Had the same exact thing happen on a Motorla Mitrek setup, asked the
guys here, they said turn up the power a little so the internal TX RX
filters would work better. Cranked it up from 25 to 30W and it did the
trick.
I have heard the GE's are just a finicky.
Scott NA4IT
--- In Repeater-Builder@yahoogroups.com, Dennis Carpenter
[EMAIL PROTECTED] wrote:
I have a Mastr II VHF mobile conversion w/Link rlc1+ controller,
preamp at the duplexer and ts64 decoder board. All has worked well
fer a few years now. Recently there has been a steady tone (squeel)
around 1000hz heard on the repeater. It as all problems comes and
goes. It at first could be heard only when a carrier was being
rec'd. When the rec'd signal dropped so did the tone. Nothing heard
on tx hangtime.
This morning though it remained on after the rec'd signal dropped,
all the way until the R
rptr TX dropped. It would happen this morning about 50% of the time.
This was first time we've heard it in a few days.
Any ideas what to look fer first?? Thought the trouble was the
rec'vr but after this morning not to sure.
As always thanks in advance,
Dennis ki5fw
Lauderdale Repeater group w5LRG
444.500 w5LRG/R
146.970 ki5fw/R pl100hz
Lauderdale county, MS