Hi
On Fri, Nov 25, 2022 at 7:41 PM Philippe Mathieu-Daudé
wrote:
>
> Only 3 command types are logged: no need to call qxl_phys2virt()
> for the other types.
>
> Signed-off-by: Philippe Mathieu-Daudé
> ---
> hw/display/qxl-logger.c | 11 +++
> 1 file changed, 11 insertions(+)
>
> diff --git a/hw/display/qxl-logger.c b/hw/display/qxl-logger.c
> index 68bfa47568..1bcf803db6 100644
> --- a/hw/display/qxl-logger.c
> +++ b/hw/display/qxl-logger.c
> @@ -247,6 +247,16 @@ int qxl_log_command(PCIQXLDevice *qxl, const char *ring,
> QXLCommandExt *ext)
> qxl_name(qxl_type, ext->cmd.type),
> compat ? "(compat)" : "");
>
> +switch (ext->cmd.type) {
> +case QXL_CMD_DRAW:
> +break;
> +case QXL_CMD_SURFACE:
> +break;
> +case QXL_CMD_CURSOR:
> +break;
> +default:
> +goto out;
> +}
That's a quite verbose way to repeat the case list below. Furthermore,
it shouldn't hurt to call qxl_phys2virt() next.
> data = qxl_phys2virt(qxl, ext->cmd.data, ext->group_id);
But I understand better the change looking at patch 3, where you
introduce the size argument. Maybe mention the coming change in the
commit message?
Reviewed-by: Marc-André Lureau
> if (!data) {
> return 1;
> @@ -269,6 +279,7 @@ int qxl_log_command(PCIQXLDevice *qxl, const char *ring,
> QXLCommandExt *ext)
> qxl_log_cmd_cursor(qxl, data, ext->group_id);
> break;
> }
> +out:
> fprintf(stderr, "\n");
> return 0;
> }
> --
> 2.38.1
>
>
--
Marc-André Lureau