Re: [gmx-users] TOPOLOGY AND GRO FILE ATOMS NAME MISMATCH

2018-11-04 Thread Ali Ahmed
Hi
I believe gromacs uses atom names from topology if they are not matching.
Check atoms in PDB and compare them with topology then you will find what
is missing or the differences
Ali

On Sun, Nov 4, 2018 at 7:05 AM K. Subashini  wrote:

> Hi gromacs users,
>
> For an organic molecule,  the topology file was built using opls
> forcefield was obtained.
>
> Using gmx insert command, the gro file containing 150 molecules of the
> same organic compound placed in a box was obtained.
>
> Now the topology and gro file have non-matching atom names.
>
>
> How to fix the error?
>
> Thanks,
> Subashini.K
>
> --
> Gromacs Users mailing list
>
> * Please search the archive at
> http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before
> posting!
>
> * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists
>
> * For (un)subscribe requests visit
> https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or
> send a mail to gmx-users-requ...@gromacs.org.
>
-- 
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.


[gmx-users] Regarding xpm2ps with a xpm file obtained from gmx densmap [update] and possible bug

2018-11-04 Thread ABEL Stephane
Hi again, 

additional info about my issue with DensMap and xpm2ps

I noticed that  the number of decimals of the x/y axis values ​​in the xpm are 
smaller may have an effect of presence of the minor and major ticks in eps file 
obtained from xpm2ps (see below) Indeed with the same following params in the 
m2p 

x-major  = 1.0
x-minor  = 0.1
x-firstmajor = 0.0

y-major  = 1.0
y-minor  = 0.1
y-firstmajor = 0.0

and different examples

1) With PDB as input and 1 frame  I obtained the following xpm with the 
x-values (only a small part is shown) ---> minor and major ticlks are present 
in the eps
/* x-axis:  0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55 0.6 0.65 0.7 
0.75 0.8 0.85 0.9 0.95 1 1.05 1.1 1.15 1.2 1.25 1.3 1.35 1.4 1.45 1.5 1.55 1.6 
1.65 1.7 1.75 1.8 1.85 1.9 1.95 2 2.05 2.1 2.15 2.2 2.25 2.3 2.35 2.4 2.45 2.5 
2.55 2.6 2.65 2.7 2.75 2.8 2.85 2.9 2.95 3 3.05 3.1 3.15 3.2 3.25 3.3 3.35 3.4 
3.45 3.5 3.55 3.6 3.65 3.7 3.75 3.8 3.85 3.9 3.95 */

2) With PDB as input and 1000 frame I obtained the following xpm with the 
x-values (only a small part is shown) ---> minor and major ticlks are NOT 
present in the eps
/* x-axis:  0 0.0499876 0.0999751 0.149963 0.19995 0.249938 0.299925 0.349913 
0.399901 0.449888 0.499876 0.549863 0.599851 0.649838 0.699826 0.749814 
0.799801 0.849789 0.899776 0.949764 0.999751 1.04974 1.09973 1.14971 1.1997 
1.24969 1.29968 1.34966 1.39965 1.44964 1.49963 1.54961 1.5996 1.64959 1.69958 
1.74957 1.79955 1.84954 1.89953 1.94952 1.9995 2.04949 2.09948 2.14947 2.19945 
2.24944 2.29943 2.34942 2.3994 2.44939 2.49938 2.54937 2.59935 2.64934 2.69933 
2.74932 2.7993 2.84929 2.89928 2.94927 2.99925 3.04924 3.09923 3.14922 3.1992 
3.24919 3.29918 3.34917 3.39915 3.44914 3.49913 3.54912 3.59911 3.64909 3.69908 
3.74907 3.79906 3.84904 3.89903 3.94902 */

3) With XTC as input and 1 frame I obtained the following xpm with the x-values 
(only a small part is shown)  ---> minor and major ticlks are NOT present in 
the eps
/* x-axis:  0 0.054 0.11 0.150001 0.21 0.250002 0.32 0.350003 
0.43 0.450003 0.54 0.550004 0.64 0.650005 0.75 0.750005 
0.86 0.850006 0.97 0.950007 1.1 1.05001 1.10001 1.15001 1.20001 
1.25001 1.30001 1.35001 1.40001 1.45001 1.50001 1.55001 1.60001 1.65001 1.70001 
1.75001 1.80001 1.85001 1.90001 1.95001 2.1 2.05002 2.10002 2.15002 2.20002 
2.25002 2.30002 2.35002 2.40002 2.45002 2.50002 2.55002 2.60002 2.65002 2.70002 
2.75002 2.80002 2.85002 2.90002 2.95002 3.2 3.05002 3.10002 3.15002 3.20002 
3.25002 3.30002 3.35002 3.40002 3.45003 3.50003 3.55003 3.60003 3.65003 3.70003 
3.75003 3.80003 3.85003 3.90003 3.95003 */

and 4)  With XTC as input and 1000 frames I obtained the following xpm with the 
x-values (only a small part is shown)  ---> minor and major ticlks are NOT 
present in the eps
/* x-axis:  0 0.0499876 0.0999751 0.149963 0.19995 0.249938 0.299925 0.349913 
0.399901 0.449888 0.499876 0.549863 0.599851 0.649838 0.699826 0.749814 
0.799801 0.849789 0.899776 0.949764 0.999751 1.04974 1.09973 1.14971 1.1997 
1.24969 1.29968 1.34966 1.39965 1.44964 1.49963 1.54961 1.5996 1.64959 1.69958 
1.74956 1.79955 1.84954 1.89953 1.94952 1.9995 2.04949 2.09948 2.14947 2.19945 
2.24944 2.29943 2.34942 2.3994 2.44939 2.49938 2.54937 2.59935 2.64934 2.69933 
2.74932 2.7993 2.84929 2.89928 2.94927 2.99925 3.04924 3.09923 3.14922 3.1992 
3.24919 3.29918 3.34917 3.39915 3.44914 3.49913 3.54912 3.5991 3.64909 3.69908 
3.74907 3.79906 3.84904 3.89903 3.94902 */


I used for the above examples the same densmap and xpm2ps commands show below 
and the 5.1.4 and 2018.2 gromacs version. It is a bug related to the rounding 
in the xpm2ps or I miss something ?

Thank you in advance for your help

Stéphane


--

Message: 4
Date: Sat, 3 Nov 2018 17:45:53 +
From: ABEL Stephane 
To: "gromacs.org_gmx-users@maillist.sys.kth.se"

Subject: [gmx-users] Regarding xpm2ps with a xpm file obtained from
gmx densmap
Message-ID:
<3e39b768bb199548ab18f7289e7534af4887a...@exdag0-b0.intra.cea.fr>
Content-Type: text/plain; charset="iso-8859-2"

Thanks you Justin for your help but I still have the smae problem . I have 
changed in my m2p file the floowing fields

x-major  = 1.0; Major ticks on x axis every .. 
frames
x-minor  = 0.05 ; Id. Minor ticks
x-firstmajor = 0.0  ; First frame for major tick

y-major  = 1.0  ; Major ticks on y axis every .. frames
y-minor  = 0.05 ; Id. Minor ticks
y-firstmajor = 0.0

and use the xpm, some (not all) sticks  appeared in each axis but w/o the 
labels. I still do not understand why ...

St?phane


--

On 11/3/18 12:19 PM, ABEL Stephane wrote:
> Hello,
>
> I am using the below .m2p file as input for

[gmx-users] TOPOLOGY AND GRO FILE ATOMS NAME MISMATCH

2018-11-04 Thread K. Subashini
Hi gromacs users,

For an organic molecule,  the topology file was built using opls forcefield was 
obtained.

Using gmx insert command, the gro file containing 150 molecules of the same 
organic compound placed in a box was obtained.

Now the topology and gro file have non-matching atom names.


How to fix the error?

Thanks,
Subashini.K

-- 
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 