Re: [neonixie-l] Nixie doctor needed.

2010-10-27 Thread Shane Ellis
IN-14, very good!  I connected the second tube the same way I connected the
first, and the other tube works fine.  I coded the second tube the same as
the first, and I get all this blobbiness, and blue spots.  I'll check
voltages, and report back.
Shane

On Wed, Oct 27, 2010 at 8:17 AM, jb-electronics  wrote:

> Hello Shane,
>
> hmm, maybe the driver does not work well enough? If the digits that are
> supposed to be "off" have a potential that is near ground, they might light
> up. Check the voltage on the faulty digits accross ground.
>
> My first guess was - without seeing the pictures - that you had tried to
> drive a biquinary Nixie tube as a normal one. Biquinary Nixie tubes have 0
> and 1, 2 and 3, 4 and 5, you know, all even and odd numbers connected in
> parallel with two anodes. This way they have a standard noval socket, but
> require a different kind if handling. But it looks o me as though your tube
> was an IN-14, right?
>
> Jens
>
>
> --
> You received this message because you are subscribed to the Google Groups
> "neonixie-l" group.
> To post to this group, send an email to neonixi...@googlegroups.com.
> To unsubscribe from this group, send email to
> neonixie-l+unsubscr...@googlegroups.com
> .
> For more options, visit this group at
> http://groups.google.com/group/neonixie-l?hl=en-GB.
>
>

-- 
You received this message because you are subscribed to the Google Groups 
"neonixie-l" group.
To post to this group, send an email to neonixi...@googlegroups.com.
To unsubscribe from this group, send email to 
neonixie-l+unsubscr...@googlegroups.com.
For more options, visit this group at 
http://groups.google.com/group/neonixie-l?hl=en-GB.



Re: [neonixie-l] Nixie doctor needed.

2010-10-27 Thread jb-electronics

Hello Shane,

hmm, maybe the driver does not work well enough? If the digits that are 
supposed to be "off" have a potential that is near ground, they might 
light up. Check the voltage on the faulty digits accross ground.


My first guess was - without seeing the pictures - that you had tried to 
drive a biquinary Nixie tube as a normal one. Biquinary Nixie tubes have 
0 and 1, 2 and 3, 4 and 5, you know, all even and odd numbers connected 
in parallel with two anodes. This way they have a standard noval socket, 
but require a different kind if handling. But it looks o me as though 
your tube was an IN-14, right?


Jens

--
You received this message because you are subscribed to the Google Groups 
"neonixie-l" group.
To post to this group, send an email to neonixi...@googlegroups.com.
To unsubscribe from this group, send email to 
neonixie-l+unsubscr...@googlegroups.com.
For more options, visit this group at 
http://groups.google.com/group/neonixie-l?hl=en-GB.



[neonixie-l] Nixie doctor needed.

2010-10-27 Thread Shane Ellis
I moved up to a larger PICAXE, all is going well, except, I went to
two tubes, and the new tube is...well... sickly looking.  I double,
and quintuple checked the connections, but as you will see in the
attached photos, something is wrong.  Half the digits light up fine
0-4, but 5-9, well, look terrible.  they half light, and have bright
blue spots at several points on the digit.  Bad tube?  Internal short
in the tube?
Thanks everyone, and sorry if I post too much, my desire for
illuminated tubes is great!
Shane

http://s299.photobucket.com/albums/mm286/mimewar/Nixie%20and%20programming/

-- 
You received this message because you are subscribed to the Google Groups 
"neonixie-l" group.
To post to this group, send an email to neonixi...@googlegroups.com.
To unsubscribe from this group, send email to 
neonixie-l+unsubscr...@googlegroups.com.
For more options, visit this group at 
http://groups.google.com/group/neonixie-l?hl=en-GB.