Re: [Ifeffit] Linear Combination Fitting using ATHENA

2013-08-12 Thread Alexandre dos Santos Anastacio
Hello,

maybe that fingerprinting technique would be Mossbauer spectroscopy. The
Fe(II)/Fe(III) ratio comes easily and also there are lots of papers about
Mg-ferrite, an example:

10.1109/TMAG.2009.2018880 http://dx.doi.org/10.1109/TMAG.2009.2018880

Alexandre.
___
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit


Re: [Ifeffit] Linear Combination Fitting using ATHENA

2013-08-12 Thread Latta, Drew E.
I would say that the Mossbauer isn't always quite straight forward, especially 
if the OP is working with nanoparticles. You have to find the right temperature 
where superparamagnetism is gone but the Verwey transition hasn't occurred to 
reliably fit the resulting Mossbauer spectra. (I'll assume from ignorance that 
that Mg-ferrites have Verwey transitions.)

I would think the two best end-members for the XAS LC fits are possibly 
magnetite (fully stoichiometric: Fe2+/Fe3+ = 0.5) and either maghemite 
(gamma-Fe2O3) or the fully oxidized Mg-ferrite. Which Fe2O3 are you using Teck 
Kwang Choo? If you are using the alpha-form (hematite) then I would suspect you 
might not get very good fits as the structural difference between maghemite and 
hematite significantly influence their XANES spectra.

I've had good success finding Fe2+/Fe3+ ratios in partially oxidized magnetites 
by using magnetite and maghemite as end-members in LC fits. So I think you 
should have reasonable success for the Mg-ferrites using the right end-members.

Contact me in person below, if you are interested in magnetite/maghemite 
standard spectra.

Best,

Drew Latta
---
Drew E. Latta, Ph.D.
Postdoctoral Associate

Molecular Environmental Science Group
Biosciences Division
Argonne National Laboratory
Building 203, Room E-105
9700 South Cass Avenue
Argonne, IL  60439

Phone: 1-630-252-3985
dla...@anl.govmailto:dla...@anl.gov
http://www.mesg.anl.gov
---



From: ifeffit-boun...@millenia.cars.aps.anl.gov 
[mailto:ifeffit-boun...@millenia.cars.aps.anl.gov] On Behalf Of Alexandre dos 
Santos Anastacio
Sent: Monday, August 12, 2013 9:01 AM
To: XAFS Analysis using Ifeffit
Subject: Re: [Ifeffit] Linear Combination Fitting using ATHENA

Hello,

maybe that fingerprinting technique would be Mossbauer spectroscopy. The 
Fe(II)/Fe(III) ratio comes easily and also there are lots of papers about 
Mg-ferrite, an example:

10.1109/TMAG.2009.2018880http://dx.doi.org/10.1109/TMAG.2009.2018880

Alexandre.

___
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit


[Ifeffit] issues with Athena (new Demeter package)

2013-08-12 Thread Adrian Gainar
Hi All,

I experience two issues with Athena of the updated new Demeter package, which 
it would be easier to describe:

1) when I open successively two .prj files that contain each a fitted spectrum, 
Athena seems to remember only the positions, widths and amplitudes of arctan 
and gaussian curves  of the spectrum I open first; this translates to the fact 
that for the other fitted spectra that I open afterwards, it remembers the peak 
positions, widths and amplitudes of the curves belonging to the initially 
opened spectrum. The result of this issue is that I need to enter manually each 
time these values in order to get the fits back again - do you have any 
suggestions how this can be fixed?;
2) another issue is that after spectra calibrations, the spectrum does not 
appear to be calibrated. More specifically, when one checks the centroid 
positions of arctan or gaussian curves directly on the spectrum, the values 
don't correspond with the ones in the boxes, which I believe that means the 
calibration did not happen after all.

Thank you very much in advance for any suggestions or ideas!

Best wishes,
Adrian


***
Adrian Gainar

PhD student
Office: D37
School of Chemical Engineering and Analytical Science
Jackson's Mill

University of Manchester
Manchester
M13 9PL
UK

e-mail address contact: 
adrian.gai...@postgrad.manchester.ac.ukmailto:adrian.gai...@postgrad.manchester.ac.uk
office telephone no.: +44(0)161 306 4362





___
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit


Re: [Ifeffit] Recommendations for DFT/computational chemistry software?

2013-08-12 Thread Ryan Nelson
Hi Scott,

Gaussian is a pretty solid program. The input files are easy to write, and
it's popularity make it easy to find support. It is a commercial product,
though, which can be a problem if your on a tight budget.

Several years back, I tried Gamess, which worked fine. Its biggest drawback
for me was writing input files. It was cumbersome to use mixed/custom basis
sets, which is probably key for anything you'll be doing for EXAFS. I
haven't tried Gamess recently, so the situation may have changed.

I hear good things about Orca as well. I think this package does a lot of
interesting stuff related to XAS, but I haven't spent much time with it. A
couple years back, Orca couldn't do analytical frequency calculations,
which, in my experience, led to very slow frequency calculations. However,
according to the website, it seems like that feature will be coming soon,
so I would like to find some time to really play around with this program
again.

My colleague uses WebMO, which is a web-based frontend to many electronic
structure packages. I haven't used it myself, but it may make for a more
unified experience for many of these packages.

Just my two cents... Good luck.

Ryan



 Hi all,

 I know many of you use DFT calculations to help model EXAFS data for
 molecular compounds. Do you have recommendations for good computational
 chemistry packages, commercial or otherwise, to use for that purpose?

 --Scott Calvin
 Sarah Lawrence College



___
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov