Re: [TANKS] Series different AH rating for SLA bat

2011-01-24 Thread Thomas Lum

The good money is on this...

http://stores.headway-headquarters.com/-strse-69/HEADWAY-24V-16A-BATTERY/Detail.bok

Sure it's 8 times more expensive than SLA but it's 9 times cooler!


On Jan 24, 2011, at 03:53 PM, Steve Tyng  wrote:


Enzo wrote:

> I want to produce 24 volts with the least battery weight..


Buy eight of these and voila!

http://stores.headway-headquarters.com/-strse-3/Headway%2C-batteries%2C-EV%2C-electric/Detail.bok


Steve

--
You are currently subscribed to the "R/C Tank Combat" group.
To post a message, send email to rctankcombat@googlegroups.com
To unsubscribe, send email to rctankcombat-unsubscr...@googlegroups.com
Visit the group at http://groups.google.com/group/rctankcombat


--
You are currently subscribed to the "R/C Tank Combat" group.
To post a message, send email to rctankcombat@googlegroups.com
To unsubscribe, send email to rctankcombat-unsubscr...@googlegroups.com
Visit the group at http://groups.google.com/group/rctankcombat


Re: [TANKS] Series different AH rating for SLA bat

2011-01-24 Thread Frank Pittelli
With that arrangement of batteries in series, you'll get 24V for less 
than half the time two 18AH batteries would have lasted.  When the 7AH 
battery is depleted, the total voltage will rapidly decline.


Frank P.

On 1/24/2011 12:13 AM, Enzo Salas wrote:

Hi,

Is it possible to series 1 pc 12volt 18 AH SLA battery and 1 pc 12volt
7AH SLA bat?

I want to produce 24 volts with the least battery weight..


Regards,
Enzo



--
You are currently subscribed to the "R/C Tank Combat" group.
To post a message, send email to rctankcombat@googlegroups.com
To unsubscribe, send email to rctankcombat-unsubscr...@googlegroups.com
Visit the group at http://groups.google.com/group/rctankcombat


Re: [TANKS] Series different AH rating for SLA bat

2011-01-24 Thread Gregory Kampjes
It should be possible. I think you might only get 7 Ah out of it though, but
I'm not sure.

-Gregory

On Mon, Jan 24, 2011 at 6:13 PM, Enzo Salas  wrote:

> Hi,
>
> Is it possible to series 1 pc 12volt 18 AH SLA battery and 1 pc 12volt
> 7AH SLA bat?
>
> I want to produce 24 volts with the least battery weight..
>
>
> Regards,
> Enzo
>
> --
> You are currently subscribed to the "R/C Tank Combat" group.
> To post a message, send email to rctankcombat@googlegroups.com
> To unsubscribe, send email to rctankcombat-unsubscr...@googlegroups.com
> Visit the group at http://groups.google.com/group/rctankcombat
>

-- 
You are currently subscribed to the "R/C Tank Combat" group.
To post a message, send email to rctankcombat@googlegroups.com
To unsubscribe, send email to rctankcombat-unsubscr...@googlegroups.com
Visit the group at http://groups.google.com/group/rctankcombat


[TANKS] Series different AH rating for SLA bat

2011-01-23 Thread Enzo Salas
Hi,

Is it possible to series 1 pc 12volt 18 AH SLA battery and 1 pc 12volt
7AH SLA bat?

I want to produce 24 volts with the least battery weight..


Regards,
Enzo

-- 
You are currently subscribed to the "R/C Tank Combat" group.
To post a message, send email to rctankcombat@googlegroups.com
To unsubscribe, send email to rctankcombat-unsubscr...@googlegroups.com
Visit the group at http://groups.google.com/group/rctankcombat