Re: Update LabView 6.1 to 7.0; error 1003

2004-05-12 Thread georgie
Hi,

thank you for your E-Mail. I have found the problem. In a SubVi I have
a reference as an Input. The Output of this SubVi was the Indicator,
where the reference is related to. After I have replaced the Indicator
with a Local Variable to this Indicator, I could build the executable.
But this problem occurs only with LabView 7.0. It don't occur in the
development environment.

Thanks

Georg Lampe



Re: Update LabView 6.1 to 7.0; error 1003

2004-05-11 Thread peterguy
Hi,

the error 1003 normally indicates a not runnable subVI.
It wonder if the VI is running under LabVIEW 7 or if the error only
occures when building an executable? Perhaps you can post your VI, so
that I can check it on my computer?
A few weeks ago, I had a similar problem running a LV6.1 VI under LV7.
At that time the error was that the connections of a VISA-VI had
changed, so that I had to wire one additional connection in LV7, but
not in LV6.1.

regards,

Peter Weber
NI Germany