On Tue, Jan 16, 2018 at 04:50:21PM +0100, Clemens Gruber wrote:
> Signed-off-by: Clemens Gruber
You need to update host-dbus as well:
[...]
-
target: host-dbus.prepare
-
configure: error: unrecognized options: --disable-compiler-coverage,
--enable-abstract-sockets
[...]
Michael
> ---
> rules/dbus.make | 13 +++--
> 1 file changed, 7 insertions(+), 6 deletions(-)
>
> diff --git a/rules/dbus.make b/rules/dbus.make
> index bbf602625..1ba7ad3d2 100644
> --- a/rules/dbus.make
> +++ b/rules/dbus.make
> @@ -18,8 +18,8 @@ PACKAGES-$(PTXCONF_DBUS) += dbus
> #
> # Paths and names
> #
> -DBUS_VERSION := 1.10.24
> -DBUS_MD5 := d548ae16f9a3268fe4650ccc86a3f06f
> +DBUS_VERSION := 1.12.2
> +DBUS_MD5 := 3361456cadb99aa6601bed5b48964254
> DBUS := dbus-$(DBUS_VERSION)
> DBUS_SUFFIX := tar.gz
> DBUS_URL :=
> http://dbus.freedesktop.org/releases/dbus/$(DBUS).$(DBUS_SUFFIX)
> @@ -38,11 +38,10 @@ DBUS_CONF_TOOL:= autoconf
> DBUS_CONF_OPT:= \
> $(CROSS_AUTOCONF_USR) \
> --enable-silent-rules \
> + --disable-developer \
> + --disable-debug \
> $(GLOBAL_LARGE_FILE_OPTION) \
> --disable-static \
> - --disable-compiler-coverage \
> - --enable-compiler-optimisations \
> - --disable-developer \
> --disable-ansi \
> --disable-verbose-mode \
> --disable-asserts \
> @@ -50,7 +49,6 @@ DBUS_CONF_OPT := \
> --disable-xml-docs \
> --disable-doxygen-docs \
> --disable-ducktype-docs \
> - --enable-abstract-sockets=yes \
> --$(call ptx/endis, PTXCONF_DBUS_SELINUX)-selinux \
> --disable-apparmor \
> --disable-libaudit \
> @@ -63,9 +61,12 @@ DBUS_CONF_OPT := \
> --disable-modular-tests \
> --disable-tests \
> --disable-installed-tests \
> + --disable-code-coverage \
> --enable-epoll \
> --$(call ptx/endis, PTXCONF_DBUS_X)-x11-autolaunch \
> + --disable-compile-warnings \
> --disable-Werror \
> + --disable-relocation \
> --disable-stats \
> --$(call ptx/endis, PTXCONF_DBUS_SYSTEMD)-user-session \
> --with-dbus-user=messagebus \
> --
> 2.15.1
>
>
> ___