What happens if you connect a second computer to the Rivendell machine's
serial port and run minocom on it? Can you see the commands Rivendell is
sending?
Rob
On Wed, 27 May 2015, Joe Panarello wrote:
Hi;
I wonder if anyone has had this problem or could shed some light on the
issue. We are trying to integrate a Broadcast Tools Switcher SRC-16+ to use
on a new Rivendell installation 2.10.3. The problem is that we cannot get
Rivendell to communicate with the switcher.
We are able to talk to the BT-16 via Minicom and can turn on and off all
relays. Using "*0OR01L" = on and "*0OR01F" = off format. We have added the
dialout group to the rd user with "usermod -a -G dialout rd" command.
Additionally we have set the permissions for ttyS0 by "chmod 666
/dev/ttyS0". We have setup the serial port in Rivendell serial port admin
to 9600 8 1 none as requested by the documentation.
I've created a few macro's GO 0 O 0 1! To turn on the #1 relay and GO 0 O 1
0 0! to turn off the relay. Neither do anything, the TX or TR lights on the
BT-16 do not flash as they do with the Minicom. I even tried a macro
"SO *0OR01L!" and still nothing. It seems like we are not communicating at
all through Rivendell.
Any help would be greatly appreciated.
Best
joe
Joe Panarello
WFIT
www.WFIT.org
570.881.7170
___
Rivendell-dev mailing list
Rivendell-dev@lists.rivendellaudio.org