Re: Raid, resync and hotspare

2005-07-13 Thread Louis-David Mitterrand
On Tue, Jul 12, 2005 at 05:33:08PM +0200, Laurent Caron wrote:
> Hi,
> 
> I recently moved a server from old disks to now ones and added a 
> hotspare (mdadm /dev/md1 -a /dev/sdf2)
> 
> the hotspare appears in  /proc/mdstat
> 
> Personalities : [linear] [raid0] [raid1] [raid5] [multipath] [raid6]
> md1 : active raid5 sdf2[5] sde2[4] sdd2[3] sdc2[2] sdb2[1] sda2[0]
>  285699584 blocks level 5, 64k chunk, algorithm 2 [5/5] [U]
> 
> 
> when I fail a disk, mdadm does *not* send me any warning.

>From the mdamd man page:

Only  Fail , FailSpare , DegradedArray , and TestMessage cause Email to 
be
sent.

Your event is "SpareActive" which does not trigger an alert mail,
however all events can be reported through the "--program" switch:

All events cause the program to be run.  The program  is  run with
two or  three  arguments,  they  being the event name, the array
device and possibly a second device.

> Only at the second failure when the array is in degraded state I receive 
> a warning.

> How may I receive a warning when the hotspare disk has been used to cope 
> with a disk failure?

--program "my_mail_script.sh"

#!/bin/sh
nail -s "$1 event detected on device $2 $3" root < EOF

Dear admin,

You array seems to have suffered to breakage:

A $1 event was received on for device $2 $3.

Fix it ASAP!

Regards,

EOF

-- 
This space for rent.
-
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html


Raid, resync and hotspare

2005-07-12 Thread Laurent CARON

Hi,

I recently moved a server from old disks to now ones and added a 
hotspare (mdadm /dev/md1 -a /dev/sdf2)


the hotspare appears in  /proc/mdstat

Personalities : [linear] [raid0] [raid1] [raid5] [multipath] [raid6]
md1 : active raid5 sdf2[5] sde2[4] sdd2[3] sdc2[2] sdb2[1] sda2[0]
 285699584 blocks level 5, 64k chunk, algorithm 2 [5/5] [U]


when I fail a disk, mdadm does *not* send me any warning.

Only at the second failure when the array is in degraded state I receive 
a warning.


How may I receive a warning when the hotspare disk has been used to cope 
with a disk failure?


Thanks
-
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to [EMAIL PROTECTED]