[Histonet] Bone labelling for Microdamage

2009-12-01 Thread Karie Reaser
Is it ok to process cortical bone, embed in MMA, section and grind on the Exakt 
system. Last do the bone labelling stain? Or do I have to do the bone labelling 
stain prior to embedding, sectioning and mounting on slides? Any suggestions 
would be greatly appreciated.

-- 
Karie L Reaser A.S.
New Bolton Center
University of Pennsylvania
School of Veterinary Medicine
Comparative Orthopedic Research Laboratory
382 W Street Road
Kennett Square, PA. 19348
Phone:610-925-6278
Fax:610-925-8120
Email:krea...@vet.upenn.edu


___
Histonet mailing list
Histonet@lists.utsouthwestern.edu
http://lists.utsouthwestern.edu/mailman/listinfo/histonet


Re: [Histonet] Bone labelling for Microdamage

2009-12-01 Thread Jack Ratliff

Karie,

If you are looking for microdamage or are using basic fuchsin, I have  
been taught to bulk stain with 1% basic fuchsin in your processing  
solutions (i.e. 1% BF in 70% EtOH, 1% BF in 80% EtOH, 1% BF in 95%  
EtOH, and 1% BF in 100% EtOH) and then finish as you would with the  
remaining steps for your MMA protocol (i.e. xylenes, MMA +DBP, etc.)  
to achieve a fully polymerized bulk stained specimen. You then cut,  
grind, and polish as required for use with the EXAKT system. I was  
told the reason you process with the BF is because the cutting and  
grinding causes additional microdamage and if you stain first the  
additional damage will not be stained.


If you are talking about labeling bone for calculations of BFR or MAR  
and the animal did not receive timed injections of calcein, alizarin,  
tetracycline, or some other fluorescent bone label before necropsy,  
then you could try doing a 0.6% FA etch for 30 seconds followed with  
Sanderson's Rapid Bone Stain for 3 minutes, brief tap water rinse, and  
blot dry.


What is the exact specimen you are working with and what do you  
specifically wish to demonstrate


Jack



On Dec 1, 2009, at 10:04 AM, Karie Reaser krea...@vet.upenn.edu wrote:

Is it ok to process cortical bone, embed in MMA, section and grind  
on the Exakt system. Last do the bone labelling stain? Or do I have  
to do the bone labelling stain prior to embedding, sectioning and  
mounting on slides? Any suggestions would be greatly appreciated.


--
Karie L Reaser A.S.
New Bolton Center
University of Pennsylvania
School of Veterinary Medicine
Comparative Orthopedic Research Laboratory
382 W Street Road
Kennett Square, PA. 19348
Phone:610-925-6278
Fax:610-925-8120
Email:krea...@vet.upenn.edu


___
Histonet mailing list
Histonet@lists.utsouthwestern.edu
http://lists.utsouthwestern.edu/mailman/listinfo/histonet



___
Histonet mailing list
Histonet@lists.utsouthwestern.edu
http://lists.utsouthwestern.edu/mailman/listinfo/histonet