[jira] (SUREFIRE-897) System.exit() in ForkedBooter might hang due to swing/windows bug

2012-08-06 Thread Kristian Rosenvold (JIRA)

[ 
https://jira.codehaus.org/browse/SUREFIRE-897?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=305661#comment-305661
 ] 

Kristian Rosenvold edited comment on SUREFIRE-897 at 8/7/12 12:35 AM:
--

Fixed in r1369951, thanks for the patch !

  was (Author: krosenvold):
Ficed in r1369951, thanks for the patch !
  
> System.exit() in ForkedBooter might hang due to swing/windows bug
> -
>
> Key: SUREFIRE-897
> URL: https://jira.codehaus.org/browse/SUREFIRE-897
> Project: Maven Surefire
>  Issue Type: Bug
>  Components: process forking
>Affects Versions: 2.12
> Environment: Windows, Java 6,7
>Reporter: Ralf Stuckert
>Assignee: Kristian Rosenvold
> Fix For: 2.12.2
>
> Attachments: ForkedBooter.patch
>
>
> Due to a bug in Swing on Windows (see 
> http://bugs.sun.com/bugdatabase/view_bug.do?bug_id=7071160) the forked 
> process may not respond to System.exit() in class ForkedBooter after excuting 
> swing tests on windows. This leads to a hanging build, and the only way to 
> resolve it, is to kill the hanging process.
> After all, sending Runtime.halt() will always stop the process. But since 
> this is not a clean shutdown (e.g. shutdown-hooks not running), this should 
> not be the default behaviour.
> As a workaround, you could start a daemon thread as a watchdog before calling 
> System.exit().
> The deamon sleeps for a certain time, let's say a minute. If it ever resumes 
> from sleeping, it means that the JVM is still running, so the System.exit() 
> was not completed in that time. Now it's time to call Runtime.halt() as a 
> last exit.
> We used this strategy to overcome the Swing bug (see attached patch).
> I guess it would be nice, if the timeout would be configurable.

--
This message is automatically generated by JIRA.
If you think it was sent incorrectly, please contact your JIRA administrators: 
https://jira.codehaus.org/secure/ContactAdministrators!default.jspa
For more information on JIRA, see: http://www.atlassian.com/software/jira




[jira] (SUREFIRE-897) System.exit() in ForkedBooter might hang due to swing/windows bug

2012-08-06 Thread Kristian Rosenvold (JIRA)

 [ 
https://jira.codehaus.org/browse/SUREFIRE-897?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Kristian Rosenvold closed SUREFIRE-897.
---

   Resolution: Fixed
Fix Version/s: 2.12.2
 Assignee: Kristian Rosenvold

Ficed in r1369951, thanks for the patch !

> System.exit() in ForkedBooter might hang due to swing/windows bug
> -
>
> Key: SUREFIRE-897
> URL: https://jira.codehaus.org/browse/SUREFIRE-897
> Project: Maven Surefire
>  Issue Type: Bug
>  Components: process forking
>Affects Versions: 2.12
> Environment: Windows, Java 6,7
>Reporter: Ralf Stuckert
>Assignee: Kristian Rosenvold
> Fix For: 2.12.2
>
> Attachments: ForkedBooter.patch
>
>
> Due to a bug in Swing on Windows (see 
> http://bugs.sun.com/bugdatabase/view_bug.do?bug_id=7071160) the forked 
> process may not respond to System.exit() in class ForkedBooter after excuting 
> swing tests on windows. This leads to a hanging build, and the only way to 
> resolve it, is to kill the hanging process.
> After all, sending Runtime.halt() will always stop the process. But since 
> this is not a clean shutdown (e.g. shutdown-hooks not running), this should 
> not be the default behaviour.
> As a workaround, you could start a daemon thread as a watchdog before calling 
> System.exit().
> The deamon sleeps for a certain time, let's say a minute. If it ever resumes 
> from sleeping, it means that the JVM is still running, so the System.exit() 
> was not completed in that time. Now it's time to call Runtime.halt() as a 
> last exit.
> We used this strategy to overcome the Swing bug (see attached patch).
> I guess it would be nice, if the timeout would be configurable.

--
This message is automatically generated by JIRA.
If you think it was sent incorrectly, please contact your JIRA administrators: 
https://jira.codehaus.org/secure/ContactAdministrators!default.jspa
For more information on JIRA, see: http://www.atlassian.com/software/jira




[jira] (SUREFIRE-897) System.exit() in ForkedBooter might hang due to swing/windows bug

2012-08-03 Thread Ralf Stuckert (JIRA)
Ralf Stuckert created SUREFIRE-897:
--

 Summary: System.exit() in ForkedBooter might hang due to 
swing/windows bug
 Key: SUREFIRE-897
 URL: https://jira.codehaus.org/browse/SUREFIRE-897
 Project: Maven Surefire
  Issue Type: Bug
  Components: process forking
Affects Versions: 2.12
 Environment: Windows, Java 6,7
Reporter: Ralf Stuckert
 Attachments: ForkedBooter.patch

Due to a bug in Swing on Windows (see 
http://bugs.sun.com/bugdatabase/view_bug.do?bug_id=7071160) the forked process 
may not respond to System.exit() in class ForkedBooter after excuting swing 
tests on windows. This leads to a hanging build, and the only way to resolve 
it, is to kill the hanging process.

After all, sending Runtime.halt() will always stop the process. But since this 
is not a clean shutdown (e.g. shutdown-hooks not running), this should not be 
the default behaviour.

As a workaround, you could start a daemon thread as a watchdog before calling 
System.exit().
The deamon sleeps for a certain time, let's say a minute. If it ever resumes 
from sleeping, it means that the JVM is still running, so the System.exit() was 
not completed in that time. Now it's time to call Runtime.halt() as a last exit.

We used this strategy to overcome the Swing bug (see attached patch).

I guess it would be nice, if the timeout would be configurable.


--
This message is automatically generated by JIRA.
If you think it was sent incorrectly, please contact your JIRA administrators: 
https://jira.codehaus.org/secure/ContactAdministrators!default.jspa