[jira] [Updated] (NIFI-12402) MonitorActivity generates inactivity indicator after it is started and threshold duration exceeds without actual activities

2024-01-19 Thread David Handermann (Jira)


 [ 
https://issues.apache.org/jira/browse/NIFI-12402?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

David Handermann updated NIFI-12402:

Fix Version/s: 1.25.0
   2.0.0-M2
 Assignee: Tan Luu
   Resolution: Fixed
   Status: Resolved  (was: Patch Available)

> MonitorActivity generates inactivity indicator after it is started and 
> threshold duration exceeds without actual activities
> ---
>
> Key: NIFI-12402
> URL: https://issues.apache.org/jira/browse/NIFI-12402
> Project: Apache NiFi
>  Issue Type: Improvement
>  Components: Extensions
>Affects Versions: 1.24.0
>Reporter: Tan Luu
>Assignee: Tan Luu
>Priority: Minor
>  Labels: patch-available
> Fix For: 1.25.0, 2.0.0-M2
>
>  Time Spent: 1h 20m
>  Remaining Estimate: 0h
>
> Even though there is no activity, a start or restart of MonitorActivity 
> processor produces an inactive flowfile after "Threshold Duration". This 
> behavior creates a false positive notification cause there was no actual 
> activity. The expected behavior is to only send an inactive indicator if 
> there is activity after the processor is started.



--
This message was sent by Atlassian Jira
(v8.20.10#820010)


[jira] [Updated] (NIFI-12402) MonitorActivity generates inactivity indicator after it is started and threshold duration exceeds without actual activities

2023-12-20 Thread Tan Luu (Jira)


 [ 
https://issues.apache.org/jira/browse/NIFI-12402?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Tan Luu updated NIFI-12402:
---
Labels: patch-available  (was: )
Status: Patch Available  (was: Open)

> MonitorActivity generates inactivity indicator after it is started and 
> threshold duration exceeds without actual activities
> ---
>
> Key: NIFI-12402
> URL: https://issues.apache.org/jira/browse/NIFI-12402
> Project: Apache NiFi
>  Issue Type: Improvement
>  Components: Extensions
>Affects Versions: 1.24.0
>Reporter: Tan Luu
>Priority: Minor
>  Labels: patch-available
>  Time Spent: 50m
>  Remaining Estimate: 0h
>
> Even though there is no activity, a start or restart of MonitorActivity 
> processor produces an inactive flowfile after "Threshold Duration". This 
> behavior creates a false positive notification cause there was no actual 
> activity. The expected behavior is to only send an inactive indicator if 
> there is activity after the processor is started.



--
This message was sent by Atlassian Jira
(v8.20.10#820010)


[jira] [Updated] (NIFI-12402) MonitorActivity generates inactivity indicator after it is started and threshold duration exceeds without actual activities

2023-12-20 Thread Tan Luu (Jira)


 [ 
https://issues.apache.org/jira/browse/NIFI-12402?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Tan Luu updated NIFI-12402:
---
Affects Version/s: 1.24.0
   (was: 1.23.2)

> MonitorActivity generates inactivity indicator after it is started and 
> threshold duration exceeds without actual activities
> ---
>
> Key: NIFI-12402
> URL: https://issues.apache.org/jira/browse/NIFI-12402
> Project: Apache NiFi
>  Issue Type: Improvement
>  Components: Extensions
>Affects Versions: 1.24.0
>Reporter: Tan Luu
>Priority: Minor
>  Time Spent: 50m
>  Remaining Estimate: 0h
>
> Even though there is no activity, a start or restart of MonitorActivity 
> processor produces an inactive flowfile after "Threshold Duration". This 
> behavior creates a false positive notification cause there was no actual 
> activity. The expected behavior is to only send an inactive indicator if 
> there is activity after the processor is started.



--
This message was sent by Atlassian Jira
(v8.20.10#820010)


[jira] [Updated] (NIFI-12402) MonitorActivity generates inactivity indicator after it is started and threshold duration exceeds without actual activities

2023-12-18 Thread Tan Luu (Jira)


 [ 
https://issues.apache.org/jira/browse/NIFI-12402?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Tan Luu updated NIFI-12402:
---
Description: Even though there is no activity, a start or restart of 
MonitorActivity processor produces an inactive flowfile after "Threshold 
Duration". This behavior creates a false positive notification cause there was 
no actual activity. The expected behavior is to only send an inactive indicator 
if there is activity after the processor is started.  (was: Even though there 
is no activity, a start or restart on MonitorActivity processor produces 
inactive alert after "Threshold Duration". This beahvior create a false 
positive no)

> MonitorActivity generates inactivity indicator after it is started and 
> threshold duration exceeds without actual activities
> ---
>
> Key: NIFI-12402
> URL: https://issues.apache.org/jira/browse/NIFI-12402
> Project: Apache NiFi
>  Issue Type: Improvement
>  Components: Extensions
>Affects Versions: 1.23.2
>Reporter: Tan Luu
>Priority: Minor
>  Time Spent: 0.5h
>  Remaining Estimate: 0h
>
> Even though there is no activity, a start or restart of MonitorActivity 
> processor produces an inactive flowfile after "Threshold Duration". This 
> behavior creates a false positive notification cause there was no actual 
> activity. The expected behavior is to only send an inactive indicator if 
> there is activity after the processor is started.



--
This message was sent by Atlassian Jira
(v8.20.10#820010)


[jira] [Updated] (NIFI-12402) MonitorActivity generates inactivity indicator after it is started and threshold duration exceeds without actual activities

2023-12-18 Thread Tan Luu (Jira)


 [ 
https://issues.apache.org/jira/browse/NIFI-12402?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Tan Luu updated NIFI-12402:
---
Description: Even though there is no activity, a start or restart on 
MonitorActivity processor produces inactive alert after "Threshold Duration". 
This beahvior create a false positive no  (was: MonitorActivity @OnScheduled 
method sets the "{*}inactive"{*} flag to false when it gets started so after 
the threshold duration without activity, an inactive indicator is created even 
if there is no actual activity.)

> MonitorActivity generates inactivity indicator after it is started and 
> threshold duration exceeds without actual activities
> ---
>
> Key: NIFI-12402
> URL: https://issues.apache.org/jira/browse/NIFI-12402
> Project: Apache NiFi
>  Issue Type: Improvement
>  Components: Extensions
>Affects Versions: 1.23.2
>Reporter: Tan Luu
>Priority: Minor
>  Time Spent: 0.5h
>  Remaining Estimate: 0h
>
> Even though there is no activity, a start or restart on MonitorActivity 
> processor produces inactive alert after "Threshold Duration". This beahvior 
> create a false positive no



--
This message was sent by Atlassian Jira
(v8.20.10#820010)