[RE-wrenches] [1] Evergreen 205

2011-06-13 Thread Dana
Hey all,

 

I am looking for [1] Evergreen 205w (A) PV module for a
friend to fill out the roof on his RV. I told him to just
get it back when now he wishes he had.

 

Let me know off list. Thanks.

 

Dana Orzel

Great Solar Works, Inc

E - d...@solarwork.com

V - 970.626.5253

F - 970.626.4140

C - 970.209.4076

web - www.solarwork.com

 

Responsible Technologies for Responsible People since 1988

Do not ever believe anything, but seriously trust through
action.

 

___
List sponsored by Home Power magazine

List Address: RE-wrenches@lists.re-wrenches.org

Options  settings:
http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org

List-Archive: http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org

List rules  etiquette:
www.re-wrenches.org/etiquette.htm

Check out participant bios:
www.members.re-wrenches.org



[RE-wrenches] 3,200AH Battery Bank?

2011-06-13 Thread All Solar, Inc. Jeremy Amy Rodriguez
Wrenches,
I am looking for some advice on battery bank sizing.  

I am using a C/20 rate so 160A charge = 3200 AH correct?  

Looks Like 4v - 1350Ah batteries.  3 strings??

Thanks in advance!





All Solar Inc.
Jeremy and Amy Rodriguez
1463 M St
Penrose, CO 81240
www.asolarelectric.com
Phone 719-372-3808
Fax 719-372-3804
Email allso...@scswifi.net
Email allso...@live.com___
List sponsored by Home Power magazine

List Address: RE-wrenches@lists.re-wrenches.org

Options  settings:
http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org

List-Archive: http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org

List rules  etiquette:
www.re-wrenches.org/etiquette.htm

Check out participant bios:
www.members.re-wrenches.org



Re: [RE-wrenches] 3,200AH Battery Bank?

2011-06-13 Thread William Miller

Jeremy:

Here's a photo of a 4,400 AH bank.  I believe it is three strings, but 
don't quote me, it's been awhile.  If you need, contact me off list for 
specifications.


http://millersolar.com/Portfolio/Commercial/Cal_Trans/_cal_trans_gorda.html


William




At 04:29 PM 6/13/2011, you wrote:

Wrenches,
I am looking for some advice on battery bank sizing.

I am using a C/20 rate so 160A charge = 3200 AH correct?

Looks Like 4v - 1350Ah batteries.  3 strings??

Thanks in advance!





All Solar Inc.
Jeremy and Amy Rodriguez
1463 M St
Penrose, CO 81240
http://www.asolarelectric.comwww.asolarelectric.com
Phone 719-372-3808
Fax 719-372-3804
Email mailto:allso...@scswifi.netallso...@scswifi.net
Email mailto:allso...@live.comallso...@live.com
___
List sponsored by Home Power magazine

List Address: RE-wrenches@lists.re-wrenches.org

Options  settings:
http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org

List-Archive: 
http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org


List rules  etiquette:
www.re-wrenches.org/etiquette.htm

Check out participant bios:
www.members.re-wrenches.org

No virus found in this message.
Checked by AVG - www.avg.com
Version: 10.0.1375 / Virus Database: 1513/3701 - Release Date: 06/13/11


William Miller
Miller Solar
Voice :805-438-5600
email: will...@millersolar.com
http://millersolar.com
License No. C-10-773985
___
List sponsored by Home Power magazine

List Address: RE-wrenches@lists.re-wrenches.org

Options  settings:
http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org

List-Archive: http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org

List rules  etiquette:
www.re-wrenches.org/etiquette.htm

Check out participant bios:
www.members.re-wrenches.org



Re: [RE-wrenches] 3,200AH Battery Bank?

2011-06-13 Thread Mark Frye
The question is not well addressed without knowing the nominal dc system
voltage.
 
Mark Frye 
Berkeley Solar Electric Systems 
303 Redbud Way 
Nevada City,  CA 95959 
(530) 401-8024 
 http://www.berkeleysolar.com/ www.berkeleysolar.com  
 

  _  

From: re-wrenches-boun...@lists.re-wrenches.org
[mailto:re-wrenches-boun...@lists.re-wrenches.org] On Behalf Of All Solar,
Inc. Jeremy  Amy Rodriguez
Sent: Monday, June 13, 2011 4:30 PM
To: RE-wrenches
Subject: [RE-wrenches] 3,200AH Battery Bank?


Wrenches,
I am looking for some advice on battery bank sizing.  
 
I am using a C/20 rate so 160A charge = 3200 AH correct?  
 
Looks Like 4v - 1350Ah batteries.  3 strings??
 
Thanks in advance!
 
 
 
 
 
All Solar Inc.
Jeremy and Amy Rodriguez
1463 M St
Penrose, CO 81240
www.asolarelectric.com
Phone 719-372-3808
Fax 719-372-3804
Email allso...@scswifi.net
Email allso...@live.com
___
List sponsored by Home Power magazine

List Address: RE-wrenches@lists.re-wrenches.org

Options  settings:
http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org

List-Archive: http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org

List rules  etiquette:
www.re-wrenches.org/etiquette.htm

Check out participant bios:
www.members.re-wrenches.org



[RE-wrenches] smart meters/bidirectional

2011-06-13 Thread jay peltz
HI All,

Say are the new California smart meters bi-directional?

A recent install test showed the meter resister a negative watt indication, 
but I couldn't run it long enough to see if the KWH went backwards.

thanks,

jay

peltz power

___
List sponsored by Home Power magazine

List Address: RE-wrenches@lists.re-wrenches.org

Options  settings:
http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org

List-Archive: http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org

List rules  etiquette:
www.re-wrenches.org/etiquette.htm

Check out participant bios:
www.members.re-wrenches.org



Re: [RE-wrenches] smart meters/bidirectional

2011-06-13 Thread Mark Frye
Jay,

I recently ran a smartmeter prior to changing out to a NEMS meter here in
California (PGE). for test purposes only of course

I saw the energy flow indicator reverese direction and after a period of
time, the kWH reading also decreased so I was pretty confident that the
smartmeter was behaving the same as to old dics meters.
 
Mark Frye
Berkeley Solar Electric Systems
303 Redbud Way
Nevada City,  CA 95959
(530) 401-8024
www.berkeleysolar.com 

-Original Message-
From: re-wrenches-boun...@lists.re-wrenches.org
[mailto:re-wrenches-boun...@lists.re-wrenches.org] On Behalf Of jay peltz
Sent: Monday, June 13, 2011 8:10 PM
To: RE-wrenches
Subject: [RE-wrenches] smart meters/bidirectional

HI All,

Say are the new California smart meters bi-directional?

A recent install test showed the meter resister a negative watt
indication, but I couldn't run it long enough to see if the KWH went
backwards.

thanks,

jay

peltz power

___
List sponsored by Home Power magazine

List Address: RE-wrenches@lists.re-wrenches.org

Options  settings:
http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org

List-Archive:
http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org

List rules  etiquette:
www.re-wrenches.org/etiquette.htm

Check out participant bios:
www.members.re-wrenches.org

___
List sponsored by Home Power magazine

List Address: RE-wrenches@lists.re-wrenches.org

Options  settings:
http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org

List-Archive: http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org

List rules  etiquette:
www.re-wrenches.org/etiquette.htm

Check out participant bios:
www.members.re-wrenches.org