Re: [atlas] Probe v1 disconnecting every 2 hours

2019-01-30 Thread Philip Homburg
On 2019/01/30 19:49 , Cornelius Keck wrote:
> I'm wondering, in case the probe continues to have issues, is there a
> way to get a replacement?

Yes, you can always ask for a replacement. We are still quite a bit
behind in shipping probes because the transition from v3 to v4 probes
was quite a bit of work.

> Or, come to think of it, replace the probe
> with some code on smallish hardware, like a Raspberry Pi?

We are looking into this. There is no timeline, or even a commitment to
provide this option. But we are actively preparing for a pilot.

Philip



Re: [atlas] Probe v1 disconnecting every 2 hours

2019-01-30 Thread Cornelius Keck
Mine has been acting up lately as well. Changed the router (no dice), 
ethernet cable (likewise), then the power supply, which improved matters 
quite some until earlier today. Right now it's still down, despite the 
router it is hooked up to functioning as it should. It has been up close 
to eight years. Going to change routers again tonight when I get home (5 
static IPs, 5 routers, so there are options).


I'm wondering, in case the probe continues to have issues, is there a 
way to get a replacement? Or, come to think of it, replace the probe 
with some code on smallish hardware, like a Raspberry Pi?


Thx!

-Cornelius

Gert Doering wrote:

Hi,

On Wed, Jan 30, 2019 at 09:04:45AM -0800, Christopher Morrow wrote:

maybe the flash card is going sad? and just doing the proscribed :"get new
card, power down, swap card, wait for 30 mins, profit" will make things
happy again?
worse case it costs you a 4g flash card :)


v1 probes do not have USB flash yet - which is good, because that
particular annoyance doesn't happen :-)

OTOH, it might be just dieing of old age, after like 8-9 years.

Gert Doering
-- NetMaster





Re: [atlas] Probe v1 disconnecting every 2 hours

2019-01-30 Thread Christopher Morrow
On Wed, Jan 30, 2019 at 9:16 AM Gert Doering  wrote:

> Hi,
>
> On Wed, Jan 30, 2019 at 09:04:45AM -0800, Christopher Morrow wrote:
> > maybe the flash card is going sad? and just doing the proscribed :"get
> new
> > card, power down, swap card, wait for 30 mins, profit" will make things
> > happy again?
> > worse case it costs you a 4g flash card :)
>
> v1 probes do not have USB flash yet - which is good, because that
> particular annoyance doesn't happen :-)
>
>
oh, bummer :( also good... sort of :)


> OTOH, it might be just dieing of old age, after like 8-9 years.
>
> Gert Doering
> -- NetMaster
> --
> have you enabled IPv6 on something today...?
>
> SpaceNet AG  Vorstand: Sebastian v. Bomhard, Michael
> Emmer
> Joseph-Dollinger-Bogen 14Aufsichtsratsvors.: A. Grundner-Culemann
> D-80807 Muenchen HRB: 136055 (AG Muenchen)
> Tel: +49 (0)89/32356-444 USt-IdNr.: DE813185279
>


Re: [atlas] Probe v1 disconnecting every 2 hours

2019-01-30 Thread Gert Doering
Hi,

On Wed, Jan 30, 2019 at 09:04:45AM -0800, Christopher Morrow wrote:
> maybe the flash card is going sad? and just doing the proscribed :"get new
> card, power down, swap card, wait for 30 mins, profit" will make things
> happy again?
> worse case it costs you a 4g flash card :)

v1 probes do not have USB flash yet - which is good, because that 
particular annoyance doesn't happen :-)

OTOH, it might be just dieing of old age, after like 8-9 years.

Gert Doering
-- NetMaster
-- 
have you enabled IPv6 on something today...?

SpaceNet AG  Vorstand: Sebastian v. Bomhard, Michael Emmer
Joseph-Dollinger-Bogen 14Aufsichtsratsvors.: A. Grundner-Culemann
D-80807 Muenchen HRB: 136055 (AG Muenchen)
Tel: +49 (0)89/32356-444 USt-IdNr.: DE813185279


signature.asc
Description: PGP signature


Re: [atlas] Probe v1 disconnecting every 2 hours

2019-01-30 Thread Christopher Morrow
maybe the flash card is going sad? and just doing the proscribed :"get new
card, power down, swap card, wait for 30 mins, profit" will make things
happy again?
worse case it costs you a 4g flash card :)

On Wed, Jan 30, 2019 at 7:51 AM Hugh Saunders  wrote:

> Hey All,
> My probe v1 (id:65[1]) has started disconnecting roughly every 2 hours. I
> read a previous post[2] that said this may be related to power, so changed
> the USB power supply to one that provides 1A (the FAQ says the need 500ma)
> but no improvement. I don't notice connectivity issues every couple of
> hours with any other devices on the same switch.
>
> Any suggestions welcome :)
>
> Thanks.
>
> [1] https://atlas.ripe.net/probes/65/
> [2]
> https://www.ripe.net/participate/mail/forum/ripe-atlas/PDI1MDc1YjM1LTA5MTctOGYyNS05MGMzLWM1YmFiZjNmNTY4NEBzb2tvbG92LmV1Lm9yZz4=
>
> --
> Hugh Saunders
>


[atlas] Probe v1 disconnecting every 2 hours

2019-01-30 Thread Hugh Saunders
Hey All,
My probe v1 (id:65[1]) has started disconnecting roughly every 2 hours. I
read a previous post[2] that said this may be related to power, so changed
the USB power supply to one that provides 1A (the FAQ says the need 500ma)
but no improvement. I don't notice connectivity issues every couple of
hours with any other devices on the same switch.

Any suggestions welcome :)

Thanks.

[1] https://atlas.ripe.net/probes/65/
[2]
https://www.ripe.net/participate/mail/forum/ripe-atlas/PDI1MDc1YjM1LTA5MTctOGYyNS05MGMzLWM1YmFiZjNmNTY4NEBzb2tvbG92LmV1Lm9yZz4=

--
Hugh Saunders