While the topic of tone remotes came up, I have a question about 
configuration.

I help to maintain a remote base system in my town.  The radio is a 
Motorola DeskTrac remote base.  Connected to this are three CPI TR-10 
tone remotes.  One of the tone remotes is at the Desktrac location, and 
the other two are on two separate cable pairs to different locations.  
I'm not quite sure as to how the three circuits should connect 
together.  CPI documents state that one should be in the 600 ohm 
terminated mode and the other two in the 5000 ohm mode, but this is when 
the three are on the same phone line.  This does not work well, so I had 
to put them all in the 600 ohm mode to make them work properly with no 
ground hums.  What I would like to do is put 600:600 ohm isolation 
transformers on each of the remote circuits to isolate them and 
hopefully eliminate the little ground hum I still have.

I'm wondering if there is a better way.

Joe