[Ifeffit] Trouble with Artemis

2011-08-03 Thread Morgan Scott
Hello;

Trying to plot a fit in Artemis.
My .dat files appear flat on y= zero in the plot window.
they open fine in Athena.
Any help would be appreciated.

regards
___
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit


Re: [Ifeffit] Trouble with Artemis

2011-08-03 Thread Dr. Dariusz A. ZajÄ…c

plots parameters, options are the same for Artemis and Athena?
regards

W dniu 11-08-03 08:23, Morgan Scott pisze:

Hello;

Trying to plot a fit in Artemis.
My .dat files appear flat on y= zero in the plot window.
they open fine in Athena.
Any help would be appreciated.

regards




___
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit


___
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit


[Ifeffit] Invitation to connect on LinkedIn

2011-08-03 Thread Somaditya Sen
LinkedIn




   
ifeffit,

I'd like to add you to my professional network on LinkedIn.

- Somaditya

Somaditya Sen
Research Associate at Physics Dept., UWM 
Greater Milwaukee Area

Confirm that you know Somaditya Sen
https://www.linkedin.com/e/o6ijfu-gqwaay89-k/isd/3744123338/3Yn0HeKq/


 
-- 
(c) 2011, LinkedIn Corporation___
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit


[Ifeffit] Athena: problems with LCF

2011-08-03 Thread Nina Siebers

Dear All,

I acquired Cd L3-edge spectra of some binary and ternary mixtures in  
varying proportions and for the individual components. Then, I tried  
to fit the reference spectra to the spectra of the mixtures using  
linear combination fitting of Athena to get their abundance. However,  
results were disappointing despite all spectra were carefully energy  
calibrated and normalized, so I decided to create simple mathematical  
ternary mixtures by summing up the spectra of the individual reference  
spectra (edge step normalized) and tried the fitting again to exclude  
mixing-failures and check sensitivity of LCF with the idealized  
spectra. Unfortunately, LCF was also not able to reliable deconvolute  
these spectra into the individual reference spectra.

Does anybody have an explanation for that?
It would be nice if somebody could give me information about the  
mathematical fitting algorithm implemented in Athena.


Thanks a lot!
Wishes,
Nina
___
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit


Re: [Ifeffit] Fe K-edge second shell problems

2011-08-03 Thread Andrea L Foster
Paul, have you considered explicitly multiple scattering from within the 
tetrahedron?  The short distance you describe for the second shell might 
be consistent with that.

Its pretty easy to write an expression in the fit routine that makes the 
MS path distances explicitly dependent on the SS paths (no new variables 
in the fit)--the number of MS paths is constrained by the geometry 
(tetrahedral).  The order of scattering is probably just 3- and 4- legged 
MS paths, no higher (would give longer distances)

I study arsenic, and so I've seen this approach described in the following 
paper on As: 

Voegelin et al (2007) Geochimica et Cosmochimica Acta v. 71, pp. 
5804-5820.  Look in the section 2.6 for the details.

sorry if someone already answered this,


~~
Andrea L. Foster, Ph.D.
U.S.G.S. WMESC
345 Middlfield Rd., MS 901
Menlo Park, CA 94025
T: 650-329-5437
F: 650-329-5491

___
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit


Re: [Ifeffit] Fe K-edge second shell problems

2011-08-03 Thread Scott Calvin

Hi Paul,

Looking at your data, I agree that there does seem to be second-shell  
scattering present in the signal.


Unfortunately, that most likely means that your material is not close  
to one of the obvious model compounds. One possibility to keep in  
mind is that you may have some kind of overlapping paths in that  
second shell--for example, partially Fe-Na and partially Fe-Ca, or  
an assortment of Fe-Na's at different distances.


A clue can perhaps be obtained by noting the relative height of the  
peak near 2.3 angstroms compared with the large peak you've fit. As k- 
weight is raised from  0 to 1 to 2 to 3, the peak at 2.3 angstroms  
does not grow relative to the first peak. That suggests the scattering  
may be from another low-Z element like oxygen.


So I'd tentatively try an Fe-O path around 2.7 angstroms with its own  
delR, ss, and N guessed. (Meanwhile, set N_1 to 4 to reduce  
correlations--you've said you expect the first shell to be tetrahedral.)


Good luck--sounds like a stubborn one!

--Scott Calvin
Sarah Lawrence College

On Aug 3, 2011, at 9:49 AM, Paul A Bingham wrote:


Dear Ifeffit users,

I have been struggling with this problem on and off for many months
and I cannot resolve it - hopefully someone out there can help

I have collected fluorescence Fe K-edge EXAFS of oxide glasses doped
with low levels (0.2%) of Fe. The glasses are typified by their major
components SiO2, Na2O, CaO and also low levels of Fe2O3 and CeO2
dopants. I'm currently trying to fit the Fe EXAFS. The first shell is
relatively easy to fit and I'm reasonably happy with the fit I
obtained using a tetrahedral Fe3+ standard, in this case FePO4. The
fits are consistent, as I expected to find, with Fe3+
tetrahedrally-coordinated with four oxygens.

The problem comes - and here's where I could really use some
suggestions - when I try to fit second Fe-x distance. It seems clear
to me that a second Fe-x distance (and possibly a third) are present
in the data. However, despite expending a great deal of time I am
unable to get a fit that appears anywhere near sensible and robust and
for which the output parameters are sensible. I suspect the second
Fe-x distance (I reckon about 2.8 Angstroms) to be Fe-Na but Fe-Ca,
Fe-Si or Fe-O may also be possible. It's also possible that it is
Fe-Fe or Fe-Ce.

I have tried all of the obvious Fe model compounds (aegirine,
clinopyroxine, etc) and also many others and I simply cannot get
anything approaching a decent fit. The vast majority of distances in
model compounds are Fe-O distances around 1.9-2.1A, then there is
usually a gap until about 3.1A.

I have checked my background subtraction and tried out many different
options, changes and tweaks that I know or can find suggested but I
cannot obtain a fit that is any good. And so I ask my colleagues out
there who are more experienced than I with EXAFS - can anyone help
with this conundrum?

I have attached the Artemis file with the data and simple one-shell
fit using FePO4 cif file; and the Athena file FYI.

Thanks in advance for your time and I look forward very much to
reading any suggestions you may have.

Warm Regards

Paul Bingham

--
Dr. Paul A. Bingham
Immobilisation Science Laboratory
Dept. of Engineering Materials
University of Sheffield
Mappin Street
Sheffield
S1 3JD
UK

Email: p.a.bing...@sheffield.ac.uk
Direct Line: (0114) 2225473
 
Bingham_Fe_EXAFS_Glass_Ifeffit_Artemis 
Bingham_Fe_EXAFS_Glass_Ifeffit_Athena.prjATT1..txt


___
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit


[Ifeffit] Postdoctoral position at Yeshiva University

2011-08-03 Thread Frenkel, Anatoly
Dear IFEFFIT subscribers: 
Please find here the info about the job opening:

Postdoctoral position at Yeshiva University

Physics Department of Yeshiva University in New York City has immediate opening 
for a postdoctoral research associate position. The postdoc will investigate 
thermal, structural and electronic properties of nanocatalysts and contribute 
to the ongoing research in heterogeneous catalysis. He or she will be stationed 
at Brookhaven National Laboratory (BNL) and work closely with BNL departments 
(NSLS, Chemistry, Physics/Materials Science and the CFN) as well as the outside 
collaborators. Required qualifications: expert knowledge of XAFS and x-ray 
diffraction and experience with nanomaterials characterization. Hands on 
experience with vibrational spectroscopies (Raman, IR) and electron microscopy 
is a plus. The research will be performed under the direction of Prof. Anatoly 
Frenkel primarily at the Synchrotron Catalysis Consortium 
(http://www.yu.edu/scc 
https://webmail.bnl.gov/exchange/frenkel/Drafts/RE:%20[Ifeffit]%20Fe%20K-edge%20second%20shell%20problems.EML/redir.aspx?C=44fc2d9c1c7d43be96daee679b109becURL=http%3a%2f%2fwww.yu.edu%2fscc
 ) at the National Synchrotron Light Source. Applicants should forward cover 
letter and CV, and arrange for three letters of recommendation to be sent to 
Prof. Frenkel at anatoly.fren...@yu.edu. Yeshiva University is an Equal 
Opportunity Employer. 


Anatoly Frenkel, Ph.D., Professor
Department of Physics, Yeshiva University
245 Lexington Avenue, New York, NY 10016
http://www.yu.edu/faculty/afrenkel 
https://webmail.bnl.gov/exchange/frenkel/Drafts/RE:%20[Ifeffit]%20Fe%20K-edge%20second%20shell%20problems.EML/redir.aspx?C=44fc2d9c1c7d43be96daee679b109becURL=http%3a%2f%2fwww.yu.edu%2ffaculty%2fafrenkel
 

Spokesperson, Synchrotron Catalysis Consortium
http://www.yu.edu/scc 
https://webmail.bnl.gov/exchange/frenkel/Drafts/RE:%20[Ifeffit]%20Fe%20K-edge%20second%20shell%20problems.EML/redir.aspx?C=44fc2d9c1c7d43be96daee679b109becURL=http%3a%2f%2fwww.yu.edu%2fscc
 

Office: (212) 340-7827, Lab: (631) 344-3013, Email: anatoly.fren...@yu.edu
 
 
winmail.dat___
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit