Re: relax-users Digest, Vol 116, Issue 38

2016-10-01 Thread Edward d'Auvergne
On 1 October 2016 at 20:14, Mahdi, Sam  wrote:
> Hi Edward,
>
> Oh ok. Thank you for your help, I was able to resolve the problems I had
> with both proteins, and now they are both running. Since there is symmetry
> within the dimer, both chain A and chain B will give me the same S^2 results
> correct?

Hi Sam,

That depends.  If you superimpose A and B and have an RMSD of
0.0, then the S2 values will be identical.  But if
the docking software changed the monomer structures slightly so the
RMSD is not exactly zero, then the S2 values will be slightly
different for some residues.  You can use relax to superimpose
structures and determine the RMSD to very high precision, if you like,
but I'll leave that to you as a learning exercise ;)

Regards,

Edward

___
relax (http://www.nmr-relax.com)

This is the relax-users mailing list
relax-users@gna.org

To unsubscribe from this list, get a password
reminder, or change your subscription options,
visit the list information page at
https://mail.gna.org/listinfo/relax-users


Re: relax-users Digest, Vol 116, Issue 38

2016-10-01 Thread Mahdi, Sam
Hi Edward,

Oh ok. Thank you for your help, I was able to resolve the problems I had
with both proteins, and now they are both running. Since there is symmetry
within the dimer, both chain A and chain B will give me the same S^2
results correct?

Sincerely,
Sam

On Sat, Oct 1, 2016 at 2:21 AM, Edward d'Auvergne 
wrote:

> On 30 September 2016 at 23:42, Mahdi, Sam 
> wrote:
> > Hi Edward,
> >
> > So when I ran it as read_mol=0, it gave me the same error. But it worked
> > once I changed it to read_mol=1. I thought mol=0 was for set A and mol=1
> was
> > for set B?
>
> Sorry, I just remembered that the molecule numbering starts from 1.
> So read_mol=1 gives chain ID A and read_mol=2 gives chain ID B.  I
> should add a check for this argument.
>
> Regards,
>
> Edward
>
___
relax (http://www.nmr-relax.com)

This is the relax-users mailing list
relax-users@gna.org

To unsubscribe from this list, get a password
reminder, or change your subscription options,
visit the list information page at
https://mail.gna.org/listinfo/relax-users


Re: relax-users Digest, Vol 116, Issue 38

2016-10-01 Thread Edward d'Auvergne
On 30 September 2016 at 23:42, Mahdi, Sam  wrote:
> Hi Edward,
>
> So when I ran it as read_mol=0, it gave me the same error. But it worked
> once I changed it to read_mol=1. I thought mol=0 was for set A and mol=1 was
> for set B?

Sorry, I just remembered that the molecule numbering starts from 1.
So read_mol=1 gives chain ID A and read_mol=2 gives chain ID B.  I
should add a check for this argument.

Regards,

Edward

___
relax (http://www.nmr-relax.com)

This is the relax-users mailing list
relax-users@gna.org

To unsubscribe from this list, get a password
reminder, or change your subscription options,
visit the list information page at
https://mail.gna.org/listinfo/relax-users