[plasmashell] [Bug 450062] Plasma 5.25 + Wayland: When disconnecting 2nd monitor, icon positions get reset

2023-04-18 Thread Nate Graham
https://bugs.kde.org/show_bug.cgi?id=450062

Nate Graham  changed:

   What|Removed |Added

Version|5.27.4  |5.27.0
 Status|REOPENED|RESOLVED
   Platform|Neon|openSUSE
 Resolution|--- |FIXED

--- Comment #16 from Nate Graham  ---
Even though the symptoms may look the same, the root cause of your issue is
very likely to be different from the root cause of this issue, and we should
handle it differently. So please submit a new bug report instead of re-opening
an old one.  Thanks for understanding!

-- 
You are receiving this mail because:
You are watching all bug changes.

[plasmashell] [Bug 450062] Plasma 5.25 + Wayland: When disconnecting 2nd monitor, icon positions get reset

2023-04-18 Thread C. Kimna
https://bugs.kde.org/show_bug.cgi?id=450062

--- Comment #15 from C. Kimna  ---
Plasma version 5.27.4 KDE Neon

-- 
You are receiving this mail because:
You are watching all bug changes.

[plasmashell] [Bug 450062] Plasma 5.25 + Wayland: When disconnecting 2nd monitor, icon positions get reset

2023-04-18 Thread C. Kimna
https://bugs.kde.org/show_bug.cgi?id=450062

C. Kimna  changed:

   What|Removed |Added

 CC||ki...@gmx.de
Version|5.27.0  |5.27.4
   Platform|Other   |Neon
 Status|RESOLVED|REOPENED
 Resolution|FIXED   |---

--- Comment #14 from C. Kimna  ---
Same here, since some months. After switching signal input from monitor and
back to KDE
all icons positions are reset. On Wayland AND xorg.

kscreen-console monitor displays while switching to other signal:
Priorities changed: QMap()
qt.qpa.wayland: Creating a fake screen in order for Qt not to crash


I've tested disabling kscreen, but the same issue here.

-- 
You are receiving this mail because:
You are watching all bug changes.

[plasmashell] [Bug 450062] Plasma 5.25 + Wayland: When disconnecting 2nd monitor, icon positions get reset

2023-02-14 Thread dr0phx
https://bugs.kde.org/show_bug.cgi?id=450062

dr0phx  changed:

   What|Removed |Added

 CC||re...@mailbox.org

--- Comment #13 from dr0phx  ---
(In reply to NIk from comment #11)
> (In reply to Nate Graham from comment #10)
> > Yes, I can reproduce it too. It's quite bad. The team is working on a whole
> > new, better, simpler way of assigning Plasma containments to screens which
> > will fix this automatically. See Bug 450068. Marking this as a duplicate
> > since fixing that will automatically fix this too.
> > 
> > *** This bug has been marked as a duplicate of bug 450068 ***
> 
> 5.27 - not fixed .. :(
> Just tested it. Switched to Wayland, logged in, all icons were first GONE,
> then logged out and in again and every icon got shuffled around. 
> Theres something the coders arent seeing I guess. Maybe it has to do with
> the fact Im using an Intel iGPU? I dont know ..

Hi, I just created an account - maybe my information is useful. I can also
reproduce the bug. Its not iGPU related, I use an AMD RX550 and two monitors,
which I switch (A or B mode so to say) using a HDMI switch. Same thing happens.
Icons disappear, after re-login they are in the left upper corner.

-- 
You are receiving this mail because:
You are watching all bug changes.

[plasmashell] [Bug 450062] Plasma 5.25 + Wayland: When disconnecting 2nd monitor, icon positions get reset

2023-02-14 Thread Nate Graham
https://bugs.kde.org/show_bug.cgi?id=450062

Nate Graham  changed:

   What|Removed |Added

   Version Fixed In||5.27
 Resolution|--- |FIXED
 Status|REOPENED|RESOLVED

--- Comment #12 from Nate Graham  ---
So the issue you're reporting now is different from the one you originally
reported, and it should actually be the same as Bug 465536 which was just fixed
today for Plasma 5.27.1.

-- 
You are receiving this mail because:
You are watching all bug changes.

[plasmashell] [Bug 450062] Plasma 5.25 + Wayland: When disconnecting 2nd monitor, icon positions get reset

2023-02-14 Thread NIk
https://bugs.kde.org/show_bug.cgi?id=450062

NIk  changed:

   What|Removed |Added

 Status|RESOLVED|REOPENED
 Resolution|DUPLICATE   |---

--- Comment #11 from NIk  ---
(In reply to Nate Graham from comment #10)
> Yes, I can reproduce it too. It's quite bad. The team is working on a whole
> new, better, simpler way of assigning Plasma containments to screens which
> will fix this automatically. See Bug 450068. Marking this as a duplicate
> since fixing that will automatically fix this too.
> 
> *** This bug has been marked as a duplicate of bug 450068 ***

5.27 - not fixed .. :(
Just tested it. Switched to Wayland, logged in, all icons were first GONE, then
logged out and in again and every icon got shuffled around. 
Theres something the coders arent seeing I guess. Maybe it has to do with the
fact Im using an Intel iGPU? I dont know ..

-- 
You are receiving this mail because:
You are watching all bug changes.

[plasmashell] [Bug 450062] Plasma 5.25 + Wayland: When disconnecting 2nd monitor, icon positions get reset

2023-02-14 Thread NIk
https://bugs.kde.org/show_bug.cgi?id=450062

NIk  changed:

   What|Removed |Added

Version|git-stable-Plasma/5.26  |5.27.0
   Version Fixed In|5.25|

-- 
You are receiving this mail because:
You are watching all bug changes.

[plasmashell] [Bug 450062] Plasma 5.25 + Wayland: When disconnecting 2nd monitor, icon positions get reset

2022-10-14 Thread Nate Graham
https://bugs.kde.org/show_bug.cgi?id=450062

Nate Graham  changed:

   What|Removed |Added

 Resolution|--- |DUPLICATE
 Status|REOPENED|RESOLVED

--- Comment #10 from Nate Graham  ---
Yes, I can reproduce it too. It's quite bad. The team is working on a whole
new, better, simpler way of assigning Plasma containments to screens which will
fix this automatically. See Bug 450068. Marking this as a duplicate since
fixing that will automatically fix this too.

*** This bug has been marked as a duplicate of bug 450068 ***

-- 
You are receiving this mail because:
You are watching all bug changes.

[plasmashell] [Bug 450062] Plasma 5.25 + Wayland: When disconnecting 2nd monitor, icon positions get reset

2022-10-14 Thread NIk
https://bugs.kde.org/show_bug.cgi?id=450062

NIk  changed:

   What|Removed |Added

Version|5.25.0  |git-stable-Plasma/5.26

--- Comment #9 from NIk  ---
5.26, retested, still not fixed .. :)

-- 
You are receiving this mail because:
You are watching all bug changes.

[plasmashell] [Bug 450062] Plasma 5.25 + Wayland: When disconnecting 2nd monitor, icon positions get reset

2022-08-29 Thread Jason
https://bugs.kde.org/show_bug.cgi?id=450062

--- Comment #8 from Jason  ---
(In reply to Jason from comment #7)
> Same thing happens on my laptop when I connect to an external monitor, the
> desktop icons get reset after disconnecting the monitor.
> 
> This only happens to me when using 'Switch to Extenal Monitor' ie Laptop LCD
> off, external monitor on.
> This does not happen if I mirror (unify outputs) the display to the external
> monitor or extend the monitor 'Extend to Left/Right'
> And obviously, this only happens in wayland.
> 
> Using Opensuse Tumbleweed, KDE 5.24.5, Kernel 5.18.15, GPU: Intel HD
> Graphics 620

Sorry, I meant KDE 5.25.4. Also, couldn't find the edit message button!

-- 
You are receiving this mail because:
You are watching all bug changes.

[plasmashell] [Bug 450062] Plasma 5.25 + Wayland: When disconnecting 2nd monitor, icon positions get reset

2022-08-29 Thread bugzilla_noreply
https://bugs.kde.org/show_bug.cgi?id=450062

jason600.gro...@gmail.com changed:

   What|Removed |Added

 CC||jason600.gro...@gmail.com

--- Comment #7 from jason600.gro...@gmail.com ---
Same thing happens on my laptop when I connect to an external monitor, the
desktop icons get reset after disconnecting the monitor.

This only happens to me when using 'Switch to Extenal Monitor' ie Laptop LCD
off, external monitor on.
This does not happen if I mirror (unify outputs) the display to the external
monitor or extend the monitor 'Extend to Left/Right'
And obviously, this only happens in wayland.

Using Opensuse Tumbleweed, KDE 5.24.5, Kernel 5.18.15, GPU: Intel HD Graphics
620

-- 
You are receiving this mail because:
You are watching all bug changes.

[plasmashell] [Bug 450062] Plasma 5.25 + Wayland: When disconnecting 2nd monitor, icon positions get reset

2022-06-15 Thread NIk
https://bugs.kde.org/show_bug.cgi?id=450062

NIk  changed:

   What|Removed |Added

Summary|Plasma 5.24 + Wayland: When |Plasma 5.25 + Wayland: When
   |disconnecting 2nd monitor,  |disconnecting 2nd monitor,
   |icon positions get reset|icon positions get reset

-- 
You are receiving this mail because:
You are watching all bug changes.