Re: (RADIATOR) Multiple STOP records with AS5300

2000-02-21 Thread Hugh Irvine


Hello Lufti -

On Tue, 22 Feb 2000, Lutfi YUNUSOGLU wrote:
> 
LogDir  /var/radius
Foreground
LogStdout
Trace   3
DbDir   /usr/local/etc/
DictionaryFile %D/dictionary
PidFile /tmp/radiusd.pid
AuthPort1645
AcctPort1646
RewriteUsername tr/-A-Za-z0-9\.\@//cd
SnmpgetProg /usr/local/bin/snmpget
# You will probably want to change this to suit your site.


Secret  mysecret
#   DupInterval 0
#   IgnoreAcctSignature
SNMPCommunity community
NasType Cisco


I would be interested to see a Trace 4 debug, to check the timestamps on the
various events that are occuring. If Radiator is responding correctly to the
accounting packets within a reasonable amount of time (sub-second), then I
would suspect a bug in the Cisco IOS. You could also turn on the Cisco's debug
mode (don't remember the exact syntax - something like "debug aaa ") to try
and see what it thinks is going on. I would also suggest you check the wire
with tcpdump or snoop or a LAN sniffer to verify that the packets are indeed
being transmitted.

hth

Hugh


-- 
Radiator: the most portable, flexible and configurable RADIUS server
anywhere. SQL, proxy, DBM, files, LDAP, NIS+, password, NT, Emerald,
Platypus, Freeside, TACACS+, PAM, external, etc etc on Unix, Win95/8,
NT, Rhapsody

===
Archive at http://www.thesite.com.au/~radiator/
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.



Re: (RADIATOR) Multiple STOP records with AS5300

2000-02-21 Thread Volker Klau

Hi,

> We use Cisco AS 5300 (Ver. 12.0.5 T 2) and Radiator 2.14 (AuthBy SQL).
> When I look to the acounting data I see for most of the session's multiple stop 
>records. In cisco I have 60 sec. timeout for acct and as retransit value 2.
> 
> Any clue?

an answer is for me also very interesting.
We see the same behavior on our 58er running 12.0(7 T)

As far as i've seen, should this not be a problem of radiatorperfomance.

May be an IOS problem?
 
> Best Regards
> Lutfi
> 
> PS: My network is 100Tx

Best Regards,

  Volker

+ KomTel Gesellschaft fuer
+ Kommunikations- und
+ Informationsdienste mbH
+