[kstars] [Bug 460375] Calibration Plot non-orthogonality

2022-10-22 Thread Hy
https://bugs.kde.org/show_bug.cgi?id=460375

Hy  changed:

   What|Removed |Added

 CC||hymu...@gmail.com
 Status|REPORTED|CONFIRMED
 Ever confirmed|0   |1

--- Comment #5 from Hy  ---
Yes, it's true. In fact I intentionally broke it in commit
https://invent.kde.org/education/kstars/-/commit/77c4b156d5de91f04c461af41195ee11df158daa
where I chose to make the calibration plot non-square (non-equal x and y axes
scales) in order to make the drift target square. I wish I knew how to make
both square.  I prioritized the drift target over the calibration plot.

You can make it square by resizing it or pulling the divider left or right.

Doesn't seem to be a way to mark a bug as "don't know how to fix"!

-- 
You are receiving this mail because:
You are watching all bug changes.

[kstars] [Bug 460375] Calibration Plot non-orthogonality

2022-10-15 Thread Jean-Claude
https://bugs.kde.org/show_bug.cgi?id=460375

--- Comment #4 from Jean-Claude  ---
Created attachment 152861
  --> https://bugs.kde.org/attachment.cgi?id=152861=edit
Guiding

Yes I'm using an OAG .
I repeated the guiding in KStars 360 and KStars 361 this evening and I got the
same results (see attachment "Guiding") : non-orthogonality in the KStars 361
calibration plot

-- 
You are receiving this mail because:
You are watching all bug changes.

[kstars] [Bug 460375] Calibration Plot non-orthogonality

2022-10-15 Thread Jasem Mutlaq
https://bugs.kde.org/show_bug.cgi?id=460375

--- Comment #3 from Jasem Mutlaq  ---
If this is using OAG, then the setup is indeed correct.

-- 
You are receiving this mail because:
You are watching all bug changes.

[kstars] [Bug 460375] Calibration Plot non-orthogonality

2022-10-14 Thread Jean-Claude
https://bugs.kde.org/show_bug.cgi?id=460375

--- Comment #2 from Jean-Claude  ---
Created attachment 152796
  --> https://bugs.kde.org/attachment.cgi?id=152796=edit
My trains

Thanks for the suggestion and I checked again my trains (see attachment) :
I use for guiding the secondary train including : 
- as guiding camera "ASI CCD ASI174MM" 
- as guider "EdgeHD" (a custom driver created for the config 2800@F/10.0

-- 
You are receiving this mail because:
You are watching all bug changes.

[kstars] [Bug 460375] Calibration Plot non-orthogonality

2022-10-13 Thread Jasem Mutlaq
https://bugs.kde.org/show_bug.cgi?id=460375

--- Comment #1 from Jasem Mutlaq  ---
Check Optical Train and make sure you selected the correct guider. Guider is
NOT camera, guider is the the device that *receives the correction pulses* like
your mount for example.

-- 
You are receiving this mail because:
You are watching all bug changes.