Re: HSM filing up 3592 cartridges
On Tue, 3 Mar 2009 07:13:26 +0200, Arye Shemer ary...@matrix.co.il wrote: Customer is using HSM and claims that HSM won't let him put more then 99 disk volume backups on one cartridge. Is there is a way to overcome this limit? The customer would like to utilize his 3592 cartridges more efficiently. When we bought jaguars we realised the HSM STACK parameter could not exceed 99 and of course we could not fill our cartridge we made a request but i do not know what happened to it In between we moved from mod3 to bigger models ( mod9 and 27) and bypassed the problem at the same time . I do not think the 99 limit was changed. Bruno Sugliani zxnetconsult(at)free(dot)fr http://zxnetconsult.free.fr -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: HSM filing up 3592 cartridges
Arye Shemer wrote: We suggested to the customer to switch to larger volumes, but he said: They are small software developing shop and need small volumes for the developers' teams. I agree the limit of 99 could be inconvenient. However, the limit exist and you have a choice: increase volume size or live with partially-full cartridges. BTW: I strongly believe they DON'T need small volumes. Probably they need SMS and some naming convention. Separation at volume level is not needed. My €0.02 -- Radoslaw Skorupka Lodz, Poland -- BRE Bank SA ul. Senatorska 18 00-950 Warszawa www.brebank.pl Sd Rejonowy dla m. st. Warszawy XII Wydzia Gospodarczy Krajowego Rejestru Sdowego, nr rejestru przedsibiorców KRS 025237 NIP: 526-021-50-88 Wedug stanu na dzie 01.01.2009 r. kapita zakadowy BRE Banku SA (w caoci wpacony) wynosi 118.763.528 zotych. W zwizku z realizacj warunkowego podwyszenia kapitau zakadowego, na podstawie uchway XXI WZ z dnia 16 marca 2008r., oraz uchway XVI NWZ z dnia 27 padziernika 2008r., moe ulec podwyszeniu do kwoty 123.763.528 z. Akcje w podwyszonym kapitale zakadowym BRE Banku SA bd w caoci opacone. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: HSM filing up 3592 cartridges
I don't remember if this was answered or not, but is there really a 99 volume limit in DFHSM? I would think that would be something fairly easy for the HSM people to change, atlhough I may be wrong about that. This whole thread reminds me of one of my first big projects as a sysprog when I worked for Milwaukee County. I wrote a system like HSM for backing up the changed and new datasets on our TSO packs. Everything back then was backed up to tape (good old 3420 round reels - state of the art at the time). I wrote everything out to tape using IEBGENER for one set of tapes, and IEBCOPY for another set of tapes. I think back then, the LABEL= parameter had a limit of 99, so we put a maximum of 99 files on each tape. Ah for the good old days when I wrote a lot of assembler! Eric Bielefeld Sr. Systems Programmer Milwaukee, Wisconsin 414-475-7434 - Original Message - From: Arye Shemer ary...@matrix.co.il Newsgroups: bit.listserv.ibm-main To: IBM-MAIN@bama.ua.edu Sent: Wednesday, March 04, 2009 1:15 AM Subject: Re: HSM filing up 3592 cartridges We suggested to the customer to switch to larger volumes, but he said: They are small software developing shop and need small volumes for the developers' teams. -Original Message- From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On Behalf Of Scott Rowe Sent: Tuesday, March 03, 2009 10:20 PM To: IBM-MAIN@bama.ua.edu Subject: Re: HSM filing up 3592 cartridges Use bigger volumes? Arye Shemer ary...@matrix.co.il 3/3/2009 12:13 AM Hello, Customer is using HSM and claims that HSM won't let him put more then 99 disk volume backups on one cartridge. Is there is a way to overcome this limit? The customer would like to utilize his 3592 cartridges more efficiently. Thanks, Arye Shemer. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: HSM filing up 3592 cartridges
I'm sorry - this was answered quite definitively a few posts after the one that I responded to. I violated my rule of reading the rest of the posts on a topic before responding, and especially before asking questions! Eric Eric Bielefeld Sr. Systems Programmer Milwaukee, Wisconsin 414-475-7434 - Original Message - From: Eric Bielefeld eric-ibmm...@wi.rr.com I don't remember if this was answered or not, but is there really a 99 volume limit in DFHSM? I would think that would be something fairly easy for the HSM people to change, atlhough I may be wrong about that. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: HSM filing up 3592 cartridges
Not at this time snip Customer is using HSM and claims that HSM won't let him put more then 99 disk volume backups on one cartridge. Is there is a way to overcome this limit? /snip -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: HSM filing up 3592 cartridges
Are you referring to data set backups or full volume dumps? -Original Message- From: Arye Shemer Sent: Monday, March 02, 2009 9:13 PM To: IBM-MAIN@bama.ua.edu Subject: HSM filing up 3592 cartridges Hello, Customer is using HSM and claims that HSM won't let him put more then 99 disk volume backups on one cartridge. Is there is a way to overcome this limit? The customer would like to utilize his 3592 cartridges more efficiently. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: HSM filing up 3592 cartridges
Use bigger volumes? Arye Shemer ary...@matrix.co.il 3/3/2009 12:13 AM Hello, Customer is using HSM and claims that HSM won't let him put more then 99 disk volume backups on one cartridge. Is there is a way to overcome this limit? The customer would like to utilize his 3592 cartridges more efficiently. Thanks, Arye Shemer. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html CONFIDENTIALITY/EMAIL NOTICE: The material in this transmission contains confidential and privileged information intended only for the addressee. If you are not the intended recipient, please be advised that you have received this material in error and that any forwarding, copying, printing, distribution, use or disclosure of the material is strictly prohibited. If you have received this material in error, please (i) do not read it, (ii) reply to the sender that you received the message in error, and (iii) erase or destroy the material. Emails are not secure and can be intercepted, amended, lost or destroyed, or contain viruses. You are deemed to have accepted these risks if you communicate with us by email. Thank you. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: HSM filing up 3592 cartridges
I agree, if you use larger volumes, you won't find the 99 volume count an issue. Brian -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: HSM filing up 3592 cartridges
Question: Are you referring to data set backups or full volume dumps? Question Answer: The customer is doing full volume dumps -Original Message- From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On Behalf Of Schwarz, Barry A Sent: Tuesday, March 03, 2009 10:10 PM To: IBM-MAIN@bama.ua.edu Subject: Re: HSM filing up 3592 cartridges Are you referring to data set backups or full volume dumps? -Original Message- From: Arye Shemer Sent: Monday, March 02, 2009 9:13 PM To: IBM-MAIN@bama.ua.edu Subject: HSM filing up 3592 cartridges Hello, Customer is using HSM and claims that HSM won't let him put more then 99 disk volume backups on one cartridge. Is there is a way to overcome this limit? The customer would like to utilize his 3592 cartridges more efficiently. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html This mail was received via Mail-SeCure System. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: HSM filing up 3592 cartridges
We suggested to the customer to switch to larger volumes, but he said: They are small software developing shop and need small volumes for the developers' teams. -Original Message- From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On Behalf Of Scott Rowe Sent: Tuesday, March 03, 2009 10:20 PM To: IBM-MAIN@bama.ua.edu Subject: Re: HSM filing up 3592 cartridges Use bigger volumes? Arye Shemer ary...@matrix.co.il 3/3/2009 12:13 AM Hello, Customer is using HSM and claims that HSM won't let him put more then 99 disk volume backups on one cartridge. Is there is a way to overcome this limit? The customer would like to utilize his 3592 cartridges more efficiently. Thanks, Arye Shemer. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html CONFIDENTIALITY/EMAIL NOTICE: The material in this transmission contains confidential and privileged information intended only for the addressee. If you are not the intended recipient, please be advised that you have received this material in error and that any forwarding, copying, printing, distribution, use or disclosure of the material is strictly prohibited. If you have received this material in error, please (i) do not read it, (ii) reply to the sender that you received the message in error, and (iii) erase or destroy the material. Emails are not secure and can be intercepted, amended, lost or destroyed, or contain viruses. You are deemed to have accepted these risks if you communicate with us by email. Thank you. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html This mail was received via Mail-SeCure System. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
HSM filing up 3592 cartridges
Hello, Customer is using HSM and claims that HSM won't let him put more then 99 disk volume backups on one cartridge. Is there is a way to overcome this limit? The customer would like to utilize his 3592 cartridges more efficiently. Thanks, Arye Shemer. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html