Re: time used on Ready; prompt

2011-08-10 Thread Jeffrey Forte
It is still there ... Try SET RDYMSG LMSG


--  Jeff Forte
  IBM Global Services
  z/VM System Support
  E-mail: jfo...@us.ibm.com
 --  Phone:720-396-1716 (TL 938-1716) 



From:   Gentry, Steve steve.gen...@westernsouthernlife.com
To: IBMVM@LISTSERV.UARK.EDU
Date:   08/10/2011 11:14 AM
Subject:time used on Ready;  prompt
Sent by:The IBM z/VM Operating System IBMVM@LISTSERV.UARK.EDU



Does anyone remember when or what release IBM stopped displaying the
time used(for lack of the correct term) on the Ready; prompt?  I was
talking to an old IBM'er/VM'er and he asked about it.  I had forgotten
that it used to be displayed.  Just curious when it disappeared.
Thanks,
Steve



Re: z/VM RACF AUDIT RECORD

2010-03-17 Thread Jeffrey Forte
Take a look at the SMF CONTROL on the RACFVM 191.


Jeff Forte



   
  From:   Kris Buelens kris.buel...@gmail.com 
   

   
  To: IBMVM@LISTSERV.UARK.EDU   
   

   
  Date:   03/17/2010 03:37 AM   
   

   
  Subject:Re: z/VM RACF AUDIT RECORD
   

   
  Sent by:The IBM z/VM Operating System IBMVM@LISTSERV.UARK.EDU   
   

   





I don't think it can be changed, and,it is only 4 characters, revealing the
fact that RACFVM was ported from MVS where some kind of system ID was
limited to 4 characters.

2010/3/16 Martin, Terry R. (CMS/CTR) (CTR) terry.mar...@cms.hhs.gov



  Hi





  I am collecting z/VM RACF Audit records from SMF and I see a SYSID of
  ‘VMSP’. I would like to change this to match the LPAR name can this be
  changed and if so where is found?





  User Date    Time Jobname
  Description
  Sys


  DATAMOVE 14 Mar 2010 05:29:45.56   RACF RACINIT success for
  DATAMOVE: Job Start / Logon   VMSP








  Thank You,





  Terry Martin


  Lockheed Martin - Citic:


  z/OS and z/VM Performance Tuning and Operating Systems Support


  Office - 443 348-2102


  Cell - 443 632-4191














--
Kris Buelens,
IBM Belgium, VM customer support






Re: Ethernet vswitch definition

2009-01-08 Thread Jeffrey Forte
Check the PSP bucket for 5.4 RSU0801 ... I saw it in there yesterday.


--  Jeff Forte
  IBM Global Services
  z/VM System Support
  E-mail: jfo...@us.ibm.com
 --  Phone:877-548-1651 (TL 349-8649)


   
 Bauer, Bobby 
 (NIH/CIT) [E]
 baue...@mail.nih  To 
 .gov IBMVM@LISTSERV.UARK.EDU 
 Sent by: The IBM   cc 
 z/VM Operating
 SystemSubject 
 ib...@listserv.u Re: Ethernet vswitch definition 
 ARK.EDU  
   
   
 01/08/2009 01:57  
 PM
   
   
 Please respond to 
   The IBM z/VM
 Operating System  
 ib...@listserv.u 
 ARK.EDU  
   
   




Thanks, that fixed the syntax error. Who would have though IBM could make
that mistake?

Did an IBMLINK search but so far haven’t found any PTF that looked like
this.


Bobby Bauer
Center for Information Technology
National Institutes of Health
Bethesda, MD 20892-5628
301-594-7474

From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On
Behalf Of Bob Bates
Sent: Thursday, January 08, 2009 1:52 PM
To: IBMVM@LISTSERV.UARK.EDU
Subject: Re: Ethernet vswitch definition

We had this same problem. There is actually nothing wrong with the line but
the checker looks at the length of the parms following RDEV until one is
greater than 4 characters (if I remember right). Try repositioning the VLAN
4000 after TRUNK. There is a fix out there for it.



Bob Bates
Enterprise Hosting Services

w. (469)892-6660
c. (214) 907-5071


“This message may contain confidential and/or privileged information.  If
you are not the addressee or authorized to receive this for the addressee,
you must not use, copy, disclose, or take any action based on this message
or any information herein.  If you have received this message in error,
please advise the sender immediately by reply e-mail and delete this
message.  Thank you for your cooperation.




From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On
Behalf Of Bauer, Bobby (NIH/CIT) [E]
Sent: Thursday, January 08, 2009 12:33 PM
To: IBMVM@LISTSERV.UARK.EDU
Subject: Ethernet vswitch definition

We are looking at converting our vswitch from IP to Ethernet. As my first
step I’m trying to get the syntax correct in SYSTEM CONFIG

I comment out my current vswitch define and add the new one

/*Define vswitch zvm1 rdev 0c60 0c70 */
Define vswitch zvm1 rdev 0c60 0c70 VLAN 4000  PORTT TRUNK  ETH

When I syntax check it I get an error

  2853 +++dVal = x2d(xVal)
  1906 +++   if ( xInRange(tok,loRange,hiRange) = 0 )
  1206 +++ call handle_token
   278 +++  call verify_statement/* Verify statement syntax */
DMSREX475E Error 40 running CPSYNTAX EXEC, line 2853: Incorrect call to
routine

which isn’t exactly helpful. It didn’t even tell me what line the error was
on. z/VM 5.4  Anybody see my error?


Bobby Bauer
Center for Information Technology
National Institutes of Health
Bethesda, MD 20892-5628
301-594-7474






Re: Switching between Xedit screens.

2008-11-21 Thread Jeffrey Forte

X on the command line will flip through the xedit ring.


 I first Xedit one file then Xedit a second file, now there is one up
front and one in the background.

 I don't want to do a 'screen 2' because it's to small, not enough text
showing.

 How do I flip between the two screens?  There has to be an easy way to
do this.

 Thanks.