Hi,
I have been testing the 0.12.0 RC1 and Im having problems with it when using MyEID cards. I traced the problem, and found out that the setting max_recv_size in opensc.conf file for the reader pcsc has no effect, the value seems to be always 0, and therefore the limitations wont apply. I think this is an issue only for T=1 cards. I created a new ticket for this, #269 (http://www.opensc-project.org/opensc/ticket/269) Regards, Toni