PostDoc position open on the Material Science Powder Diffraction beamline of the ALBA synchrotron (Spain)

2020-03-05 Thread Fauth Francois

Dear all

This email to inform that a PostDoc postion is now open on the BL04-MSPD 
beamline of the ALBA synchrotron located in the Barcelona area, Spain


Further info can be found in https://public.cells.es/jobs/#!/jobs

Application submission should be performed through the above link  
exclusively.


--

Dr. FAUTH Francois  Experiments Division
CELLS - ALBAhttp://www.cells.es
Carrer de la Llum 2-26
08290 Cerdanyola del Vallès, Barcelona (Spain)
Phone/Fax +34 93 592 4325 / +34 93 592 4301

++
Please do NOT attach files to the whole list 
Send commands to  eg: HELP as the subject with no body text
The Rietveld_L list archive is on http://www.mail-archive.com/rietveld_l@ill.fr/
++



Post Doc position on Material Science Powder Diffraction beamline of ALBA synchrotron

2018-02-19 Thread Fauth Francois

Dear all

Since Rietveld refinement and Powder Diffraction have a direct and 
natural link, I take the opportunity of the list to inform there is 
presently a post doctoral position open at the ALBA synchrotron on the 
Material Science Powder Diffraction beamline (MSPD)


To reach the position notice go to http://www.cells.es/en -> JobOffers

Please use the web indicated channel "Apply for this Job" button to 
apply (do not send application to me, they will not be considered)


Cheers from Barcelona

--

Dr. FAUTH Francois  Experiments Division
CELLS - ALBAhttp://www.cells.es
Carrer de la Llum 2-26
08290 Cerdanyola del Vallès, Barcelona (Spain)
Phone/Fax +34 93 592 4325 / +34 93 592 4301

++
Please do NOT attach files to the whole list 
Send commands to  eg: HELP as the subject with no body text
The Rietveld_L list archive is on http://www.mail-archive.com/rietveld_l@ill.fr/
++



Re: mark-tubes

2017-11-08 Thread Fauth Francois

Hi

Hilgenberg GmBh appears to be the major supplier of glass capillaries. 
There are some companies purchasing form Hilgenberg in great quantities 
(so to benefit of a light discount) and reselling them in 25 piece 
units...but at the end the original supplier is the same.


Regarding properties, you can find absorption coefficients and softening 
temperatures  of each of your mentioned glass in

http://www.hilgenberg-gmbh.de/en/products/test-tubes/sample-tubes.

Quartz tubes are more expensive and are generally used for high 
temperatures.
Then at RT  there is the possibility to use Kapton tubes but hey do not 
have funnels which is very convenient for filling.


Please feedback to the community if you  discover an alternative supplier.

Cheers from Barcelona

Dr. FAUTH Francois  Experiments Division
CELLS - ALBAhttp://www.cells.es
Carrer de la Llum 2-26
08290 Cerdanyola del Vallès, Barcelona (Spain)
Phone/Fax +34 93 592 4325 / +34 93 592 4301

On 11/8/2017 7:23 AM, Davide Levy wrote:


Hi,

Which are the best mark-tubes for diffraction? Borosilicates glass, 
soda-lime glass, Lindeman glass or quartz?

which is the best brand?

Thank you

Davide



++
Please do NOT attach files to the whole list 
Send commands to  eg: HELP as the subject with no body text
The Rietveld_L list archive is on http://www.mail-archive.com/rietveld_l@ill.fr/
++



++
Please do NOT attach files to the whole list 
Send commands to  eg: HELP as the subject with no body text
The Rietveld_L list archive is on http://www.mail-archive.com/rietveld_l@ill.fr/
++



Re: Cyberstar hot air blowers

2015-07-03 Thread Fauth Francois

Hi

Complaining about the cost of small French companies (or even large 
international companies :-) is not appropriate on the Rietveld list.




in particular in this case since the air blower designed by the "small" 
french company  can only be purchased through  the 'big" company which 
got the license



Dr. FAUTH Francois  Experiments Division
CELLS - ALBAhttp://www.cells.es
Carretera BP 1413 Km 3.3
08290 Cerdanyola del Vallès, Barcelona (Spain)
Phone/Fax +34 93 592 4325 / +34 93 592 4301

On 7/3/2015 11:17 AM, Alan Hewat wrote:

I think Simon is simply asking for recommendations of hot air blowers.

Complaining about the cost of small French companies (or even large 
international companies :-) is not appropriate on the Rietveld list.


Alan.

On 3 July 2015 at 10:38, SAJ Kimber <mailto:kim...@esrf.fr>> wrote:


Dear All,

Sorry not a direct Rietveld question, but I hope somebody can
help  : )

We often use high temperature (RT - 1000 C) gas blowers at ESRF
for their flexibility and low background. Those made by Cyberstar
seem to have become prohibitively expensive. Does anyone know of a
competing supplier?

best wishes,

Simon

-- 
-

Dr. Simon A.J. Kimber
European Synchrotron Radiation Facility,
71 Avenue des Martyrs,
38000 Grenoble,
France.
0033 (0)47688 2773

++
Please do NOT attach files to the whole list

Send commands to mailto:lists...@ill.fr>> eg:
HELP as the subject with no body text
The Rietveld_L list archive is on
http://www.mail-archive.com/rietveld_l@ill.fr/
++





--
__
*   Dr Alan Hewat, NeutronOptics, Grenoble, FRANCE *
 +33.476.98.41.68
http://www.NeutronOptics.com/hewat
__


++
Please do NOT attach files to the whole list 
Send commands to  eg: HELP as the subject with no body text
The Rietveld_L list archive is on http://www.mail-archive.com/rietveld_l@ill.fr/
++



PostDoctoral position on the Powder Diffraction beamline at ALBA synchrotron

2015-05-25 Thread Fauth Francois

Dear Rietvelders

I just want to inform on  the following open position at ALBA synchrotron

Postdoctoral Position at the Materials Science and Powder Diffraction 
Beamline

https://www.cells.es/old/Jobs/JobOffers/JobOffers/ViewJob?job_id=192

If the direct link does not work, go to www.cells.es and look for the 
_Job Candidates link.
If interested in applying, please follow the instructions given on the 
web page.


Note as well an actual  open PostDoc position for EXAFS/XANES beamline

Cheers from Barcelona,
Francois

--
Dr. FAUTH Francois  Experiments Division
CELLS - ALBAhttp://www.cells.es
Carretera BP 1413 Km 3.3
08290 Cerdanyola del Vallès, Barcelona (Spain)
Phone/Fax +34 93 592 4325 / +34 93 592 4301

++
Please do NOT attach files to the whole list 
Send commands to  eg: HELP as the subject with no body text
The Rietveld_L list archive is on http://www.mail-archive.com/rietveld_l@ill.fr/
++



Post doc position at ALBA synchrotron

2015-03-02 Thread Fauth Francois

Hi Riervelders

This email to inform about the open Post Doctoral position on the 
Material Science and Powder Diffraction beamline of the ALBA synchrotron 
located in the Barcelona area.


More details on ALBA Jobs web site, or directly 
http://www.cells.es/old/Jobs/JobOffers/JobOffers/ViewJob?job_id=186


Cheers from Barcelona


--
Dr. FAUTH Francois  Experiments Division
CELLS - ALBAhttp://www.cells.es
Carretera BP 1413 Km 3.3
08290 Cerdanyola del Vallès, Barcelona (Spain)
Phone/Fax +34 93 592 4325 / +34 93 592 4301

++
Please do NOT attach files to the whole list 
Send commands to  eg: HELP as the subject with no body text
The Rietveld_L list archive is on http://www.mail-archive.com/rietveld_l@ill.fr/
++



Re: Intensity issue with synchrotron data

2015-01-15 Thread Fauth Francois

Hi


and..what you do with the errors for weighing the observations?


Divide by the same factor  as the intensities.  Here it is assumed the 
esd have been already calculated


 Francois

++
Please do NOT attach files to the whole list 
Send commands to  eg: HELP as the subject with no body text
The Rietveld_L list archive is on http://www.mail-archive.com/rietveld_l@ill.fr/
++



Re: Intensity issue with synchrotron data

2015-01-15 Thread Fauth Francois

Dear Marco

Two possible origins to your problems

1- the  data format of the input file your are using for your refinement 
does not allow counts more than 10^6, This is typically the case  with 
GSAS  input file format

Here at ALBA, as you suggested, we divide all the intensities by factor 10

2- as previously suggested, you might have a problem of detection non 
linearity and/or saturation. But since you measured at SLS liklely using 
the MYTHEN detector able to accept extremely high count rates , I do not 
think this is the problem


Francois

Dr. FAUTH Francois  Experiments Division
CELLS - ALBAhttp://www.cells.es
Carretera BP 1413 Km 3.3
08290 Cerdanyola del Vallès, Barcelona (Spain)
Phone/Fax +34 93 592 4325 / +34 93 592 4301

On 1/15/2015 8:49 AM, Marco Taddei wrote:

Dear Rietvelders,

Yesterday I was dealing with the refinement of silicon collected with 
synchrotron radiation at the MS beamline at SLS. The intensity of many 
reflections exceeds 10^6 counts, in some cases even reaching almost 
10^7 counts.
I noticed that the peaks exceeding 10^6 counts were kind of truncated, 
with the consequence that the pattern looked quite different from what 
it was supposed to be.
Since I always treated data from home diffractometers so far, I never 
came across such an issue.
My idea was to just divide all of the intensities by 10, so as to 
preserve the relative intensities and the signal/background ratio, is 
this a possible solution to the issue? Or there are maybe some other 
ways to deal with it?


Thanks in advance.

Best,
Marco




++
Please do NOT attach files to the whole list 
Send commands to  eg: HELP as the subject with no body text
The Rietveld_L list archive is on http://www.mail-archive.com/rietveld_l@ill.fr/
++



Scientist position on the Powder Diffraction beamline at ALBA synchrotron

2014-11-14 Thread Fauth Francois

Dear Rietvelders

I just want to inform on  the following open position at ALBA synchrotron

Beamline Scientist at the Materials Science and Powder Diffraction Beamline
https://www.cells.es/old/Jobs/JobOffers/JobOffers/ViewJob?job_id=173

If the direct link does not work, go to www.cells.es and look for the 
_Job Candidates link.


If interested in applying, please follow the instructions given on the 
web page.


Cheers from Barcelona,
Francois

--
Dr. FAUTH Francois  Experiments Division
CELLS - ALBAhttp://www.cells.es
Carretera BP 1413 Km 3.3
08290 Cerdanyola del Vallès, Barcelona (Spain)
Phone/Fax +34 93 592 4325 / +34 93 592 4301

++
Please do NOT attach files to the whole list 
Send commands to  eg: HELP as the subject with no body text
The Rietveld_L list archive is on http://www.mail-archive.com/rietveld_l@ill.fr/
++



Proposals for beamtime at ALBA Powder Diffraction bemaline (Barcelona)

2013-10-29 Thread Fauth Francois

Dear Rietvelder

In case you miss the information, a call for proposal is open at ALBA 
synchrotron (Barcelona) until November 4th.

This call concerns beamtime in the May - December 2104 period.

Beamline  of interest for Rietvelders  is surely the Material Science 
Powder Diffraction one dedicated to High Angular Resolution Powder 
Diffraction and High Pressure/Micro diffraction.


More information can be found on ALBA-CELLS website http://www.cells.es/

Non Spanish user groups  can by fully funded via so-called CALYPSO 
fundings.  To benefit of this program main proposer must be affiliated 
in an EU member country or one of the affiliated country (Switzerland, 
Israel, Norway, Iceland, Liechtenstein,Turkey, Croatia, the Former 
Yugoslav Republic of Macedonia and Serbia, Albania, Montenegro,Bosnia & 
Herzegovina, Faroe Islands, Republic of Moldova)


Cheers from Barcelona

--
Dr. FAUTH Francois  Experiments Division
CELLS - ALBAhttp://www.cells.es
Carretera BP 1413 Km 3.3
08290 Cerdanyola del Vallès, Barcelona (Spain)
Phone/Fax +34 93 592 4325 / +34 93 592 4301

++
Please do NOT attach files to the whole list 
Send commands to  eg: HELP as the subject with no body text
The Rietveld_L list archive is on http://www.mail-archive.com/rietveld_l@ill.fr/
++



Post Doc position on the Material Science and Powder Diffraction beamline at synchrotron ALBA, Barcelona

2013-09-17 Thread Fauth Francois

Dear Rietvelders

I want to draw your attention on the opening of a 3 years post doctoral 
position on the  Material Science and Powder Diffraction beamline at 
synchrotron ALBA, Barcelona
The advertisement can be found on the ALBA-CELLS  web site 
http://www.cells.es under Jobs tab or directly 
http://www.cells.es/Jobs/JobOffers/ViewJob?job_id=146


Feel free to diffuse this information.

Cheers from Barcelona

--
Dr. FAUTH Francois  Experiments Division
CELLS - ALBAhttp://www.cells.es
Carretera BP 1413 Km 3.3
08290 Cerdanyola del Vallès, Barcelona (Spain)
Phone/Fax +34 93 592 4325 / +34 93 592 4301

++
Please do NOT attach files to the whole list 
Send commands to  eg: HELP as the subject with no body text
The Rietveld_L list archive is on http://www.mail-archive.com/rietveld_l@ill.fr/
++



Re: fit2d calibration

2007-07-19 Thread Fauth Francois


Dear John,

Not really Rietveld related but well ;-)

Since you used Silver Behenate, you have to create a "Calibration 
file"containing the d-spacing (in Agstroem) of the rings you will use for 
calibration.
Assume you have collected the 3 first rings of Silver Behenate,   you will 
create a file containing the three following lines,

58.380
29.190
19.40

Let's name this file  AgBeh_1-3.cal

Then when launching Fit2d, you choose first the "Powder Diffraction"menu, 
Load your file using the "Input" button, then go to "Calibrant" menu, 
Choose the "User Defined"option. There you select your file AgBeh_1-3.cal 
(check that the directory is properly given).
At this stage, you will reach a menu where you give the pixel size of your 
detector, the wavelength, and starting values for the refined parameters 
(sample to detector distance, tilts angles), and the parameters you want to 
refined.
Then you have to "click" some points on the first ring of your data (by 
first, I mean the ring corresponding to the fisrt d-spacing given in your 
Calibrant file)


If everything was OK (not too bad starting values), you should get good 
refined values  : generally sample to detector distance, beam center values 
and, if you have choosen this option - tilt values.

This is these values  which will be used to further process you SAXS data.

Hope it helps.
Do not hesistate to contact me dircetly if you need further help.

Francois

At 10:17 19/07/2007 +, you wrote:

Dear all,
I've got some SAXS data that needs looking at, but i've
forgotten how to calibrate "fit2d" to give the proper
d-spacing. Any help most welcome!!

Silver behenate was the calibrant.

John O'Callaghan





John O'Callaghan,
Materials and Supercritical Fluid Section,
Chemistry Dept.,
University College Cork,
Ireland.


--
Discover the new Windows Vista Learn more!


Dr. Fauth Francois
BM16-CRG/Consorci Laboratori Llum Sincrotro (LLS)
c/o European Synchrotron Radiation Facility (ESRF)
BP 220 / 6, Rue Jules Horowitz
F-38043 Grenoble,France

tel: (+33) (0)4 76 88 23 24
fax: (+33) (0)4 76 88  27 07