrease that value during npt phase to obtain 
system with desired hight density? What value should I use?


As someone else said, the radius is only material during things like 
genbox. In the simulation, your nonbonded parameters are the important 
thing.


Mark
--
gmx-users mailing listgmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.

Can't post? Read http://www.gromacs.org/Support/Mailing_Lists


Re: Fwd: [gmx-users] Npt equilibration of the membrane-mimicking CCl4 layer

2012-02-16 Thread James Starlight
Mark,




The pure Ccl4 cube was expanded in X dimension during npt phase. By the way
I've been able to prevent it by increasing the ref_p of X up to 5 ussing
semiisotropic pcoupltype

By when I've inserted peptide on the npt of that system my Ccl4 box was
expanded on Z rapidly.

Might  this way to increase ref_p be usefull ?

I want to obtain very tightly packet Ccl4 layer with high density
(~1500kg/m^3) to mimick membrane acyl-chain hydrophobic layer

James
-- 
gmx-users mailing listgmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Re: Fwd: [gmx-users] Npt equilibration of the membrane-mimicking CCl4 layer

2012-02-16 Thread Mark Abraham

On 17/02/2012 5:33 PM, James Starlight wrote:

Mark,




The pure Ccl4 cube was expanded in X dimension during npt phase.


So assuming you simulated long enough to have reasonable convergence, 
your model is not stable at the initial volume with whatever that 
reference pressure was.


By the way I've been able to prevent it by increasing the ref_p of X 
up to 5 ussing semiisotropic pcoupltype


By when I've inserted peptide on the npt of that system my Ccl4 box 
was expanded on Z rapidly.


It's likely a waste of time to insert stuff into a solvent system that 
is far from equilibrium.




Might  this way to increase ref_p be usefull ?


Depends what you want to measure under what conditions.



I want to obtain very tightly packet Ccl4 layer with high density 
(~1500kg/m^3) to mimick membrane acyl-chain hydrophobic layer


So either you'll need high pressure or a different model of CCl4. Surely 
the work you are following addressed this. Your decision.


Mark
--
gmx-users mailing listgmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.

Can't post? Read http://www.gromacs.org/Support/Mailing_Lists


Re: Fwd: [gmx-users] Npt equilibration of the membrane-mimicking CCl4 layer

2012-02-15 Thread Mark Abraham

On 16/02/2012 1:45 AM, James Starlight wrote:

Mark,

I've used that dimensions in accordance to some literature where the 
same membrane-mimicking simulation were performed.


I've tried to rise cutoffs


Don't, that breaks your model physics and makes it even more likely you 
will encounter problems with the system dimensions becoming too small 
for the cut-off!


and dicrease integration step but my system have been stil crashed 
during npt.


I'm using
 pcoupl= Parrinello-Rahman

wich I've found in the KALP tutorial because I have not found the same 
npt example file in the Biphastic tutorial :)


So you're following some other work and not copying their equilibration 
protocol and/or model physics?



Could you advise me another p_coup algorithm for my Ccl4 system?


There's only two choices available. Manual 3.4.9 specifically warns 
against one of them for equilibration. What is there to say?


You should be sure to construct a simple case and get the model physics 
validated. For the moment, forget about all the stuff where you were 
struggling to insert more CCl4 into a box with CCl4 (probably creating a 
far-from-equilibrium starting configuration). Don't try to learn to run 
on stilts while shaving. Learn to shave, then to walk on stilts, then to 
run, then start combining them.


Mark



James

-- Forwarded message --
From: *Mark Abraham* mark.abra...@anu.edu.au 
mailto:mark.abra...@anu.edu.au

Date: 2012/2/15
Subject: Re: [gmx-users] Npt equilibration of the membrane-mimicking 
CCl4 layer
To: Discussion list for GROMACS users gmx-users@gromacs.org 
mailto:gmx-users@gromacs.org



On 15/02/2012 4:45 PM, James Starlight wrote:

Mark,


due to hight density the volume of my system have been slightly 
increased and during NPT phase I've obtained error


Fatal error:
One of the box vectors has become shorter than twice the cut-off 
length or box_yy-|box_zy| or box_zz has become smaller than the cut-off.


I'm using 0.9 for electrostatic and 1.4 for vdw cutofs and the 
dimensions of my box was 6.5 3 3 on the initial step and 6.6 3 3.3 
before crush :)


I want prevent such expansion of my system by increasing of pressure 
and/ or compressibility but I have not found exact sollution yet.


Your system is dangerously small for those cut-offs if your initial 
density is not correct for your model physics. Your y and z dimensions 
only just contain a full cut-off sphere. You should also make sure you 
are following the advice about choice of P-coupling algorithm in 
manual 3.4.9, and consider using a very small integration time step. I 
remain unconvinced by this thread that you have generated a starting 
configuration that does not have atomic clashes.


Mark





James


2012/2/14 Mark Abraham mark.abra...@anu.edu.au 
mailto:mark.abra...@anu.edu.au


On 14/02/2012 11:01 PM, James Starlight wrote:

This also was solved by the some extra minimisation steps.


I've forced with another problem :D

During npt equilibration my system have slightly expanded so my
desired volume and density were perturbed.

I've noticed the below options in npt wich could help me

ref_p= 1 1
compressibility = 4.5e-5

 i'm using this compressibility value   because I'm modelling
the lipid-like environment so I think that I must increase
pressure.  Could you remind me the dependence of pressure from
density and volume for liquids ? :)


Your forcefield, simulation cell contents and .mdp settings will
determine the equilibrium density. Whether you need to do
anything depends on whether you've made a statistically
significant post-equilibration measurement of your average
density. Haphazardly increasing the reference pressure for the
coupling will reduce the volume, but now you are simulating at
that pressure. See
http://www.gromacs.org/Documentation/Terminology/Pressure for
background info.

Mark




James



2012/2/14 James Starlight jmsstarli...@gmail.com
mailto:jmsstarli...@gmail.com

It seems that I've fixed that problem by reduce vdv radii
for Cl during defining of my box

Eventually I've obtained box with the desired density
 than I've delete vdvradii.dat for my wor dir

by when I've launched equilibration I've oibtained

Fatal error:
Too many LINCS warnings (1598)
If you know what you are doing you can adjust the lincs
warning threshold in your mdp file

I've never seen this before

I'm using 1.o cutoff for pme and 1.4 for vdv
my LINKS parameters are

; Bond parameters
continuation= no; first dynamics run
constraint_algorithm = lincs; holonomic constraints
constraints= all-bonds; all bonds (even heavy atom-H
bonds) constrained
lincs_iter= 1; accuracy of LINCS
lincs_order= 4; also related to